The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Measurement of the variation of electron-to-proton mass ratio using ultracold molecules produced from laser-cooled atoms
Open accessAbstract
Experimental techniques to manipulate cold molecules have seen great development in recent years. The precision measurements of cold molecules are expected to give insights into fundamental physics. Here we use a rovibrationally pure sample of ultracold KRb molecules to improve the measurement on the stability of electron-to-proton mass ratio $$\left( {\mu = \frac{{m_{\mathrm{e}}}}{{M_{\mathrm{p}}}}} \right)$$ μ = m e M p . The measurement is based upon a large sensitivity coefficient of the molecular spectroscopy, which utilizes a transition between a nearly degenerate pair of vibrational levels each associated with a different electronic potential. Observed limit on temporal variation of μ is $$\frac{1}{\mu }\frac{{d\mu }}{{dt}} = (0.30 \pm 1.0) \times 10^{ - 14} \, {\mathrm{year}}^{ - 1}$$ 1 μ d μ d t = ( 0.30 ± 1.0 ) × 1 0 - 14 year - 1 , which is better by a factor of five compared with the most stringent laboratory molecular limits to date. Further improvements should be straightforward, because our measurement was only limited by statistical errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“To date, the best constraint has been obtained from KRb (Kobayashi et al. 2019).”
From Fundamental constants: from measurement to the universe, a window on gravitation and cosmology (2025) · cites this paper as Kobayashi et al. 2019
In the citing paper
“Using a transition between nearly a degenerate pair of vibrational levels each associated with a different electronic potential of ultracold diatomic alkali KRb molecules that enjoys a large sensitivity coefficient, Dm=m ' ð14 890 Æ 60ÞD l= l, it was concluded that _ l l ¼ ð0:3 Æ 1:0Þ Â 10 À14 yr À1 :ð154Þ”
From Fundamental constants: from measurement to the universe, a window on gravitation and cosmology (2025) · cites this paper as Kobayashi et al. 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cold and ultracold molecules: science, technology and applications
Carr, L. D., DeMille, D., Krems, R. V., & Ye, J. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/5/055049 · Cited by 1,330 · cited 2×
“[4] Carr L.”
The fundamental constants and their variation: observational and theoretical status
Uzan, J.-P. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.403 · Cited by 1,162 · cited 1×
“[6, 7].”
Improved limit on the electric dipole moment of the electron
ACME Collaboration (2018) · Nature · doi:10.1038/s41586-018-0599-8 · Cited by 965
Improved measurement of the shape of the electron
Hudson, J. J., Kara, D. M., Smallman, I. J., Sauer, B. E., Tarbutt, M. R., & Hinds, E. A. (2011) · Nature · doi:10.1038/nature10104 · Cited by 746
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Precision Measurement of the Electron’s Electric Dipole Moment Using Trapped Molecular Ions
Cairncross, W. B., Gresh, D. N., Grau, M., Cossel, K. C., Roussy, T. S., Ni, Y., Zhou, Y., Ye, J., & Cornell, E. A. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.153001 · Cited by 375 · cited 1×
“341 MHz, respectively [2]) and result from the dependence of the coupling constants on the internuclear distance.”
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366 · cited 2×
“[10] Huntemann, N.”
Precision Test of Mass-Ratio Variations with Lattice-Confined Ultracold Molecules
Zelevinsky, T., Kotochigova, S., & Ye, J. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.043201 · Cited by 266 · cited 1×
“Another solution to achieve a narrower linewidth is holding the molecules in an optical lattice with a magic wavelength[19].”
Coherent Transfer of Photoassociated Molecules into the Rovibrational Ground State
Aikawa, K., Akamatsu, D., Hayashi, M., Oasa, K., Kobayashi, J., Naidon, P., Kishimoto, T., Ueda, M., & Inouye, S. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.203001 · Cited by 232 · cited 3×
“Our experimental procedure for producing KRb molecules is described in detail in [12](Fig.”
InfluentialSelf-citationStability of the Proton-to-Electron Mass Ratio
Shelkovnikov, A., Butcher, R. J., Chardonnet, C., & Amy-Klein, A. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.150801 · Cited by 219 · cited 1×
“We obtain a better result than previous measurements using molecules [8].”
Research works printed but not linked: 1
- Townes, C. H. & Schawlow, A. L. Microwave Spectroscopy. (Dover Publications, New York, 1975).
Cited by
Quantum sensing and metrology for fundamental physics with molecules
DeMille, D. P., Hutzler, N. R., Rey, A. M., & Zelevinsky, T. (2024) · Nature Physics · doi:10.1038/s41567-024-02499-9 · Cited by 203
“The best laboratory molecular limits on η variations are obtained using a clock transition in ultracold, untrapped KRb molecules 47 , though at a level ~300 times less sensitive than from atomic clocks.”
Polyatomic molecules as quantum sensors for fundamental physics
Hutzler, N. R. (2020) · Quantum Science and Technology · doi:10.1088/2058-9565/abb9c5 · Cited by 114
“This approach was recently implemented in ultracold KRb on a transition between excited vibrational states in singlet X1Σ and triplet a3Σ electronic ground states with a sensitivity of Kμ ≈ 15, 000 to set a limit of |μ̇/μ| 10−14/yr [170] over a ∼1 year timescale.”
Fitch, N. J., & Tarbutt, M. R. (2021) · Advances in atomic, molecular, and optical physics · doi:10.1016/bs.aamop.2021.04.003 · Cited by 128
Long term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
“Additionally, certain molecular transitions can be highly sensitive to variations of μ due to a cancellation between electronic and rovibrational energies [6–8].”
Enhanced sensitivity to ultralight bosonic dark matter in the spectra of the linear radical SrOH
Kozyryev, I., Lasner, Z., & Doyle, J. M. (2021) · Physical Review A · doi:10.1103/physreva.103.043313 · Cited by 69
Metadata
- Authors
- Kobayashi, J., Ogino, A., & Inouye, S.
- Affiliations
- Kyoto University (JP)
- The University of Tokyo (JP)
- Osaka City University (JP)
- Corresponding author
- Kobayashi, J.
- ORCID
- Kobayashi, J.
- Venue
- Nature Communications
- Published
- 2019-08-21
- Volume
- 10
- Issue
- 1
- Pages
- 3771-3771
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC6704166
- OpenAlex
- W2969216380
- Semantic Scholar
- f1856a2dd1c8c4cdfa78b71b4e772dc99f1047f5
- Cited by
- 55
- References
- 20
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 9 · 2023: 10 · 2022: 6 · 2021: 9 · 2020: 8 · 2019: 2
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- arXiv (Cornell University)
- Funders
- Japan Society for the Promotion of Science (23684034, 24104702)
- Precursory Research for Embryonic Science and Technology
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- proton-electron mass ratio, variation of fundamental constants, ultracold molecules, KRb molecules, laser cooling, molecular spectroscopy, electronic potential
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of the variation of electron-to-proton mass ratio using ultracold molecules produced from laser-cooled atoms. https://app.cochat.ai/papers/10.1038/s41467-019-11761-1
- The paper
- Kobayashi, J., Ogino, A., & Inouye, S. (2019). Measurement of the variation of electron-to-proton mass ratio using ultracold molecules produced from laser-cooled atoms. Nature Communications. https://doi.org/10.1038/s41467-019-11761-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.