The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Single-photon imager based on a superconducting nanowire delay line
Open accessAbstract
Detecting spatial and temporal information of individual photons is critical to applications in spectroscopy, communication, biological imaging, astronomical observation and quantum-information processing. Here we demonstrate a scalable single-photon imager using a single continuous superconducting nanowire that is not only a single-photon detector but also functions as an efficient microwave delay line. In this context, photon-detection pulses are guided in the nanowire and enable the readout of the position and time of photon-absorption events from the arrival times of the detection pulses at the nanowire's two ends. Experimentally, we slowed down the velocity of pulse propagation to ∼2% of the speed of light in free space. In a 19.7 mm long nanowire that meandered across an area of 286 × 193 μm2, we were able to resolve ∼590 effective pixels with a temporal resolution of 50 ps (full width at half maximum). The nanowire imager presents a scalable approach for high-resolution photon imaging in space and time. A superconducting nanowire acting as a single-photon detector and as a microwave delay line is used to demonstrate an imaging device at the single-photon level with sub-20-µm spatial resolution and 50-ps temporal resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
Cited by
Demonstration of sub-3 ps temporal resolution with a superconducting nanowire single-photon detector
Korzh, B., Zhao, Q.-Y., Allmaras, J. P., Frasca, S., Autry, T. M., Bersin, E. A., Beyer, A. D., Briggs, R. M., Bumble, B., Colangelo, M., et al. (2020) · Nature Photonics · doi:10.1038/s41566-020-0589-x · Cited by 564
Self-citationEsmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
Kilopixel array of superconducting nanowire single-photon detectors
Wollman, E. E., Verma, V. B., Lita, A. E., Farr, W. H., Shaw, M. D., Mirin, R. P., & Woo Nam, S. (2019) · Optics Express · doi:10.1364/oe.27.035279 · Cited by 181
Resolving photon numbers using a superconducting nanowire with impedance-matching taper
Zhu, D., Colangelo, M., Chen, C., Korzh, B. A., Wong, F. N. C., Shaw, M. D., & Berggren, K. K. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c00985 · Cited by 103
Self-citationState readout of a trapped ion qubit using a trap-integrated superconducting photon detector
Todaro, S. L., Verma, V. B., McCormick, K. C., Allcock, D. T. C., Mirin, R. P., Wineland, D. J., Nam, S. W., Wilson, A. C., Leibfried, D., & Slichter, D. H. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.010501 · Cited by 98
Metadata
- Authors
- Zhao, Q.-Y., Zhu, D., Calandri, N., Dane, A. E., McCaughan, A. N., Bellei, F., Wang, H.-Z., Santavicca, D. F., & Berggren, K. K.
- Venue
- Nature Photonics
- Published
- 2017-03-27
- Volume
- 11
- Issue
- 4
- Pages
- 247-251
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2482816894
- Cited by
- 182
- References
- 1
- FWCI
- 11.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.