Remote light-controlled intracellular target recognition by photochromic fluorescent glycoprobes
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Development of powerful fluorescence imaging probes and techniques sets the basis for the spatiotemporal tracking of cells at different physiological and pathological stages. While current imaging approaches rely on passive probe–analyte interactions, here we develop photochromic fluorescent glycoprobes capable of remote light-controlled intracellular target recognition. Conjugation between a fluorophore and spiropyran produces the photochromic probe, which is subsequently equipped with a glycoligand “antenna” to actively localize a target cell expressing a selective receptor. We demonstrate that the amphiphilic glycoprobes that form micelles in water can selectively enter the target cell to operate photochromic cycling as controlled by alternate UV/Vis irradiations. We further show that remote light conversion of the photochromic probe from one isomeric state to the other activates its reactivity toward a target intracellular analyte, producing locked fluorescence that is no longer photoisomerizable. We envision that this research may spur the use of photochromism for the development of bioimaging probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Fluorescence: Principles and Applications
Valeur, B., & Berberan‐Santos, M. N. (2012) · Wiley eBooks · doi:10.1002/9783527650002 · Cited by 4,098
Photochromism of Diarylethene Molecules and Crystals: Memories, Switches, and Actuators
Irie, M., Fukaminato, T., Matsuda, K., & Kobatake, S. (2014) · Chemical Reviews · doi:10.1021/cr500249p · Cited by 2,932
Molecular Fluorescence: Principles and Applications
Valeur, B. (2001) · Wiley eBooks · doi:10.1002/3527600248 · Cited by 1,931
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Reversible Photocontrol of Biological Systems by the Incorporation of Molecular Photoswitches
Szymański, W., Beierle, J. M., Kistemaker, H. A. V., Velema, W. A., & Feringa, B. L. (2013) · Chemical Reviews · doi:10.1021/cr300179f · Cited by 1,239
Self-citationPhotopharmacology: Beyond Proof of Principle
Velema, W. A., Szymanski, W., & Feringa, B. L. (2014) · Journal of the American Chemical Society · doi:10.1021/ja413063e · Cited by 1,178
Self-citationFRET-Based Small-Molecule Fluorescent Probes: Rational Design and Bioimaging Applications
Yuan, L., Lin, W., Zheng, K., & Zhu, S. (2013) · Accounts of Chemical Research · doi:10.1021/ar300273v · Cited by 1,021
A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins
Lukinavičius, G., Umezawa, K., Olivier, N., Honigmann, A., Yang, G., Plass, T., Mueller, V., Reymond, L., Corrêa Jr, I. R., Luo, Z.-G., et al. (2013) · Nature Chemistry · doi:10.1038/nchem.1546 · Cited by 893
Cited by
Fluorogenic probes for disease-relevant enzymes
Zhang, J., Chai, X., He, X.-P., Kim, H.-J., Yoon, J., & Tian, H. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00907k · Cited by 606
Self-citationQi, J., Chen, C., Zhang, X., Hu, X., Ji, S., Kwok, R. T. K., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2018) · Nature Communications · doi:10.1038/s41467-018-04222-8 · Cited by 350
Zhang, W., Huo, F., Cheng, F., & Yin, C. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c00992 · Cited by 267
Fluorescent probes for the detection of disease-associated biomarkers
Dou, W.-T., Han, H.-H., Sedgwick, A. C., Zhu, G.-B., Zang, Y., Yang, X.-R., Yoon, J., James, T. D., Li, J., & He, X.-P. (2022) · Science Bulletin · doi:10.1016/j.scib.2022.01.014 · Cited by 266
Self-citationThe Endeavor of Diarylethenes: New Structures, High Performance, and Bright Future
Zhang, J., & Tian, H. (2018) · Advanced Optical Materials · doi:10.1002/adom.201701278 · Cited by 246
Self-citationReaction-based fluorescent probes for SO2 derivatives and their biological applications
Li, K., Li, L.-L., Zhou, Q., Yu, K.-K., Kim, J. S., & Yu, X.-Q. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2019.03.001 · Cited by 225
Zhang, W., Huo, F., Yue, Y., Zhang, Y., Chao, J., Cheng, F., & Yin, C. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.9b13936 · Cited by 224
Chai, X., Han, H.-H., Sedgwick, A. C., Li, N., Zang, Y., James, T. D., Zhang, J., Hu, X.-L., Yu, Y., Li, Y., et al. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c05379 · Cited by 205
Self-citationResponsive small-molecule luminescence probes for sulfite/bisulfite detection in food samples
Feng, H., Liu, J., Qaitoon, A., Meng, Q., Sultanbawa, Y., Zhang, Z., Xu, Z. P., & Zhang, R. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116199 · Cited by 173
Huang, Y., Zhang, Y., Huo, F., Chao, J., Cheng, F., & Yin, C. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c10210 · Cited by 164
Wu, Y., Huang, S., Wang, J., Sun, L., Zeng, F., & Wu, S. (2018) · Nature Communications · doi:10.1038/s41467-018-06499-1 · Cited by 162
“It was calculated according to the equations (1) or (2):”
Method
Metadata
- Authors
- Zhang, J., Fu, Y., Han, H.-H., Zang, Y., Li, J., He, X.-P., Feringa, B. L., & Tian, H.
- Venue
- Nature Communications
- Published
- 2017-10-17
- Volume
- 8
- Issue
- 1
- Pages
- 987-987
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2763918550
- Cited by
- 185
- References
- 45
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.