Highly selective detection of methanol over ethanol by a handheld gas sensor
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Methanol poisoning causes blindness, organ failure or even death when recognized too late. Currently, there is no methanol detector for quick diagnosis by breath analysis or for screening of laced beverages. Typically, chemical sensors cannot distinguish methanol from the much higher ethanol background. Here, we present an inexpensive and handheld sensor for highly selective methanol detection. It consists of a separation column (Tenax) separating methanol from interferants like ethanol, acetone or hydrogen, as in gas chromatography, and a chemoresistive gas sensor (Pd-doped SnO 2 nanoparticles) to quantify the methanol concentration. This way, methanol is measured within 2 min from 1 to 1000 ppm without interference of much higher ethanol levels (up to 62,000 ppm). As a proof-of-concept, we reliably measure methanol concentrations in spiked breath samples and liquor. This could enable the realization of highly selective sensors in emerging applications such as breath analysis or air quality monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Low-temperature hydrogen production from water and methanol using Pt/α-MoC catalysts
Lin, L., Zhou, W., Gao, R., Yao, S., Zhang, X., Xu, W., Zheng, S., Jiang, Z., Yu, Q., Li, Y.-W., et al. (2017) · Nature · doi:10.1038/nature21672 · Cited by 1,564
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Miniaturized gas ionization sensors using carbon nanotubes
Modi, A., Koratkar, N., Lass, E., Wei, B., & Ajayan, P. M. (2003) · Nature · doi:10.1038/nature01777 · Cited by 986
Three-dimensional integration of nanotechnologies for computing and data storage on a single chip
Shulaker, M. M., Hills, G., Park, R. S., Howe, R. T., Saraswat, K., Wong, H.-S. P., & Mitra, S. (2017) · Nature · doi:10.1038/nature22994 · Cited by 866
American Academy of Clinical Toxicology Practice Guidelines on the Treatment of Methanol Poisoning
The American Academy of Clinical To, Barceloux, D. G., Randall Bond, G., Krenzelok, E. P., Cooper, H., & Allister Vale, J. (2002) · Journal of Toxicology: Clinical Toxicology · doi:10.1081/clt-120006745 · Cited by 838
McNair, H. M., Miller, J. M., & Snow, N. H. (2019) · Wiley eBooks · doi:10.1002/9781119450795 · Cited by 586
An optoelectronic nose for the detection of toxic gases
Lim, S. H., Feng, L., Kemling, J. W., Musto, C. J., & Suslick, K. S. (2009) · Nature Chemistry · doi:10.1038/nchem.360 · Cited by 476
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Self-citationACUTE METHYL ALCOHOL POISONING: A REVIEW BASED ON EXPERIENCES IN AN OUTBREAK OF 323 CASES
BENNETT, I. L., CARY, F. H., MITCHELL, G. L., & COOPER, M. N. (1953) · Medicine · doi:10.1097/00005792-195312000-00002 · Cited by 306
A systematic approach to standard addition methods in instrumental analysis
Bader, M. (1980) · Journal of Chemical Education · doi:10.1021/ed057p703 · Cited by 293
Kim, J.-H., Heller, D. A., Jin, H., Barone, P. W., Song, C., Zhang, J., Trudel, L. J., Wogan, G. N., Tannenbaum, S. R., & Strano, M. S. (2009) · Nature Chemistry · doi:10.1038/nchem.332 · Cited by 265
Güntner, A. T., Koren, V., Chikkadi, K., Righettoni, M., & Pratsinis, S. E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00008 · Cited by 257
Self-citationMethanol outbreak in Norway 2002–2004: epidemiology, clinical features and prognostic signs
HOVDA, K. E., HUNDERI, O. H., TAFJORD, A. ‐., DUNLOP, O., RUDBERG, N., & JACOBSEN, D. (2005) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2005.01521.x · Cited by 250
SIFT studies of the reactions of H3O+, NO+ and O2+ with a series of alcohols
Spanel, P., & Smith, D. (1997) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00085-2 · Cited by 231
Stretchable patterned graphene gas sensor driven by integrated micro-supercapacitor array
Yun, J., Lim, Y., Jang, G. N., Kim, D., Lee, S.-J., Park, H., Hong, S. Y., Lee, G., Zi, G., & Ha, J. S. (2016) · Nano Energy · doi:10.1016/j.nanoen.2015.11.023 · Cited by 207
Han, D., Song, P., Zhang, S., Zhang, H., Xu, Q., & Wang, Q. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.083 · Cited by 192
Defining a tolerable concentration of methanol in alcoholic drinks
Paine, A. J., & Dayan, A. D. (2001) · Human & Experimental Toxicology · doi:10.1191/096032701718620864 · Cited by 188
Kruse, J. A. (1992) · Intensive Care Medicine · doi:10.1007/bf01694340 · Cited by 169
Turner, C., Španěl, P., & Smith, D. C. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/7/007 · Cited by 150
Selective sensing of isoprene by Ti-doped ZnO for breath diagnostics
Güntner, A. T., Pineau, N. J., Chie, D., Krumeich, F., & Pratsinis, S. E. (2016) · Journal of Materials Chemistry B · doi:10.1039/c6tb01335j · Cited by 147
Self-citationNoninvasive Body Fat Burn Monitoring from Exhaled Acetone with Si-doped WO3-sensing Nanoparticles
Güntner, A. T., Sievi, N. A., Theodore, S. J., Gulich, T., Kohler, M., & Pratsinis, S. E. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02843 · Cited by 138
Self-citationZeolite membranes for highly selective formaldehyde sensors
Güntner, A. T., Abegg, S., Wegner, K., & Pratsinis, S. E. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.11.035 · Cited by 136
Self-citationHighly Selective and Rapid Breath Isoprene Sensing Enabled by Activated Alumina Filter
van den Broek, J., Güntner, A. T., & Pratsinis, S. E. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00976 · Cited by 133
Self-citationPlasmonic Sensing and Control of Single-Nanoparticle Electrochemistry
Hoener, B. S., Kirchner, S. R., Heiderscheit, T. S., Collins, S. S. E., Chang, W., Link, S., & Landes, C. F. (2018) · Chem · doi:10.1016/j.chempr.2018.04.009 · Cited by 132
The suitability of Tedlar bags for breath sampling in medical diagnostic research
Steeghs, M. M. L., Cristescu, S. M., & Harren, F. J. M. (2006) · Physiological Measurement · doi:10.1088/0967-3334/28/1/007 · Cited by 126
Sniffing Entrapped Humans with Sensor Arrays
Güntner, A. T., Pineau, N. J., Mochalski, P., Wiesenhofer, H., Agapiou, A., Mayhew, C. A., & Pratsinis, S. E. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00237 · Cited by 121
Self-citationGębicki, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.005 · Cited by 119
Alkhouri, N., Cikach, F. S., Eng, K., Moses, J., Patel, N., Chen, Y., Hanouneh, I. A., Grove, D., López, R., & Dweik, R. A. (2013) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0b013e3283650669 · Cited by 102
Guiding Ketogenic Diet with Breath Acetone Sensors
Güntner, A. T., Kompalla, J. F., Landis, H., Theodore, S. J., Geidl, B., Sievi, N. A., Kohler, M., Pratsinis, S. E., & Gerber, P. A. (2018) · Sensors · doi:10.3390/s18113655 · Cited by 97
Self-citationApproach to the Treatment of Methanol Intoxication
Kraut, J. A. (2016) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2016.02.058 · Cited by 77
Diagnosis of toxic alcohols: limitations of present methods
Kraut, J. A. (2015) · Clinical Toxicology · doi:10.3109/15563650.2015.1056880 · Cited by 54
India’s problem with toxic alcohol
D’Silva, J. (2015) · BMJ · doi:10.1136/bmj.h4536 · Cited by 10
Cited by
Advances in Noble Metal-Decorated Metal Oxide Nanomaterials for Chemiresistive Gas Sensors: Overview
Zhu, L.-Y., Ou, L.-X., Mao, L.-W., Wu, X.-Y., Liu, Y.-P., & Lu, H.-L. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01047-z · Cited by 553
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Self-citationDai, J., Ogbeide, O., Macadam, N., Sun, Q., Yu, W., Li, Y., Su, B.-L., Hasan, T., Huang, X., & Huang, W. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00459a · Cited by 378
Nanomaterial-based gas sensors used for breath diagnosis
Zhou, X., Xue, Z., Chen, X., Huang, C., Bai, W., Lu, Z., & Wang, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02518a · Cited by 227
Metadata
- Authors
- van den Broek, J., Abegg, S., Pratsinis, S. E., & Güntner, A. T.
- Venue
- Nature Communications
- Published
- 2019-09-16
- Volume
- 10
- Issue
- 1
- Pages
- 4220-4220
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2973754009
- Cited by
- 378
- References
- 33
- FWCI
- 14.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.