The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A new strategy for the fabrication of a flexible and highly sensitive capacitive pressure sensor
Open accessAbstract
The development of flexible capacitive pressure sensors has wide application prospects in the fields of electronic skin and intelligent wearable electronic devices, but it is still a great challenge to fabricate capacitive sensors with high sensitivity. Few reports have considered the use of interdigital electrode structures to improve the sensitivity of capacitive pressure sensors. In this work, a new strategy for the fabrication of a high-performance capacitive flexible pressure sensor based on MXene/polyvinylpyrrolidone (PVP) by an interdigital electrode is reported. By increasing the number of interdigital electrodes and selecting the appropriate dielectric layer, the sensitivity of the capacitive sensor can be improved. The capacitive sensor based on MXene/PVP here has a high sensitivity (~1.25 kPa−1), low detection limit (~0.6 Pa), wide sensing range (up to 294 kPa), fast response and recovery times (~30/15 ms) and mechanical stability of 10000 cycles. The presented sensor here can be used for various pressure detection applications, such as finger pressing, wrist pulse measuring, breathing, swallowing and speech recognition. This work provides a new method of using interdigital electrodes to fabricate a highly sensitive capacitive sensor with very promising application prospects in flexible sensors and wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dendritic Nanostructured Waste Copper Wires for High-Energy Alkaline Battery
Chodankar, N. R., Ji, S.-H., Han, Y.-K., & Kim, D.-H. (2020) · Nano-Micro Letters · doi:10.1007/s40820-019-0337-2 · Cited by 769
Chen, W., & Yan, X. (2020) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2019.11.010 · Cited by 481
A Bioresorbable Dynamic Pressure Sensor for Cardiovascular Postoperative Care
Ouyang, H., Li, Z., Gu, M., Hu, Y., Xu, L., Jiang, D., Cheng, S., Zou, Y., Deng, Y., Shi, B., et al. (2021) · Advanced Materials · doi:10.1002/adma.202102302 · Cited by 160
Cited by
Recent Advances in Flexible Pressure Sensors Based on MXene Materials
Qin, R., Nong, J., Wang, K., Liu, Y., Zhou, S., Hu, M., Zhao, H., & Shan, G. (2024) · Advanced Materials · doi:10.1002/adma.202312761 · Cited by 416
Self-citationYuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149926 · Cited by 180
MXenes for wearable pressure sensing: Progress and prospects in human motion detection
Kong, X., Fan, C., Liao, K., Zhang, W., & Xiong, H. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.01.086 · Cited by 7
Metadata
- Authors
- Qin, R., Hu, M., Li, X., Liang, T., Tan, H., Liu, J., & Shan, G.
- Venue
- Microsystems & Nanoengineering
- Published
- 2021-11-30
- Volume
- 7
- Issue
- 1
- Pages
- 100-100
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W3216563480
- Cited by
- 164
- References
- 3
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new strategy for the fabrication of a flexible and highly sensitive capacitive pressure sensor. https://app.cochat.ai/papers/10.1038/s41378-021-00327-1
- The paper
- Qin, R., Hu, M., Li, X., Liang, T., Tan, H., Liu, J., & Shan, G. (2021). A new strategy for the fabrication of a flexible and highly sensitive capacitive pressure sensor. Microsystems & Nanoengineering. https://doi.org/10.1038/s41378-021-00327-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.