The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Motion model ultrasound localization microscopy for preclinical and clinical multiparametric tumor characterization
Open accessAbstract
Super-resolution imaging methods promote tissue characterization beyond the spatial resolution limits of the devices and bridge the gap between histopathological analysis and non-invasive imaging. Here, we introduce motion model ultrasound localization microscopy (mULM) as an easily applicable and robust new tool to morphologically and functionally characterize fine vascular networks in tumors at super-resolution. In tumor-bearing mice and for the first time in patients, we demonstrate that within less than 1 min scan time mULM can be realized using conventional preclinical and clinical ultrasound devices. In this context, next to highly detailed images of tumor microvascularization and the reliable quantification of relative blood volume and perfusion, mULM provides multiple new functional and morphological parameters that discriminate tumors with different vascular phenotypes. Furthermore, our initial patient data indicate that mULM can be applied in a clinical ultrasound setting opening avenues for the multiparametric characterization of tumors and the assessment of therapy response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular mechanisms and clinical applications of angiogenesis
Carmeliet, P., & Jain, R. K. (2011) · Nature · doi:10.1038/nature10144 · Cited by 5,467
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Imaging biomarker roadmap for cancer studies
O'Connor, J. P. B., Aboagye, E. O., Adams, J. E., Aerts, H. J. W. L., Barrington, S. F., Beer, A. J., Boellaard, R., Bohndiek, S. E., Brady, M., Brown, G., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.162 · Cited by 1,091
The Role of Mechanical Forces in Tumor Growth and Therapy
Jain, R. K., Martin, J. D., & Stylianopoulos, T. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105259 · Cited by 1,044
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Claudon, M., Dietrich, C. F., Choi, B. I., Cosgrove, D. O., Kudo, M., Nolsøe, C. P., Piscaglia, F., Wilson, S. R., Barr, R. G., Chammas, M. C., et al. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.002 · Cited by 971
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Specialization of tumour vasculature
Ruoslahti, E. (2002) · Nature Reviews Cancer · doi:10.1038/nrc724 · Cited by 722
Preparing for Precision Medicine
Mirnezami, R., Nicholson, J., & Darzi, A. (2012) · New England Journal of Medicine · doi:10.1056/nejmp1114866 · Cited by 663
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Self-citationUltrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Deep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Lammers, T. (2024) · Advanced Materials · doi:10.1002/adma.202312169 · Cited by 290
Self-citationde Maar, J. S., Sofias, A. M., Porta Siegel, T., Vreeken, R. J., Moonen, C., Bos, C., & Deckers, R. (2020) · Theranostics · doi:10.7150/thno.38625 · Cited by 71
Metadata
- Authors
- Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., & Kiessling, F.
- Venue
- Nature Communications
- Published
- 2018-04-18
- Volume
- 9
- Issue
- 1
- Pages
- 1527-1527
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2800873425
- Cited by
- 295
- References
- 38
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Motion model ultrasound localization microscopy for preclinical and clinical multiparametric tumor characterization. https://app.cochat.ai/papers/10.1038/s41467-018-03973-8
- The paper
- Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., & Kiessling, F. (2018). Motion model ultrasound localization microscopy for preclinical and clinical multiparametric tumor characterization. Nature Communications. https://doi.org/10.1038/s41467-018-03973-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.