Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Measurement of the variation of electron-to-proton mass ratio using ultracold molecules produced from laser-cooled atoms

Open access
Kobayashi, J., Ogino, A., Inouye, S. · 2019 · Nature Communications

Abstract

Experimental techniques to manipulate cold molecules have seen great development in recent years. The precision measurements of cold molecules are expected to give insights into fundamental physics. Here we use a rovibrationally pure sample of ultracold KRb molecules to improve the measurement on the stability of electron-to-proton mass ratio $$\left( {\mu = \frac{{m_{\mathrm{e}}}}{{M_{\mathrm{p}}}}} \right)$$ μ = m e M p . The measurement is based upon a large sensitivity coefficient of the molecular spectroscopy, which utilizes a transition between a nearly degenerate pair of vibrational levels each associated with a different electronic potential. Observed limit on temporal variation of μ is $$\frac{1}{\mu }\frac{{d\mu }}{{dt}} = (0.30 \pm 1.0) \times 10^{ - 14} \, {\mathrm{year}}^{ - 1}$$ 1 μ d μ d t = ( 0.30 ± 1.0 ) × 1 0 - 14 year - 1 , which is better by a factor of five compared with the most stringent laboratory molecular limits to date. Further improvements should be straightforward, because our measurement was only limited by statistical errors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-019-11761-1

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Closely lying states of a 41K87Rb molecule15. In the shallow range of the potentials, several pairs of closely lying vibrational states in X1Σ+ and a3Σ+ potentials are found. Among such pairs, we selected the combination of v = 86 state in X1Σ+ and v = 16 state in a3Σ+. The large difference of potential depth between X1Σ+ and a3Σ+ leads to the large sensitivity W ≡ ∂ν/∂(ln μ) ≈ −9.5 THz, whereas the transition frequency itself (≡ν) is in the microwave range (≈635 MHz). This yields a large sensitivity coefficient |Kμ| ≡ |W/ν| ≈ 15,000
Fig. 1 Closely lying states of a 41K87Rb molecule15. In the shallow range of the potentials, several pairs of closely lying vibrational states in X1Σ+ and a3Σ+ potentials are found. Among such pairs, we selected the combination of v = 86 state in X1Σ+ and v = 16 state in a3Σ+. The large difference of potential depth between X1Σ+ and a3Σ+ leads to the large sensitivity W ≡ ∂ν/∂(ln μ) ≈ −9.5 THz, whereas the transition frequency itself (≡ν) is in the microwave range (≈635 MHz). This yields a large sensitivity coefficient |Kμ| ≡ |W/ν| ≈ 15,000CC BY · PubMed Central
Fig. 2 Production and detection of ultracold molecules. First, ultracold atoms in a dual-species magneto-optical trap (MOT) were photoassociated into a weakly bound state. The molecules were transferred to the target internal state by stimulated Raman adiabatic passage (STIRAP) and irradiated with a microwave pulse. State selective detection of the molecules was achieved by ionizing the molecules with a pulsed laser and detecting them with a microchannel plate (MCP)
Fig. 2 Production and detection of ultracold molecules. First, ultracold atoms in a dual-species magneto-optical trap (MOT) were photoassociated into a weakly bound state. The molecules were transferred to the target internal state by stimulated Raman adiabatic passage (STIRAP) and irradiated with a microwave pulse. State selective detection of the molecules was achieved by ionizing the molecules with a pulsed laser and detecting them with a microchannel plate (MCP)CC BY · PubMed Central
Fig. 3 Typical spectrum of the |i〉 − |f〉 transition. Average of the ion signals and its standard deviations of mean (shown in black) are plotted against the microwave frequency. The total number of original data points used to make this plot is ~95,000, which corresponds to 6 h of data collection. To find the central frequency, the spectrum is fitted to a Gaussian function (magenta curve). Subtracting the Gaussian function from the ion counts gives the clear view of the residuals. The full-width-of-half-maximum (FWHM) of the spectrum is about 50 Hz, which is limited by the microwave pulse duration of 16 ms
Fig. 3 Typical spectrum of the |i〉 − |f〉 transition. Average of the ion signals and its standard deviations of mean (shown in black) are plotted against the microwave frequency. The total number of original data points used to make this plot is ~95,000, which corresponds to 6 h of data collection. To find the central frequency, the spectrum is fitted to a Gaussian function (magenta curve). Subtracting the Gaussian function from the ion counts gives the clear view of the residuals. The full-width-of-half-maximum (FWHM) of the spectrum is about 50 Hz, which is limited by the microwave pulse duration of 16 msCC BY · PubMed Central
Fig. 4 Measurement of the temporal variation of μ. The resonance frequencies of the |i〉 − |f〉 transition are plotted for compensated Zeeman shifts. The error bars denote statistical standard deviations of mean. The magenta line shows a linear fit to the data with statistical errors. We obtained the temporal variation of the transition frequency f: 1/fdf/dt=(-0.44±1.47stat±0.24syst)×10⁻¹⁰year⁻¹
Fig. 4 Measurement of the temporal variation of μ. The resonance frequencies of the |i〉 − |f〉 transition are plotted for compensated Zeeman shifts. The error bars denote statistical standard deviations of mean. The magenta line shows a linear fit to the data with statistical errors. We obtained the temporal variation of the transition frequency f: 1/fdf/dt=(-0.44±1.47stat±0.24syst)×10⁻¹⁰year⁻¹CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Research works printed but not linked: 1

  1. Townes, C. H. & Schawlow, A. L. Microwave Spectroscopy. (Dover Publications, New York, 1975).

Cited by

See all 55

Metadata

Authors
Kobayashi, J., Ogino, A., & Inouye, S.
Affiliations
  • Kyoto University (JP)
  • The University of Tokyo (JP)
  • Osaka City University (JP)
Corresponding author
Kobayashi, J.
Venue
Nature Communications
Published
2019-08-21
Volume
10
Issue
1
Pages
3771-3771
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2969216380
Cited by
55
References
20
Citations by year
2026: 2 · 2025: 9 · 2024: 9 · 2023: 10 · 2022: 6 · 2021: 9 · 2020: 8 · 2019: 2
FWCI
2.75
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University)
Funders
  • Japan Society for the Promotion of Science (23684034, 24104702)
  • Precursory Research for Embryonic Science and Technology
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
Keywords
proton-electron mass ratio, variation of fundamental constants, ultracold molecules, KRb molecules, laser cooling, molecular spectroscopy, electronic potential

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of the variation of electron-to-proton mass ratio using ultracold molecules produced from laser-cooled atoms. https://app.cochat.ai/papers/10.1038/s41467-019-11761-1
The paper
Kobayashi, J., Ogino, A., & Inouye, S. (2019). Measurement of the variation of electron-to-proton mass ratio using ultracold molecules produced from laser-cooled atoms. Nature Communications. https://doi.org/10.1038/s41467-019-11761-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.