The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vivo optical molecular imaging and analysis in mice using dorsal window chamber models applied to hypoxia, vasculature and fluorescent reporters
Open accessAbstract
Optical techniques for functional imaging in mice have a number of key advantages over other common imaging modalities such as magnetic resonance imaging, positron emission tomography or computed tomography, including high resolution, low cost and an extensive library of available contrast agents and reporter genes. A major challenge to such work is the limited penetration depth imposed by tissue turbidity. We describe a window chamber technique by which these limitations can be avoided. This facilitates the study of a wide range of processes, with potential endpoints including longitudinal gene expression, vascular remodeling and angiogenesis, and tumor growth and invasion. We further describe several quantitative imaging and analysis techniques for characterizing in vivo fluorescence properties and functional endpoints, including vascular morphology and oxygenation. The procedure takes ∼2 h to complete, plus up to several weeks for tumor growth and treatment procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cao, Y., Li, C.-Y., Moeller, B. J., Yu, D., Zhao, Y., Dreher, M. R., Shan, S., & Dewhirst, M. W. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-4553 · Cited by 92
Self-citation
Cited by
Shadrin, I. Y., Allen, B. W., Qian, Y., Jackman, C. P., Carlson, A. L., Juhas, M. E., & Bursac, N. (2017) · Nature Communications · doi:10.1038/s41467-017-01946-x · Cited by 420
Boosting anti-PD-1 therapy with metformin-loaded macrophage-derived microparticles
Wei, Z., Zhang, X., Yong, T., Bie, N., Zhan, G., Li, X., Liang, Q., Li, J., Yu, J., Huang, G., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20723-x · Cited by 342
Engineering human pluripotent stem cells into a functional skeletal muscle tissue
Rao, L., Qian, Y., Khodabukus, A., Ribar, T., & Bursac, N. (2018) · Nature Communications · doi:10.1038/s41467-017-02636-4 · Cited by 334
Label-free DNA imaging in vivo with stimulated Raman scattering microscopy
Lu, F.-K., Basu, S., Igras, V., Hoang, M. P., Ji, M., Fu, D., Holtom, G. R., Neel, V. A., Freudiger, C. W., Fisher, D. E., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515121112 · Cited by 302
Surgical implantation of an abdominal imaging window for intravital microscopy
Ritsma, L., Steller, E. J. A., Ellenbroek, S. I. J., Kranenburg, O., Borel Rinkes, I. H. M., & van Rheenen, J. (2013) · Nature Protocols · doi:10.1038/nprot.2013.026 · Cited by 279
Metadata
- Authors
- Palmer, G. M., Fontanella, A. N., Shan, S., Hanna, G., Zhang, G., Fraser, C. L., & Dewhirst, M. W.
- Venue
- Nature Protocols
- Published
- 2011-08-18
- Volume
- 6
- Issue
- 9
- Pages
- 1355-1366
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W2073844962
- Cited by
- 168
- References
- 1
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.