Smartphone app for non-invasive detection of anemia using only patient-sourced photos
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
We introduce a paradigm of completely non-invasive, on-demand diagnostics that may replace common blood-based laboratory tests using only a smartphone app and photos. We initially targeted anemia, a blood condition characterized by low blood hemoglobin levels that afflicts >2 billion people. Our app estimates hemoglobin levels by analyzing color and metadata of fingernail bed smartphone photos and detects anemia (hemoglobin levels <12.5 g dL−1) with an accuracy of ±2.4 g dL−1 and a sensitivity of 97% (95% CI, 89–100%) when compared with CBC hemoglobin levels (n = 100 subjects), indicating its viability to serve as a non-invasive anemia screening tool. Moreover, with personalized calibration, this system achieves an accuracy of ±0.92 g dL−1 of CBC hemoglobin levels (n = 16), empowering chronic anemia patients to serially monitor their hemoglobin levels instantaneously and remotely. Our on-demand system enables anyone with a smartphone to download an app and immediately detect anemia anywhere and anytime.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
Dermatologist-level classification of skin cancer with deep neural networks
Esteva, A., Kuprel, B., Novoa, R. A., Ko, J., Swetter, S. M., Blau, H. M., & Thrun, S. (2017) · Nature · doi:10.1038/nature21056 · Cited by 14,362
Robust Locally Weighted Regression and Smoothing Scatterplots
Cleveland, W. S. (1979) · Journal of the American Statistical Association · doi:10.1080/01621459.1979.10481038 · Cited by 11,594
Management of Hyperbilirubinemia in the Newborn Infant 35 or More Weeks of Gestation
Hyperbilirubinemia, S. O. (2004) · Pediatrics · doi:10.1542/peds.114.1.297 · Cited by 2,850
Galanello, R., & Origa, R. (2010) · Orphanet Journal of Rare Diseases · doi:10.1186/1750-1172-5-11 · Cited by 1,466
Melanocyte biology and skin pigmentation
Lin, J. Y., & Fisher, D. E. (2007) · Nature · doi:10.1038/nature05660 · Cited by 1,379
Dorsey, E. R., & Topol, E. J. (2016) · New England Journal of Medicine · doi:10.1056/nejmra1601705 · Cited by 1,211
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Self-citationI. Using the Bland–Altman method to measure agreement with repeated measures
Myles, P. S., & Cui, J. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem214 · Cited by 620
Children's fear during procedural pain: Preliminary investigation of the Children's Fear Scale.
McMurtry, C. M., Noel, M., Chambers, C. T., & McGrath, P. J. (2011) · Health Psychology · doi:10.1037/a0024817 · Cited by 416
Guidelines for the clinical use of red cell transfusions
(2001) · British Journal of Haematology · doi:10.1046/j.1365-2141.2001.02701.x · Cited by 402
Diagnostic Inaccuracy of Smartphone Applications for Melanoma Detection
Wolf, J. A., Moreau, J. F., Akilov, O., Patton, T., English, J. C., Ho, J., & Ferris, L. K. (2013) · JAMA Dermatology · doi:10.1001/jamadermatol.2013.2382 · Cited by 393
Evaluation of "HemoCue," a new device for determining hemoglobin.
von Schenck, H., Falkensson, M., & Lundberg, B. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.3.526 · Cited by 258
Bland, J. M., & Altman, D. G. (1986) · The Lancet · doi:10.1016/s0140-6736(86)91008-1 · Cited by 191
Neufeld, L., García-Guerra, A., Sánchez-Francia, D., Newton-Sánchez, O., Ramírez-Villalobos, M. D., & Rivera-Dommarco, J. (2002) · Salud Pública de México · doi:10.1590/s0036-36342002000300005 · Cited by 175
Lamhaut, L., Apriotesei, R., Combes, X., Lejay, M., Carli, P., & Vivien, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182270c22 · Cited by 160
Measurement of skin color: practical application and theoretical considerations.
Takiwaki, H. (1998) · PubMed · Cited by 159
The Relation of Conjunctival Pallor to the Presence of Anemia
Sheth, T. N., BartsSc, Choudhry, N. K., Bowes, M., & Detsky, A. S. (1997) · Journal of General Internal Medicine · doi:10.1007/s11606-006-5004-x · Cited by 151
Non-Invasive Detection of Anaemia Using Digital Photographs of the Conjunctiva
Collings, S., Thompson, O. B., Hirst, E. R., Goossens, L., George, A., & Weinkove, R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0153286 · Cited by 131
HemaApp: noninvasive blood screening of hemoglobin using smartphone cameras
Wang, E. J., Li, W. H. C., Hawkins, D. S., Gernsheimer, T., Norby-Slycord, C. J., & Patel, S. (2016) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/2971648.2971653 · Cited by 118
Accuracy and Reliability of Pallor for Detecting Anaemia: A Hospital-Based Diagnostic Accuracy Study
Kalantri, A., Karambelkar, M., Joshi, R. P., Kalantri, S., & Jajoo, U. N. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008545 · Cited by 111
Karnad, A. B. (1985) · Archives of Internal Medicine · doi:10.1001/archinte.145.7.1270 · Cited by 97
Marn, H., & Critchley, J. (2016) · The Lancet Global Health · doi:10.1016/s2214-109x(16)00005-x · Cited by 82
The Automated Complete Blood Cell Count
Karnad, A. B. (1985) · Archives of Internal Medicine · doi:10.1001/archinte.1985.00360070150025 · Cited by 79
Radtke, H., Polat, G., Kalus, U. J., Salama, A., & Kiesewetter, H. (2005) · Transfusion and Apheresis Science · doi:10.1016/j.transci.2004.11.004 · Cited by 70
Murphy, M. F., Knechtli, C., Downie, C., Rogers, S., & Lucas, G. (2001) · British Journal of Haematology · doi:10.1046/j.1365-2141.2001.02821-2.x · Cited by 68
Skelton, V. A., Wijayasinghe, N., Sharafudeen, S., Sange, A., Parry, N., & Junghans, C. (2012) · Anaesthesia · doi:10.1111/anae.12039 · Cited by 67
Disposable platform provides visual and color-based point-of-care anemia self-testing
Tyburski, E. A., Gillespie, S. E., Stoy, W. A., Mannino, R. G., Weiss, A. J., Siu, A. F., Bulloch, R. H., Thota, K., Cardenas, A., Session, W., et al. (2014) · Journal of Clinical Investigation · doi:10.1172/jci76666 · Cited by 64
Self-citationNovel Telemedicine Device for Diagnosis of Corneal Abrasions and Ulcers in Resource-Poor Settings
Maamari, R. N., Ausayakhun, S., Margolis, T. P., Fletcher, D. A., & Keenan, J. D. (2014) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.335 · Cited by 56
Evaluation of the Haemoglobin Colour Scale and comparison with the HemoCue haemoglobin assay.
Paddle, J. (2002) · Europe PMC (PubMed Central) · Cited by 48
Assessment of a Smartphone Otoscope Device for the Diagnosis and Management of Otitis Media
Rappaport, K., McCracken, C. C., Beniflah, J. D., Little, W. K., Fletcher, D. A., Lam, W. A., & Shane, A. L. (2016) · Clinical Pediatrics · doi:10.1177/0009922815593909 · Cited by 44
Self-citationChina's Mobile Economy: Opportunities in the Largest and Fastest Information Consumption Boom
Ma, W. (2016) · Wiley eBooks · doi:10.1002/9781119321392 · Cited by 40
Jaggernath, M., Naicker, R., Madurai, S., Brockman, M. A., Ndung’u, T., & Gelderblom, H. C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0152184 · Cited by 39
Cited by
Precision medicine, AI, and the future of personalized health care
Johnson, K. B., Wei, W., Weeraratne, D., Frisse, M. E., Misulis, K., Rhee, K., Zhao, J., & Snowdon, J. L. (2021) · Clinical and Translational Science · doi:10.1111/cts.12884 · Cited by 1,854
“91 The widespread use of home monitoring and wearable devices has long been accompanied by the expectation that collected data could help detect disease at an earlier state.”
BackgroundMountjoy, M., Ackerman, K. E., Bailey, D. M., Burke, L. M., Constantini, N., Hackney, A. C., Heikura, I. A., Melin, A., Pensgaard, A. M., Stellingwerff, T., et al. (2023) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-106994 · Cited by 974
Artificial intelligence in clinical medicine: catalyzing a sustainable global healthcare paradigm
Krishnan, G., Singh, S., Pathania, M., Gosavi, S., Abhishek, S., Parchani, A., & Dhar, M. (2023) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2023.1227091 · Cited by 296
Detection of anaemia from retinal fundus images via deep learning
Mitani, A., Huang, A., Venugopalan, S., Corrado, G. S., Peng, L., Webster, D. R., Hammel, N., Liu, Y., & Varadarajan, A. V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0487-z · Cited by 230
Ackerman, K. E., Rogers, M. A., Heikura, I. A., Burke, L. M., Stellingwerff, T., Hackney, A. C., Verhagen, E., Schley, S., Saville, G. H., Mountjoy, M., et al. (2023) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-107359 · Cited by 43
Metadata
- Authors
- Mannino, R. G., Myers, D. R., Tyburski, E. A., Caruso, C., Boudreaux, J., Leong, T., Clifford, G. D., & Lam, W. A.
- Venue
- Nature Communications
- Published
- 2018-12-04
- Volume
- 9
- Issue
- 1
- Pages
- 4924-4924
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2901330522
- Cited by
- 272
- References
- 34
- FWCI
- 35.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.