Heat-induced radiolabeling and fluorescence labeling of Feraheme nanoparticles for PET/SPECT imaging and flow cytometry
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This protocol describes the heat-induced radiolabeling of Feraheme (FH) nanoparticles for PET/SPECT imaging and labeling of FH nanoparticles with fluorescent Cy5.5 dyes for flow cytometry. Feraheme (FH) nanoparticles (NPs) have been used extensively for treatment of iron anemia (due to their slow release of ionic iron in acidic environments). In addition, injected FH NPs are internalized by monocytes and function as MRI biomarkers for the pathological accumulation of monocytes in disease. We have recently expanded these applications by radiolabeling FH NPs for positron emission tomography (PET) or single-photon emission computed tomography (SPECT) imaging using a heat-induced radiolabeling (HIR) strategy. Imaging FH NPs using PET/SPECT has important advantages over MRI due to lower iron doses and improved quantitation of tissue NP concentrations. HIR of FH NPs leaves the physical and biological properties of the NPs unchanged and allows researchers to build on the extensive knowledge obtained about the pharmacokinetic and safety aspects of FH NPs. In this protocol, we present the step-by-step procedures for heat (120 °C)-induced bonding of three widely employed radiocations (89Zr4+ or 64Cu2+ for PET, and 111In3+ for SPECT) to FH NPs using a chelateless radiocation surface adsorption (RSA) approach. In addition, we describe the conversion of FH carboxyl groups into amines and their reaction with an N-hydroxysuccinimide (NHS) of a Cy5.5 fluorophore. This yields Cy5.5-FH, a fluorescent FH that enables the cells internalizing Cy5.5-FH to be examined using flow cytometry. Finally, we describe procedures for in vivo and ex vivo uptake of Cy5.5-FH by monocytes and for in vivo microPET/CT imaging of HIR-FH NPs. Synthesis of HIR-FH requires experience with working with radioactive cations and can be completed within <4 h. Synthesis of Cy5.5-FH NPs takes ∼17 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jahn, M. R., Andreasen, H. B., Fütterer, S., Nawroth, T., Schünemann, V., Kolb, U., Hofmeister, W., Muñoz, M., Bock, K., Meldal, M., et al. (2011) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2011.03.016 · Cited by 256
Comparative risk of anaphylactic reactions associated With intravenous iron products
Wang, C., Graham, D. J., Kane, R. C., Xie, D., Wernecke, M., Levenson, M., MaCurdy, T. E., Houstoun, M., Ryan, Q., Wong, S., et al. (2015) · JAMA · doi:10.1001/jama.2015.15572 · Cited by 219
Ferumoxytol for treatment of iron deficiency anemia in patients with chronic kidney disease
Coyne, D. W. (2009) · Expert Opinion on Pharmacotherapy · doi:10.1517/14656560903224998 · Cited by 95 · cited 1×
“(b) Four quadrants of dual-wavelength flow cytometry are (1) unlabeled cells, (2) Cy5.”
BackgroundHamilton, B. E., Nesbit, G. M., Dosa, E., Gahramanov, S., Rooney, B., Nesbit, E. G., Raines, J., & Neuwelt, E. A. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5992 · Cited by 63
Maarouf, A., Ferré, J.-C., Zaaraoui, W., Le Troter, A., Bannier, E., Berry, I., Guye, M., Pierot, L., Barillot, C., Pelletier, J., et al. (2016) · Multiple Sclerosis Journal · doi:10.1177/1352458515607649 · Cited by 22
Cited by
Fang, E. F., Hou, Y., Palikaras, K., Adriaanse, B. A., Kerr, J. S., Yang, B., Lautrup, S., Hasan-Olive, M. M., Caponio, D., Dan, X., et al. (2019) · Nature Neuroscience · doi:10.1038/s41593-018-0332-9 · Cited by 1,740
FDA-approved ferumoxytol displays anti-leukaemia efficacy against cells with low ferroportin levels
Trujillo-Alonso, V., Pratt, E. C., Zong, H., Lara-Martinez, A., Kaittanis, C., Rabie, M. O., Longo, V., Becker, M. W., Roboz, G. J., Grimm, J., et al. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0406-1 · Cited by 319
Self-citationAssessing the interactions between radiotherapy and antitumour immunity
Grassberger, C., Ellsworth, S. G., Wilks, M. Q., Keane, F. K., & Loeffler, J. S. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0238-9 · Cited by 244
Self-citationBesenhard, M. O., LaGrow, A. P., Hodzic, A., Kriechbaum, M., Panariello, L., Bais, G., Loizou, K., Damilos, S., Margarida Cruz, M., Thanh, N. T. K., et al. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.125740 · Cited by 233
Advantages and Limitations of Current Techniques for Analyzing the Biodistribution of Nanoparticles
Arms, L., Smith, D. W., Flynn, J., Palmer, W., Martin, A., Woldu, A., & Hua, S. (2018) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.00802 · Cited by 159
Metadata
- Authors
- Yuan, H., Wilks, M. Q., Normandin, M. D., El Fakhri, G., Kaittanis, C., & Josephson, L.
- Venue
- Nature Protocols
- Published
- 2018-01-25
- Volume
- 13
- Issue
- 2
- Pages
- 392-412
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W2785122151
- Cited by
- 52
- References
- 5
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heat-induced radiolabeling and fluorescence labeling of Feraheme nanoparticles for PET/SPECT imaging and flow cytometry. https://app.cochat.ai/papers/10.1038/nprot.2017.133
- The paper
- Yuan, H., Wilks, M. Q., Normandin, M. D., El Fakhri, G., Kaittanis, C., & Josephson, L. (2018). Heat-induced radiolabeling and fluorescence labeling of Feraheme nanoparticles for PET/SPECT imaging and flow cytometry. Nature Protocols. https://doi.org/10.1038/nprot.2017.133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.