Cited by 160Advanced Sensor and Energy Harvesting MaterialsNon-Invasive Vital Sign Monitoringbiodegradable polymer synthesis and properties

A Bioresorbable Dynamic Pressure Sensor for Cardiovascular Postoperative Care

Ouyang, Han, Li, Zhe, Gu, Min, Hu, Yiran, Xu, Lingling, Jiang, Dongjie, Cheng, Sijing, Zou, Yang +6 more·2021·Advanced Materials

Abstract

Bioresorbable electronics that can be absorbed and become part of the organism after their service life are a new trend to avoid secondary invasive surgery. However, the material limitation is a significant challenge. There are fewer biodegradable materials with pressure‐sensitive properties. Here, a pressure sensor based on the triboelectric effect between bioabsorbable materials is reported. This effect is available in almost all materials. The bioresorbable triboelectric sensor (BTS) can directly convert ambient pressure changes into electrical signals. This device successfully identifies abnormal vascular occlusion events in large animals (dogs). The service life of the BTS reaches 5 days with a high service efficiency (5.95%). The BTS offers excellent sensitivity (11 mV mmHg−1), linearity (R2 = 0.993), and good durability (450 000 cycles). The antibacterial bioresorbable materials (poly(lactic acid)–(chitosan 4%)) for the BTS can achieve 99% sterilization. Triboelectric devices are expected to be applied in postoperative care as bioresorbable electronics.

Integrity signals

Registry

Crossref · 10.1002/adma.202102302

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ouyang, H., Li, Z., Gu, M., Hu, Y., Xu, L., Jiang, D., Cheng, S., Zou, Y., Deng, Y., Shi, B., Hua, W., Fan, Y., Li, Z., & Wang, Z.
Affiliations
  • Chinese Academy of Sciences (CN)
  • Beijing Institute of Technology (CN)
  • Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
  • Beihang University (CN)
  • CAS Center for Excellence in Nanoscience Beijing Key Laboratory of Micro‐Nano Energy and Sensor Beijing Institute of Nanoenergy and Nanosystems Chinese Academy of Sciences Beijing 100083 China
Corresponding author
  • Hua, Wei
  • Fan, Yubo
  • Li, Zhou
Venue
Advanced Materials
Publisher
Wiley
Published
2021-08-08
Volume
33
Issue
39
Pages
e2102302-e2102302
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3192693634
Cited by
160
References
44
Citations by year
2026: 15 · 2025: 31 · 2024: 36 · 2023: 43 · 2022: 31 · 2021: 4
FWCI
8.66
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (61875015, 62004010, U20A20390, 11827803)
  • China Postdoctoral Science Foundation (2019M660410)
  • Natural Science Foundation of Beijing Municipality (JQ20038)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
Keywords
bioresorbable electronics, bioresorbable materials, postoperative care, polylactic acid, chitosan, antibacterial materials, sterilization, biodegradable sensors
MeSH terms
Animals, Biocompatible Materials, Cardiovascular Diseases, Dogs, Dyspnea, Electronics, Monitoring, Physiologic, Polyesters, Postoperative Care, Absorbable Implants, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review