High-performance, polymer-based direct cellular interfaces for electrical stimulation and recording
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Due to the trade-off between their electrical/electrochemical performance and underwater stability, realizing polymer-based, high-performance direct cellular interfaces for electrical stimulation and recording has been very challenging. Herein, we developed transparent and conductive direct cellular interfaces based on a water-stable, high-performance poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) film via solvent-assisted crystallization. The crystallized PEDOT:PSS on a polyethylene terephthalate (PET) substrate exhibited excellent electrical/electrochemical/optical characteristics, long-term underwater stability without film dissolution/delamination, and good viability for primarily cultured cardiomyocytes and neurons over several weeks. Furthermore, the highly crystallized, nanofibrillar PEDOT:PSS networks enabled dramatically enlarged surface areas and electrochemical activities, which were successfully employed to modulate cardiomyocyte beating via direct electrical stimulation. Finally, the high-performance PEDOT:PSS layer was seamlessly incorporated into transparent microelectrode arrays for efficient, real-time recording of cardiomyocyte action potentials with a high signal fidelity. All these results demonstrate the strong potential of crystallized PEDOT:PSS as a crucial component for a variety of versatile bioelectronic interfaces. Cardiomyocyte cells can be cultured and made to pulse on demand using transparent polymers with good stability. Conductive thin films formed from poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) have low impedances, making them ideal for bioelectronic interfaces. But they suffer from severe fragility in aqueous environments. Myung-Han Yoon from Korea’s Gwangju Institute of Science and Technology and colleagues have made PEDOT:PSS films that show no degradation up to three weeks underwater. They achieved this by immersing the films in concentrated sulfuric acid to initiate solvent-assisted crystallization. The crystalline films had improved electrical/electrochemical properties and biocompatibility over approaches such as polymer cross-linking, and supported photolithographic patterning into microelectrode arrays. Using cardiac cells as a model, the researchers demonstrated the feasibility of modulating beating frequencies with direct electrical stimulation under 1V while simultaneously capturing real-time action potentials and calcium signals. The high performance polymer-based conductive cellular interface was developed by a solvent-assisted crystallization of PEDOT:PSS. The crystallized PEDOT:PSS(c-PEDOT:PSS) exhibited mechanical and electrical robustness over 21days as well as excellent electrical conductivity and electrochemical activities. Thanks to such advantageous properties for the cellular interfaces, the beating rates of cardiomyocytes cultured on c-PEDOT:PSS were successfully modulated through pulsed direct stimulation under 1 V. In addition, c-PEDOT:PSS incorporated Multielectrode arrays (MEAs) recorded real-time action potentials originated from cardiomyocytes with high signal fidelity. we expect c-PEDOT:PSS with high-performance and high-stability to be a promising candidate for long-term bioelectronic interface development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404
Cited by
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Cell-based biosensors: Recent trends, challenges and future perspectives
Gupta, N., Renugopalakrishnan, V., Liepmann, D., Paulmurugan, R., & Malhotra, B. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111435 · Cited by 318
Kang, D.-H., Louis, F., Liu, H., Shimoda, H., Nishiyama, Y., Nozawa, H., Kakitani, M., Takagi, D., Kasa, D., Nagamori, E., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25236-9 · Cited by 307
Self-citationGulino, M., Kim, D., Pané, S., Santos, S. D., & Pêgo, A. P. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00689 · Cited by 159
System for recording from multiple flexible polyimide neural probes in freely behaving animals
van Daal, R. J. J., Sun, J.-J., Ceyssens, F., Michon, F., Kraft, M., Puers, R., & Kloosterman, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5e19 · Cited by 18
Metadata
- Authors
- Kim, S.-M., Kim, N., Kim, Y., Baik, M.-S., Yoo, M., Kim, D., Lee, W.-J., Kang, D.-H., Kim, S., Lee, K., & Yoon, M.-H.
- Venue
- NPG Asia Materials
- Published
- 2018-04
- Volume
- 10
- Issue
- 4
- Pages
- 255-265
- ISSN
- 1884-4049 (ISSN-L)
- 1884-4057
- OpenAlex
- W2798188227
- Cited by
- 87
- References
- 4
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-performance, polymer-based direct cellular interfaces for electrical stimulation and recording. https://app.cochat.ai/papers/10.1038/s41427-018-0014-9
- The paper
- Kim, S.-M., Kim, N., Kim, Y., Baik, M.-S., Yoo, M., Kim, D., Lee, W.-J., Kang, D.-H., Kim, S., Lee, K., & Yoon, M.-H. (2018). High-performance, polymer-based direct cellular interfaces for electrical stimulation and recording. NPG Asia Materials. https://doi.org/10.1038/s41427-018-0014-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.