Probing the gating mechanism of the mechanosensitive channel Piezo1 with the small molecule Yoda1
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Piezo proteins are transmembrane ion channels which transduce many forms of mechanical stimuli into electrochemical signals. Their pore, formed by the assembly of three identical subunits, opens by an unknown mechanism. Here, to probe this mechanism, we investigate the interaction of Piezo1 with the small molecule agonist Yoda1. By engineering chimeras between mouse Piezo1 and its Yoda1-insensitive paralog Piezo2, we first identify a minimal protein region required for Yoda1 sensitivity. We next study the effect of Yoda1 on heterotrimeric Piezo1 channels harboring wild type subunits and Yoda1-insensitive mutant subunits. Using calcium imaging and patch-clamp electrophysiology, we show that hybrid channels harboring as few as one Yoda1-sensitive subunit exhibit Yoda1 sensitivity undistinguishable from homotrimeric wild type channels. Our results show that the Piezo1 pore remains fully open if only one subunit remains activated. This study sheds light on the gating and pharmacological mechanisms of a member of the Piezo channel family.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316
Piezo1 integration of vascular architecture with physiological force
Li, J., Hou, B., Tumova, S., Muraki, K., Bruns, A., Ludlow, M. J., Sedo, A., Hyman, A. J., McKeown, L., Young, R. S., et al. (2014) · Nature · doi:10.1038/nature13701 · Cited by 1,223
Piezo proteins are pore-forming subunits of mechanically activated channels
Coste, B., Xiao, B., Santos, J. S., Syeda, R., Grandl, J., Spencer, K. S., Kim, S. E., Schmidt, M., Mathur, J., Dubin, A. E., et al. (2012) · Nature · doi:10.1038/nature10812 · Cited by 1,167
Piezo2 is the major transducer of mechanical forces for touch sensation in mice
Ranade, S. S., Woo, S.-H., Dubin, A. E., Moshourab, R. A., Wetzel, C., Petrus, M., Mathur, J., Bégay, V., Coste, B., Mainquist, J., et al. (2014) · Nature · doi:10.1038/nature13980 · Cited by 928
Determination of the subunit stoichiometry of a voltage-activated potassium channel
MacKinnon, R. (1991) · Nature · doi:10.1038/350232a0 · Cited by 927
Piezo1, a mechanically activated ion channel, is required for vascular development in mice
Ranade, S. S., Qiu, Z., Woo, S.-H., Hur, S. S., Murthy, S. E., Cahalan, S. M., Xu, J., Mathur, J., Bandell, M., Coste, B., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1409233111 · Cited by 901
Crowding induces live cell extrusion to maintain homeostatic cell numbers in epithelia
Eisenhoffer, G. T., Loftus, P. D., Yoshigi, M., Otsuna, H., Chien, C.-B., Morcos, P. A., & Rosenblatt, J. (2012) · Nature · doi:10.1038/nature10999 · Cited by 875
Mechanical stretch triggers rapid epithelial cell division through Piezo1
Gudipaty, S. A., Lindblom, J., Loftus, P. D., Redd, M. J., Edes, K., Davey, C. F., Krishnegowda, V., & Rosenblatt, J. (2017) · Nature · doi:10.1038/nature21407 · Cited by 803
Chemical activation of the mechanotransduction channel Piezo1
Syeda, R., Xu, J., Dubin, A. E., Coste, B., Mathur, J., Huynh, T., Matzen, J., Lao, J., Tully, D. C., Engels, I. H., et al. (2015) · eLife · doi:10.7554/elife.07369 · Cited by 737
Piezo2 is the principal mechanotransduction channel for proprioception
Woo, S.-H., Lukacs, V., de Nooij, J. C., Zaytseva, D., Criddle, C. R., Francisco, A., Jessell, T. M., Wilkinson, K. A., & Patapoutian, A. (2015) · Nature Neuroscience · doi:10.1038/nn.4162 · Cited by 660
Cited by
Discoveries in structure and physiology of mechanically activated ion channels
Kefauver, J. M., Ward, A. B., & Patapoutian, A. (2020) · Nature · doi:10.1038/s41586-020-2933-1 · Cited by 604
Piezos thrive under pressure: mechanically activated ion channels in health and disease
Murthy, S. E., Dubin, A. E., & Patapoutian, A. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.92 · Cited by 582
Force-induced conformational changes in PIEZO1
Lin, Y.-C., Guo, Y. R., Miyagi, A., Levring, J., MacKinnon, R., & Scheuring, S. (2019) · Nature · doi:10.1038/s41586-019-1499-2 · Cited by 433
Mechanisms of mechanotransduction and physiological roles of PIEZO channels
Xiao, B. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00773-5 · Cited by 287
A mechanism for the activation of the mechanosensitive Piezo1 channel by the small molecule Yoda1
Botello-Smith, W. M., Jiang, W., Zhang, H., Ozkan, A. D., Lin, Y.-C., Pham, C. N., Lacroix, J. J., & Luo, Y. (2019) · Nature Communications · doi:10.1038/s41467-019-12501-1 · Cited by 274
Self-citationMechanically activated ion channel PIEZO1 is required for lymphatic valve formation
Nonomura, K., Lukacs, V., Sweet, D. T., Goddard, L. M., Kanie, A., Whitwam, T., Ranade, S. S., Fujimori, T., Kahn, M. L., & Patapoutian, A. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1817070115 · Cited by 267
Force Sensing by Piezo Channels in Cardiovascular Health and Disease
Beech, D. J., & Kalli, A. C. (2019) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.119.313348 · Cited by 242
The Urothelium: Life in a Liquid Environment
Dalghi, M. G., Montalbetti, N., Carattino, M. D., & Apodaca, G. (2020) · Physiological Reviews · doi:10.1152/physrev.00041.2019 · Cited by 201
Piezo Ion Channels in Cardiovascular Mechanobiology
Douguet, D., Patel, A., Xu, A., Vanhoutte, P. M., & Honoré, E. (2019) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2019.10.002 · Cited by 199
Cardiac Mechano-Electric Coupling: Acute Effects of Mechanical Stimulation on Heart Rate and Rhythm
Quinn, T. A., & Kohl, P. (2021) · Physiological Reviews · doi:10.1152/physrev.00036.2019 · Cited by 191
Structural Designs and Mechanogating Mechanisms of the Mechanosensitive Piezo Channels
Jiang, Y., Yang, X., Jiang, J., & Xiao, B. (2021) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2021.01.008 · Cited by 186
Blythe, N. M., Muraki, K., Ludlow, M. J., Stylianidis, V., Gilbert, H. T. J., Evans, E. L., Cuthbertson, K., Foster, R., Swift, J., Li, J., et al. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.ra119.009167 · Cited by 181
Choi, D., Park, E., Jung, E., Cha, B., Lee, S., Yu, J., Kim, P. M., Lee, S., Hong, Y. J., Koh, C. J., et al. (2019) · JCI Insight · doi:10.1172/jci.insight.125068 · Cited by 176
Levering Mechanically Activated Piezo Channels for Potential Pharmacological Intervention
Xiao, B. (2020) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010919-023703 · Cited by 163
Caolo, V., Debant, M., Endesh, N., Futers, T. S., Lichtenstein, L., Bartoli, F., Parsonage, G., Jones, E. A., & Beech, D. J. (2020) · eLife · doi:10.7554/elife.50684 · Cited by 93
Structural and thermodynamic framework for PIEZO1 modulation by small molecules
Jiang, W., Wijerathne, T. D., Zhang, H., Lin, Y.-C., Jo, S., Im, W., Lacroix, J. J., & Luo, Y. L. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2310933120 · Cited by 44
Self-citationVerkest, C., Roettger, L., Zeitzschel, N., & Lechner, S. G. (2025) · Nature Communications · doi:10.1038/s41467-025-67610-x · Cited by 12
(2025) · doi:10.1101/2025.07.10.664100 · Cited by 12
Hu, X., Shinn, P., Itkin, Z., Ye, L., Zhang, Y.-Q., Shen, M., Ford-Scheimer, S., & Hall, M. D. (2024) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.4c00256 · Cited by 3
(2024) · doi:10.1101/2024.04.21.590471 · Cited by 3
Metadata
- Authors
- Lacroix, J. J., Botello-Smith, W. M., & Luo, Y.
- Venue
- Nature Communications
- Published
- 2018-05-23
- Volume
- 9
- Issue
- 1
- Pages
- 2029-2029
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2803410170
- Cited by
- 166
- References
- 50
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.