Motion model ultrasound localization microscopy for preclinical and clinical multiparametric tumor characterization
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Super-resolution imaging methods promote tissue characterization beyond the spatial resolution limits of the devices and bridge the gap between histopathological analysis and non-invasive imaging. Here, we introduce motion model ultrasound localization microscopy (mULM) as an easily applicable and robust new tool to morphologically and functionally characterize fine vascular networks in tumors at super-resolution. In tumor-bearing mice and for the first time in patients, we demonstrate that within less than 1 min scan time mULM can be realized using conventional preclinical and clinical ultrasound devices. In this context, next to highly detailed images of tumor microvascularization and the reliable quantification of relative blood volume and perfusion, mULM provides multiple new functional and morphological parameters that discriminate tumors with different vascular phenotypes. Furthermore, our initial patient data indicate that mULM can be applied in a clinical ultrasound setting opening avenues for the multiparametric characterization of tumors and the assessment of therapy response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular mechanisms and clinical applications of angiogenesis
Carmeliet, P., & Jain, R. K. (2011) · Nature · doi:10.1038/nature10144 · Cited by 5,467
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Imaging biomarker roadmap for cancer studies
O'Connor, J. P. B., Aboagye, E. O., Adams, J. E., Aerts, H. J. W. L., Barrington, S. F., Beer, A. J., Boellaard, R., Bohndiek, S. E., Brady, M., Brown, G., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.162 · Cited by 1,091
The Role of Mechanical Forces in Tumor Growth and Therapy
Jain, R. K., Martin, J. D., & Stylianopoulos, T. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105259 · Cited by 1,044
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Claudon, M., Dietrich, C. F., Choi, B. I., Cosgrove, D. O., Kudo, M., Nolsøe, C. P., Piscaglia, F., Wilson, S. R., Barr, R. G., Chammas, M. C., et al. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.002 · Cited by 971
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Specialization of tumour vasculature
Ruoslahti, E. (2002) · Nature Reviews Cancer · doi:10.1038/nrc724 · Cited by 722
Preparing for Precision Medicine
Mirnezami, R., Nicholson, J., & Darzi, A. (2012) · New England Journal of Medicine · doi:10.1056/nejmp1114866 · Cited by 663
Biomarkers of response and resistance to antiangiogenic therapy
Jain, R. K., Duda, D. G., Willett, C. G., Sahani, D. V., Zhu, A. X., Loeffler, J. S., Batchelor, T. T., & Sorensen, A. G. (2009) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2009.63 · Cited by 572
Combining two strategies to improve perfusion and drug delivery in solid tumors
Stylianopoulos, T., & Jain, R. K. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1318415110 · Cited by 508
In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles
Christensen-Jeffries, K. M., Browning, R. J., Tang, M., Dunsby, C. W., & Eckersley, R. J. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2359650 · Cited by 489
Mechanical induction of the tumorigenic β-catenin pathway by tumour growth pressure
Fernández-Sánchez, M. E., Barbier, S., Whitehead, J., Béalle, G., Michel, A., Latorre-Ossa, H., Rey, C., Fouassier, L., Claperon, A., Brullé, L., et al. (2015) · Nature · doi:10.1038/nature14329 · Cited by 371
Acoustic super-resolution with ultrasound and microbubbles
Viessmann, O. M., Eckersley, R. J., Christensen-Jeffries, K., Tang, M. X., & Dunsby, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/18/6447 · Cited by 277
Lin, F., Shelton, S. E., Espíndola, D., Rojas, J. D., Pinton, G., & Dayton, P. A. (2017) · Theranostics · doi:10.7150/thno.16899 · Cited by 260
Tolaney, S. M., Boucher, Y., Duda, D. G., Martin, J. D., Seano, G., Ancukiewicz, M., Barry, W. T., Goel, S., Lahdenrata, J., Isakoff, S. J., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1518808112 · Cited by 258
Simultaneous measurement of RBC velocity, flux, hematocrit and shear rate in vascular networks
Kamoun, W. S., Chae, S.-S., Lacorre, D. A., Tyrrell, J. A., Mitre, M., Gillissen, M. A., Fukumura, D., Jain, R. K., & Munn, L. L. (2010) · Nature Methods · doi:10.1038/nmeth.1475 · Cited by 214
Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images
Ackermann, D., & Schmitz, G. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2015.2500266 · Cited by 172
Self-citationUltrasound localization microscopy to image and assess microvasculature in a rat kidney
Foiret, J., Zhang, H., Ilovitsh, T., Mahakian, L., Tam, S., & Ferrara, K. W. (2017) · Scientific Reports · doi:10.1038/s41598-017-13676-7 · Cited by 169
Boonstra, H., Oosterhuis, J. W., Oosterhuis, A. M., & Fleuren, G. J. (1983) · Virchows Archiv A Pathological Anatomy and Histopathology · doi:10.1007/bf00695061 · Cited by 165
Microvascular corrosion casting in the study of tumor vascularity: a review.
Konerding, M. A., Miodoński, A. J., & Lametschwandtner, A. (1995) · PubMed · Cited by 164
Birner, P., Piribauer, M., Fischer, I., Gatterbauer, B., Marosi, C., Ambros, P. F., Ambros, I. M., Bredel, M., Oberhuber, G., Rössler, K., et al. (2003) · Brain Pathology · doi:10.1111/j.1750-3639.2003.tb00013.x · Cited by 158
Micro-CT Imaging of Tumor Angiogenesis
Ehling, J., Theek, B., Gremse, F., Baetke, S., Möckel, D., Maynard, J., Ricketts, S.-A., Grüll, H., Neeman, M., Knuechel, R., et al. (2014) · The American Journal of Pathology · doi:10.1016/j.ajpath.2013.10.014 · Cited by 150
Self-citationLassau, N., Bonastre, J., Kind, M., Vilgrain, V., Lacroix, J., Cuinet, M., Taieb, S., Aziza, R., Sarran, A., Labbé-Devilliers, C., et al. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000085 · Cited by 150
Subwavelength motion-correction for ultrafast ultrasound localization microscopy
Hingot, V., Errico, C., Tanter, M., & Couture, O. (2017) · Ultrasonics · doi:10.1016/j.ultras.2017.01.008 · Cited by 135
Tumor Vascularity in the Prognostic Assessment of Primary Cutaneous Melanoma
Kashani–Sabet, M., Sagebiel, R. W., Ferreira, C. M. M., Nosrati, M., & Miller, J. R. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.07.082 · Cited by 134
Imalytics Preclinical: Interactive Analysis of Biomedical Volume Data
Gremse, F., Stärk, M., Ehling, J., Menzel, J. R., Lammers, T., & Kiessling, F. (2016) · Theranostics · doi:10.7150/thno.13624 · Cited by 134
Self-citationImaging tumor vascularity by tracing single microbubbles
Siepmann, M., Schmitz, G., Bzyl, J., Palmowski, M., & Kiessling, F. M. (2011) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2011.0476 · Cited by 101
Self-citationDimastromatteo, J., Brentnall, T. A., & Kelly, K. A. (2016) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2016.144 · Cited by 96
Angiogenesis imaging in the management of prostate cancer
Padhani, A. R., Harvey, C. J., & Cosgrove, D. O. (2005) · Nature Clinical Practice Urology · doi:10.1038/ncpuro0356 · Cited by 66
Pysz, M. A., Foygel, K., Panje, C. M., Needles, A., Tian, L., & Willmann, J. K. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181f9202d · Cited by 61
Dynamic Contrast-Enhanced Ultrasound Parametric Maps to Evaluate Intratumoral Vascularization
Pitre-Champagnat, S., Leguerney, I., Bosq, J., PERONNEAU, P., Kiessling, F. M., Calmels, L., Coulot, J., & Lassau, N. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000101 · Cited by 57
Self-citationFokong, S., Siepmann, M., Liu, Z., Schmitz, G., Kiessling, F. M., & Gätjens, J. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.07.001 · Cited by 55
Self-citationChow, K. L., Gobin, Y. P., Cloughesy, T. F., Sayre, J. W., Villablanca, J. P., & Viñuela, F. (2000) · PubMed Central · Cited by 47
Wang, H., Lutz, A. M., Hristov, D. H., Tian, L., & Willmann, J. K. (2016) · Radiology · doi:10.1148/radiol.2016160032 · Cited by 32
Vascular patterns provide therapeutic targets in aggressive neuroblastic tumors
Tadeo, I., Bueno, G., Berbegall, A. P., Fernández-Carrobles, M. M., Castel, V., García‐Rojo, M., Navarro, S., & Noguera, R. (2016) · Oncotarget · doi:10.18632/oncotarget.7661 · Cited by 27
Technology Insight: advances in liver imaging
Hamer, O. W., Schlottmann, K., Sirlin, C. B., & Feuerbach, S. (2007) · Nature Clinical Practice Gastroenterology & Hepatology · doi:10.1038/ncpgasthep0766 · Cited by 21
Cited by
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Self-citationUltrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Deep learning in ultrasound imaging
van Sloun, R. J. G., Cohen, R., & Eldar, Y. C. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2932116 · Cited by 316
Lammers, T. (2024) · Advanced Materials · doi:10.1002/adma.202312169 · Cited by 290
Self-citationDeep Unfolded Robust PCA With Application to Clutter Suppression in Ultrasound
Solomon, O., Cohen, R., Zhang, Y., Yang, Y., He, Q., Luo, J., van Sloun, R. J. G., & Eldar, Y. C. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2941271 · Cited by 215
“One important imaging modality is contrast-enhanced ultrasound (CEUS) [2] which allows the detection and visualization of blood vessels whose physical parameters such as relative blood volume (rBV), velocity, shape and density are associated with different clinical conditions [3].”
Background
Metadata
- Authors
- Opacic, T., Dencks, S., Theek, B., Piepenbrock, M., Ackermann, D., Rix, A., Lammers, T., Stickeler, E., Delorme, S., Schmitz, G., & Kiessling, F.
- Venue
- Nature Communications
- Published
- 2018-04-18
- Volume
- 9
- Issue
- 1
- Pages
- 1527-1527
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2800873425
- Cited by
- 295
- References
- 38
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.