Real-time high-resolution mid-infrared optical coherence tomography
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
The potential for improving the penetration depth of optical coherence tomography systems by using light sources with longer wavelengths has been known since the inception of the technique in the early 1990s. Nevertheless, the development of mid-infrared optical coherence tomography has long been challenged by the maturity and fidelity of optical components in this spectral region, resulting in slow acquisition, low sensitivity, and poor axial resolution. In this work, a mid-infrared spectral-domain optical coherence tomography system operating at a central wavelength of 4 µm and an axial resolution of 8.6 µm is demonstrated. The system produces two-dimensional cross-sectional images in real time enabled by a high-brightness 0.9- to 4.7-µm mid-infrared supercontinuum source with a pulse repetition rate of 1 MHz for illumination and broadband upconversion of more than 1-µm bandwidth from 3.58–4.63 µm to 820–865 nm, where a standard 800-nm spectrometer can be used for fast detection. The images produced by the mid-infrared system are compared with those delivered by a state-of-the-art ultra-high-resolution near-infrared optical coherence tomography system operating at 1.3 μm, and the potential applications and samples suited for this technology are discussed. In doing so, the first practical mid-infrared optical coherence tomography system is demonstrated, with immediate applications in real-time non-destructive testing for the inspection of defects and thickness measurements in samples that exhibit strong scattering at shorter wavelengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Refractive index of silicon and germanium and its wavelength and temperature derivatives
Li, H. H. (1980) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555624 · Cited by 863
Room-temperature mid-infrared single-photon spectral imaging
Dam, J. S., Tidemand-Lichtenberg, P., & Pedersen, C. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.231 · Cited by 340
Self-citationIn-vitro tomography and non-destructive imaging at depth of pharmaceutical solid dosage forms
ZEITLER, J., & GLADDEN, L. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.08.012 · Cited by 177
Computational high-resolution optical imaging of the living human retina
Shemonski, N. D., South, F. A., Liu, Y.-Z., Adie, S. G., Carney, P. S., & Boppart, S. A. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.102 · Cited by 174
Swanson, E. A., & Fujimoto, J. G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001638 · Cited by 173
Geometrical representation of sum frequency generation and adiabatic frequency conversion
Suchowski, H., Oron, D., Arie, A., & Silberberg, Y. (2008) · Physical Review A · doi:10.1103/physreva.78.063821 · Cited by 161
High-speed optical coherence tomography by circular interferometric ranging
Siddiqui, M., Nam, A. S., Tozburun, S., Lippok, N., Blatter, C., & Vakoc, B. J. (2018) · Nature Photonics · doi:10.1038/s41566-017-0088-x · Cited by 124
Tunable optical coherence tomography in the infrared range using visible photons
Paterova, A. V., Yang, H., An, C., Kalashnikov, D. A., & Krivitsky, L. A. (2018) · Quantum Science and Technology · doi:10.1088/2058-9565/aab567 · Cited by 116
Non-destructive analysis of tablet coatings with optical coherence tomography
Koller, D. M., Hannesschläger, G., Leitner, M., & Khinast, J. (2011) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2011.06.017 · Cited by 93
Self-citationMid-infrared optical coherence tomography
Colley, C. S., Hebden, J. C., Delpy, D. T., Cambrey, A. D., Brown, R. A., Zibik, E. A., Ng, W. H., Wilson, L. R., & Cockburn, J. W. (2007) · Review of Scientific Instruments · doi:10.1063/1.2821609 · Cited by 81
Israelsen, N. M., Maria, M., Mogensen, M., Bojesen, S., Jensen, M., Hædersdal, M., Podoleanu, A. G., & Bang, O. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.002240 · Cited by 62
Self-citationPrykäri, T., Czajkowski, J., Alarousu, E., & Myllylä, R. A. (2010) · Optical Review · doi:10.1007/s10043-010-0039-y · Cited by 52
Jensen, M., Israelsen, N. M., Maria, M., Feuchter, T., Podoleanu, A. G., & Bang, O. (2018) · Scientific Reports · doi:10.1038/s41598-018-27388-z · Cited by 33
Self-citationOptical coherence tomography for quality assessment of embedded microchannels in alumina ceramic
Su, R., Kirillin, M., Ekberg, P., Roos, A., Sergeeva, E. A., & Mattsson, L. H. (2012) · Optics Express · doi:10.1364/oe.20.004603 · Cited by 30
Research works printed but not linked: 18
- Robles, F. E., Wilson, C., Grant, G. & Wax, A. Molecular imaging true-colour spectroscopic optical coherence tomography. Nat. Photonics 5, 744–747 (2011). · doi:10.1038/nphoton.2011.257
- Targowski, P. & Iwanicka, M. Optical coherence tomography: its role in the non-invasive structural examination and conservation of cultural heritage objects—a review. Appl. Phys. A 106, 265–277 (2012). · doi:10.1007/s00339-011-6687-3
- Stifter, D. Beyond biomedicine: a review of alternative applications and developments for optical coherence tomography. Appl. Phys. B 88, 337–357 (2007). · DOI
- Stifter, D. et al. Investigation of polymer and polymer/fibre composite materials with optical coherence tomography. Meas. Sci. Technol. 19, 074011 (2008). · doi:10.1088/0957-0233/19/7/074011
- Cho, N. H., Jung, U., Kim, S. & Kim, J. Non-destructive inspection methods for LEDs using real-time displaying optical coherence tomography. Sensors 12, 10395–10406 (2012). · doi:10.3390/s120810395
- Czajkowski, J., Prykäri, T., Alarousu, E., Palosaari, J. & Myllylä, R. Optical coherence tomography as a method of quality inspection for printed electronics products. Opt. Rev. 17, 257–262 (2010). · doi:10.1007/s10043-010-0045-0
- Cheung, C. S., Daniel, J. M. O., Tokurakawa, M., Clarkson, W. A. & Liang, H. High resolution Fourier domain optical coherence tomography in the 2 μm wavelength range using a broadband supercontinuum source. Opt. Express 23, 1992–2001 (2015). · doi:10.1364/oe.23.001992
- Cheung, C. S., Daniel, J. M. O., Tokurakawa, M., Clarkson, W. A. & Liang, H. Optical coherence tomography in the 2-μm wavelength regime for paint and other high opacity materials. Opt. Lett. 39, 6509–6512 (2014). · doi:10.1364/ol.39.006509
- Sharma, U., Chang, E. W. & Yun, S. H. Long-wavelength optical coherence tomography at 1.7 μm for enhanced imaging depth. Opt. Express 16, 19712–19723 (2008). · DOI
- Ishida, S. & Nishizawa, N. Quantitative comparison of contrast and imaging depth of ultrahigh-resolution optical coherence tomography images in 800–1700 nm wavelength region. Biomed. Opt. Express 3, 282–294 (2012). · doi:10.1364/boe.3.000282
- Su, R. et al. Perspectives of mid-infrared optical coherence tomography for inspection and micrometrology of industrial ceramics. Opt. Express 22, 15804–15819 (2014). · doi:10.1364/oe.22.015804
- Colley, C. S et al. Mid-infrared optical coherence tomography: application in tissue engineering. In Biomedical Topical Meeting 2006 (OSA, Fort Lauderdale, 2006) http://www.osa.org/osaorg/media/osa.media/Meetings/Archives/2006/biomed/BIOMED_2006_Final_Archive.pdf. · doi:10.1364/bio.2006.we8
- Varnell, D., Zheng, M. C., Chow, M. & Gmachl, C. Spectroscopy and imaging using a mid-IR quantum cascade optical coherence tomography (OCT) system. In CLEO: Applications and Technology 2016 (OSA, San Jose, 2016). · doi:10.1364/cleo_at.2016.atu1j.7
- Petersen, C. R., Moselund, P. M., Huot, L., Hooper, L. & Bang, O. Towards a table-top synchrotron based on supercontinuum generation. Infrared Phys. Technol. 91, 182–186 (2018). · doi:10.1016/j.infrared.2018.04.008
- Pedersen, C., Karamehmedović, E., Dam, J. S. & Tidemand-Lichtenberg, P. Enhanced 2D-image upconversion using solid-state lasers. Opt. Express 17, 20885–20890 (2009). · doi:10.1364/oe.17.020885
- Su, R., Chang, E., Ekberg, P., Yun S. & Mattsson L. Enhancement of probing depth and measurement accuracy of optical coherence tomography for metrology of multi-layered ceramics. In Proc. 1st International Symposium on Optical Coherence Tomography for Non-Destructive Testing 71–73 (Linz, Austria, 2013) http://www.diva-portal.org/smash/record.jsf?dswid=4763&pid=diva2%3A662817&c=81&searchType=SIMPLE&language=en&query=optical+coherence+tomography+&af=%5B%5D&aq=%5B%5B%5D%5D&aq2=%5B%5B%5D%5D&aqe=%5B%5D&noOfRows=250&sortOrder=author_sort_asc&sortOrder2=title_sort_asc&onlyFullText=false&sf=all.
- Gao, S. M., Yang, C. X. & Jin, G. F. Flat broad-band wavelength conversion based on sinusoidally chirped optical superlattices in lithium niobate. IEEE Photonics Technol. Lett. 16, 557–559 (2004). · doi:10.1109/lpt.2003.823102
- Makita, S., Fabritius, T. & Yasuno, Y. Full-range, high-speed, high-resolution 1-µm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye. Opt. Express 16, 8406–8420 (2008). · doi:10.1364/oe.16.008406
Cited by
Phase Retrieval in Terahertz Time-Domain Measurements: a 'how to' Tutorial
Jepsen, P. U. (2019) · Journal of Infrared, Millimeter and Terahertz Waves · doi:10.1007/s10762-019-00578-0 · Cited by 114
Metadata
- Authors
- Israelsen, N. M., Petersen, C. R., Barh, A., Jain, D., Jensen, M., Hannesschläger, G., Tidemand-Lichtenberg, P., Pedersen, C., Podoleanu, A., & Bang, O.
- Venue
- Light: Science & Applications
- Published
- 2019-01-23
- Volume
- 8
- Issue
- 1
- Pages
- 11-11
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W2897340379
- Cited by
- 318
- References
- 17
- FWCI
- 13.18
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.