The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Single particle cryo-EM reconstruction of 52 kDa streptavidin at 3.2 Angstrom resolution
Open accessAbstract
The fast development of single-particle cryogenic electron microscopy (cryo-EM) has made it more feasible to obtain the 3D structure of well-behaved macromolecules with a molecular weight higher than 300 kDa at ~3 Å resolution. However, it remains a challenge to obtain the high-resolution structures of molecules smaller than 200 kDa using single-particle cryo-EM. In this work, we apply the Cs-corrector-VPP-coupled cryo-EM to study the 52 kDa streptavidin (SA) protein supported on a thin layer of graphene and embedded in vitreous ice. We are able to solve both the apo-SA and biotin-bound SA structures at near-atomic resolution using single-particle cryo-EM. We demonstrate that the method has the potential to determine the structures of molecules as small as 39 kDa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446
Rosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Cited by
Challenges and opportunities in cryo-EM single-particle analysis
Lyumkis, D. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev118.005602 · Cited by 356
The promise and the challenges of cryo‐electron tomography
Turk, M., & Baumeister, W. (2020) · FEBS Letters · doi:10.1002/1873-3468.13948 · Cited by 333
Protein Design: From the Aspect of Water Solubility and Stability
Qing, R., Hao, S., Smorodina, E., Jin, D., Zalevsky, A., & Zhang, S. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00757 · Cited by 312
Cryo-EM: the resolution revolution and drug discovery
de Oliveira, T. M., van Beek, L., Shilliday, F., Debreczeni, J. É., & Phillips, C. (2021) · SLAS DISCOVERY · doi:10.1177/2472555220960401 · Cited by 73
Castells-Graells, R., Meador, K., Arbing, M. A., Sawaya, M. R., Gee, M., Cascio, D., Gleave, E., Debreczeni, J. É., Breed, J., Leopold, K., et al. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2305494120 · Cited by 48
Metadata
- Authors
- Fan, X., Wang, J., Zhang, X., Yang, Z., Zhang, J.-C., Zhao, L., Peng, H.-L., Lei, J., & Wang, H.-W.
- Venue
- Nature Communications
- Published
- 2019-06-03
- Volume
- 10
- Issue
- 1
- Pages
- 2386-2386
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2901198387
- Cited by
- 163
- References
- 2
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single particle cryo-EM reconstruction of 52 kDa streptavidin at 3.2 Angstrom resolution. https://app.cochat.ai/papers/10.1038/s41467-019-10368-w
- The paper
- Fan, X., Wang, J., Zhang, X., Yang, Z., Zhang, J.-C., Zhao, L., Peng, H.-L., Lei, J., & Wang, H.-W. (2019). Single particle cryo-EM reconstruction of 52 kDa streptavidin at 3.2 Angstrom resolution. Nature Communications. https://doi.org/10.1038/s41467-019-10368-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.