The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Raman image-activated cell sorting
Open accessAbstract
The advent of image-activated cell sorting and imaging-based cell picking has advanced our knowledge and exploitation of biological systems in the last decade. Unfortunately, they generally rely on fluorescent labeling for cellular phenotyping, an indirect measure of the molecular landscape in the cell, which has critical limitations. Here we demonstrate Raman image-activated cell sorting by directly probing chemically specific intracellular molecular vibrations via ultrafast multicolor stimulated Raman scattering (SRS) microscopy for cellular phenotyping. Specifically, the technology enables real-time SRS-image-based sorting of single live cells with a throughput of up to ~100 events per second without the need for fluorescent labeling. To show the broad utility of the technology, we show its applicability to diverse cell types and sizes. The technology is highly versatile and holds promise for numerous applications that are previously difficult or undesirable with fluorescence-based technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hematopoietic Stem-Cell Transplantation
Copelan, E. A. (2006) · New England Journal of Medicine · doi:10.1056/nejmra052638 · Cited by 2,522
Direct photosynthetic recycling of carbon dioxide to isobutyraldehyde
Atsumi, S., Higashide, W., & Liao, J. C. (2009) · Nature Biotechnology · doi:10.1038/nbt.1586 · Cited by 870
In Silico Labeling: Predicting Fluorescent Labels in Unlabeled Images
Christiansen, E. M., Yang, S. J., Ando, D. M., Javaherian, A., Skibinski, G., Lipnick, S., Mount, E., O’Neil, A., Shah, K., Lee, A. K., et al. (2018) · Cell · doi:10.1016/j.cell.2018.03.040 · Cited by 635
Super-multiplex vibrational imaging
Wei, L., Chen, Z., Shi, L., Long, R., Anzalone, A. V., Zhang, L., Hu, F., Yuste, R., Cornish, V. W., & Min, W. (2017) · Nature · doi:10.1038/nature22051 · Cited by 514
Cited by
Dual-frequency impedance assays for intracellular components in microalgal cells
Tang, T., Liu, X., Yuan, Y., Kiya, R., Shen, Y., Zhang, T., Suzuki, K., Tanaka, Y., Li, M., Hosokawa, Y., et al. (2022) · Lab on a Chip · doi:10.1039/d1lc00721a · Cited by 26
Self-citationLi, X., Chen, J., Yang, Y., Cai, H., Ao, Z., Xing, Y., Li, K., Yang, K., Guan, W., Friend, J., et al. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-00916-4 · Cited by 17
Recent Developments (After 2020) in Flow Cytometry Worldwide and Within China
Du, X., Chen, X., Gao, C., Wang, J., Huo, X., & Chen, J. (2025) · Biosensors · doi:10.3390/bios15030156 · Cited by 10
Metadata
- Authors
- Nitta, N., Iino, T., Isozaki, A., Yamagishi, M., Kitahama, Y., Sakuma, S., Suzuki, Y., Tezuka, H., Oikawa, M., Arai, F., Asai, T., Deng, D., Fukuzawa, H., Hase, M., Hasunuma, T., Hayakawa, T., Hiraki, K., Hiramatsu, K., Hoshino, Y., Inaba, M., Inoue, Y., Ito, T., Kajikawa, M., Karakawa, H., Kasai, Y., Kato, Y., Kobayashi, H., Lei, C., Matsusaka, S., Mikami, H., Nakagawa, A., Numata, K., Ota, T., Sekiya, T., Shiba, K., Shirasaki, Y., Suzuki, N., Tanaka, S., Ueno, S., Watarai, H., Yamano, T., Yazawa, M., Yonamine, Y., Di Carlo, D., Hosokawa, Y., Uemura, S., Sugimura, T., Ozeki, Y., & Goda, K.
- Venue
- Nature Communications
- Published
- 2020-07-10
- Volume
- 11
- Issue
- 1
- Pages
- 3452-3452
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3041069161
- Cited by
- 205
- References
- 4
- FWCI
- 12.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman image-activated cell sorting. https://app.cochat.ai/papers/10.1038/s41467-020-17285-3
- The paper
- Nitta, N., Iino, T., Isozaki, A., Yamagishi, M., Kitahama, Y., Sakuma, S., Suzuki, Y., Tezuka, H., Oikawa, M., Arai, F., Asai, T., Deng, D., Fukuzawa, H., Hase, M., Hasunuma, T., Hayakawa, T., Hiraki, K., Hiramatsu, K., Hoshino, Y., . . . Goda, K. (2020). Raman image-activated cell sorting. Nature Communications. https://doi.org/10.1038/s41467-020-17285-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.