Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 172

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images

Ackermann, Dimitri, Schmitz, Georg · 2016 · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

Abstract

The imaging of microvessels and the quantification of their blood flow is of particular interest in the characterization of tumor vasculature. The imaging resolution (50-200 μm) of high-frequency ultrasound (US) (20-50 MHz) is not sufficient to image microvessels (~10 μm) and Doppler sensitivity is not high enough to measure capillary blood flow (~1 mm/s). For imaging of blood flow in microvessels, our approach is to detect single microbubbles (MBs), track them over several frames, and to estimate their velocity. First, positions of MBs will be detected by separating B-mode frames in a moving foreground and a static background. For the crucial task of association of these positions to tracks, we implemented a modified Markov chain Monte Carlo data association (MCMCDA) algorithm, which can handle a high number of MBs. False alarms, the detection, initiation, and termination of MBs tracks are incorporated in the underlying model. To test the performance of algorithms, a US imaging simulation of a vessel tree with flowing MBs was set up (resolution 148 μm). The trajectories and flow velocity in the vessels with a lateral distance of 100 μm were reconstructed with super-resolution. In a phantom experiment, a suspension of MBs was pumped through a tube (diameter 0.4 mm) at speeds of 2.2, 4.2, 6.3, and 10.5 mm/s and was imaged with a Vevo2100 system (Visualsonics). Estimated mean speeds of the MBs were 2.1, 4.7, 7, and 10.5 mm/s. To demonstrate the applicability for in vivo measurements, a tumor xenograft-bearing mouse was imaged by this approach. The tumor vasculature was visualized with higher resolution than in a maximum intensity persistence image and the velocity values were in the expected range 0-1 mm/s.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tuffc.2015.2500266

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 172

Metadata

Authors
Ackermann, D., & Schmitz, G.
Venue
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Published
2016-01
Volume
63
Issue
1
Pages
72-82
ISSN
  • 0885-3010 (ISSN-L)
  • 1525-8955
OpenAlex
W2173940267
Cited by
172
References
5
FWCI
5.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images. https://app.cochat.ai/papers/10.1109/tuffc.2015.2500266
The paper
Ackermann, D., & Schmitz, G. (2016). Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2015.2500266

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.