CoChat

Converting microwave and telecom photons with a silicon photonic nanomechanical interface

Open access
Arnold, G., Wulf, M., Barzanjeh, S., Redchenko, E. S., Rueda, A., Hease, W. J., Hassani, F., Fink, J. M. · 2020 · Nature Communications

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

Practical quantum networks require low-loss and noise-resilient optical interconnects as well as non-Gaussian resources for entanglement distillation and distributed quantum computation. The latter could be provided by superconducting circuits but existing solutions to interface the microwave and optical domains lack either scalability or efficiency, and in most cases the conversion noise is not known. In this work we utilize the unique opportunities of silicon photonics, cavity optomechanics and superconducting circuits to demonstrate a fully integrated, coherent transducer interfacing the microwave X and the telecom S bands with a total (internal) bidirectional transduction efficiency of 1.2% (135%) at millikelvin temperatures. The coupling relies solely on the radiation pressure interaction mediated by the femtometer-scale motion of two silicon nanobeams reaching a V π as low as 16 μV for sub-nanowatt pump powers. Without the associated optomechanical gain, we achieve a total (internal) pure conversion efficiency of up to 0.019% (1.6%), relevant for future noise-free operation on this qubit-compatible platform.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-020-18269-z

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Silicon photonic microwave-to-optics converter. a Diagram showing the microwave (a^e), mechanical (b^), and optical (a^o) mode, and the relevant coupling and loss rates of the device. Scattering parameters Sij characterizing the transducer performance are indicated. b Schematic showing the frequencies of the coherent signals involved in the conversion process (green arrows). On the left an optical input signal (IS) is converted to an upper sideband (US) of the microwave pump signal, whereas in the microwave-to-optics conversion on the right also the lower sideband (LS) is created. The bidirectional transduction ζ is only evaluated between the upper sidebands at ωd,j + ωm. c Scanning electron micrograph of the device showing the microwave lumped element resonator with an inductively coupled feed line, the photonic crystal cavity, and the optical coupling waveguide fabricated on a fully suspended 220 nm thick silicon-on-insulator device layer. White scale bar, 10 μm. The inset shows an enlarged view of the central part (green boxed area) comprising the mechanically compliant vacuum gap capacitors of size ~70 nm and two optomechancial zipper cavities (top one unused) with a central tapered photonic crystal mirror coupled optical waveguide. White scale bar, 1 μm. d Finite-element method (FEM) simulation of the mechanical displacement ∣u∣ of the utilized mechanical resonance. e FEM simulation of the electric in-plane-field Ey(x, y) for the relevant optical mode. f Simplified experimental setup. The device is mounted on the mixing chamber plate of a cryogen-free dilution refrigerator at a temperature of Tfridge = 50 mK. A microwave switch selects between the incoming microwave and optical signal to be analyzed by the ESA. Optical heterodyning is used to detect the low power levels used in the experiment. SG microwave signal generator; ESA electronic spectrum analyzer; VOA variable optical attenuator; SSB EOM single-sideband electro-optic modulator; AOM acousto-optic modulator.
Fig. 1 Silicon photonic microwave-to-optics converter. a Diagram showing the microwave (a^e), mechanical (b^), and optical (a^o) mode, and the relevant coupling and loss rates of the device. Scattering parameters Sij characterizing the transducer performance are indicated. b Schematic showing the frequencies of the coherent signals involved in the conversion process (green arrows). On the left an optical input signal (IS) is converted to an upper sideband (US) of the microwave pump signal, whereas in the microwave-to-optics conversion on the right also the lower sideband (LS) is created. The bidirectional transduction ζ is only evaluated between the upper sidebands at ωd,j + ωm. c Scanning electron micrograph of the device showing the microwave lumped element resonator with an inductively coupled feed line, the photonic crystal cavity, and the optical coupling waveguide fabricated on a fully suspended 220 nm thick silicon-on-insulator device layer. White scale bar, 10 μm. The inset shows an enlarged view of the central part (green boxed area) comprising the mechanically compliant vacuum gap capacitors of size ~70 nm and two optomechancial zipper cavities (top one unused) with a central tapered photonic crystal mirror coupled optical waveguide. White scale bar, 1 μm. d Finite-element method (FEM) simulation of the mechanical displacement ∣u∣ of the utilized mechanical resonance. e FEM simulation of the electric in-plane-field Ey(x, y) for the relevant optical mode. f Simplified experimental setup. The device is mounted on the mixing chamber plate of a cryogen-free dilution refrigerator at a temperature of Tfridge = 50 mK. A microwave switch selects between the incoming microwave and optical signal to be analyzed by the ESA. Optical heterodyning is used to detect the low power levels used in the experiment. SG microwave signal generator; ESA electronic spectrum analyzer; VOA variable optical attenuator; SSB EOM single-sideband electro-optic modulator; AOM acousto-optic modulator.CC BY · PubMed Central
Fig. 2 Coherent scattering parameter measurements. a The reflection ∣Sjj∣2 (j = e, o) and bidirectional transduction ζ: = ∣Seo∣∣Soe∣ parameters as a function of signal tone detuning δj = ω − (ωd,j + ωm) for fixed pump powers Pe = 601 pW and Po = 625 pW. The dots represent the experimental data while the solid lines show the theoretical prediction with γm as the only fit parameter. b Measured photon number transduction efficiency as a function of microwave and optical pump powers. c Measured transduction efficiency with respect to optical pump power for fixed Pe = 601 pW. d Measured transduction efficiency with respect to microwave pump power for fixed Po = 625 pW. In (c) and (d), the error bars are the standard deviation of three independent measurement runs and solid lines are theory with interpolated γm (from (f)) and no other free parameters. e The coupling efficiency of the microwave resonator to the waveguide ηe = κex,e/κe, extracted from broadband reflection measurements, as a function of optical (blue, Pe = 601 pW) and microwave (red, Po = 625 pW) pump tones. f Intrinsic mechanical decoherence rate γm versus optical (blue, Pe = 601 pW) and microwave (red, Po = 625 pW) pump powers extracted from (c) and (d) with Eq. (3) and γm as only fit parameter. Solid lines in (f) are linear fits to the data.
Fig. 2 Coherent scattering parameter measurements. a The reflection ∣Sjj∣2 (j = e, o) and bidirectional transduction ζ: = ∣Seo∣∣Soe∣ parameters as a function of signal tone detuning δj = ω − (ωd,j + ωm) for fixed pump powers Pe = 601 pW and Po = 625 pW. The dots represent the experimental data while the solid lines show the theoretical prediction with γm as the only fit parameter. b Measured photon number transduction efficiency as a function of microwave and optical pump powers. c Measured transduction efficiency with respect to optical pump power for fixed Pe = 601 pW. d Measured transduction efficiency with respect to microwave pump power for fixed Po = 625 pW. In (c) and (d), the error bars are the standard deviation of three independent measurement runs and solid lines are theory with interpolated γm (from (f)) and no other free parameters. e The coupling efficiency of the microwave resonator to the waveguide ηe = κex,e/κe, extracted from broadband reflection measurements, as a function of optical (blue, Pe = 601 pW) and microwave (red, Po = 625 pW) pump tones. f Intrinsic mechanical decoherence rate γm versus optical (blue, Pe = 601 pW) and microwave (red, Po = 625 pW) pump powers extracted from (c) and (d) with Eq. (3) and γm as only fit parameter. Solid lines in (f) are linear fits to the data.CC BY · PubMed Central
Fig. 3 Pure and amplified conversion. a Measured total transduction efficiency ζ: = ∣Seo∣∣Soe∣ with respect to pump detuning Δo of the nonsideband resolved optical cavity for a constant intracavity photon number nd,o = 0.185. b Pure and—in the absence of thermal noise—noiseless conversion θ (green dots) as well as the total conversion gain G (blue dots) that gives rise to amplified vacuum noise. θ is extracted from (a) by dividing the measured total transduction by the calculated gain using Supplementary Eqs. (16) and (17). While Go diverges for Δo → 0, the optomechanical damping rate drops to zero and leads to a vanishing pure conversion θ. The arrows in both panels indicate the detuning used in Figs. 2 and 4.
Fig. 3 Pure and amplified conversion. a Measured total transduction efficiency ζ: = ∣Seo∣∣Soe∣ with respect to pump detuning Δo of the nonsideband resolved optical cavity for a constant intracavity photon number nd,o = 0.185. b Pure and—in the absence of thermal noise—noiseless conversion θ (green dots) as well as the total conversion gain G (blue dots) that gives rise to amplified vacuum noise. θ is extracted from (a) by dividing the measured total transduction by the calculated gain using Supplementary Eqs. (16) and (17). While Go diverges for Δo → 0, the optomechanical damping rate drops to zero and leads to a vanishing pure conversion θ. The arrows in both panels indicate the detuning used in Figs. 2 and 4.CC BY · PubMed Central
Fig. 4 Conversion noise properties. Measured noise spectra at the device output for the optical cavity (a) and the microwave resonator (b) as a function of the signal tone detuning δj = ω − (ωd,j + ωm) at fixed pump powers Pe = 601 pW and Po = 625 pW in units of added noise quanta. a The dark blue region represents the two-quadrature noise added by the optical measurement chain; the light blue region indicates the thermal mechanical noise added to the converted optical output signal. b Bottom light red region represents the two-quadrature background noise from the microwave measurement chain. The central dark red region indicates a small amount of broadband resonator noise and the light blue region the transduction noise due to the thermal population of the mechanical mode. In both panels, fits to one common mechanical bath nm are shown in black. c Mechanical bath temperature Tm,bath extracted as only fit parameter from fits to the measured output noise as in (a) and (b) with respect to optical (blue dots, Pe = 601 pW) and microwave (red dots, Po = 625 ± 19 pW) pump power. Black lines show fits to the data with the logarithmic growth function Tm,bath=0.18loge(Po)−0.47 and Tm,bath = 0.70 K respectively. The dashed line indicates the thermalized mechanical mode temperature Tsample when both pumps are off. d Microwave (red, nadd,e) and optical (blue, nadd,o) added noise photons at the output with respect to optical pump power (Pe = 601 pW). The full theory based on an interpolation of Tm,bath from (c) is shown as black lines.
Fig. 4 Conversion noise properties. Measured noise spectra at the device output for the optical cavity (a) and the microwave resonator (b) as a function of the signal tone detuning δj = ω − (ωd,j + ωm) at fixed pump powers Pe = 601 pW and Po = 625 pW in units of added noise quanta. a The dark blue region represents the two-quadrature noise added by the optical measurement chain; the light blue region indicates the thermal mechanical noise added to the converted optical output signal. b Bottom light red region represents the two-quadrature background noise from the microwave measurement chain. The central dark red region indicates a small amount of broadband resonator noise and the light blue region the transduction noise due to the thermal population of the mechanical mode. In both panels, fits to one common mechanical bath nm are shown in black. c Mechanical bath temperature Tm,bath extracted as only fit parameter from fits to the measured output noise as in (a) and (b) with respect to optical (blue dots, Pe = 601 pW) and microwave (red dots, Po = 625 ± 19 pW) pump power. Black lines show fits to the data with the logarithmic growth function Tm,bath=0.18loge(Po)−0.47 and Tm,bath = 0.70 K respectively. The dashed line indicates the thermalized mechanical mode temperature Tsample when both pumps are off. d Microwave (red, nadd,e) and optical (blue, nadd,o) added noise photons at the output with respect to optical pump power (Pe = 601 pW). The full theory based on an interpolation of Tm,bath from (c) is shown as black lines.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Research works printed but not linked: 1

  1. Regal, C. A. & Lehnert, K. W. From cavity electromechanics to cavity optomechanics. J. Phys.: Conf. Ser. 264, 012025 (2011).

Cited by

See all 93

Metadata

Authors
Arnold, G., Wulf, M., Barzanjeh, S., Redchenko, E. S., Rueda, A., Hease, W. J., Hassani, F., & Fink, J. M.
Affiliations
Institute of Science and Technology Austria (AT)
Corresponding author
Fink, J. M.
Venue
Nature Communications
Published
2020-09-08
Volume
11
Issue
1
Pages
4460-4460
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3008542284
Cited by
83
References
36
Citations by year
2026: 5 · 2025: 13 · 2024: 14 · 2023: 13 · 2022: 21 · 2021: 13 · 2020: 4
FWCI
5.39
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University)
Funders
  • Institute of Science and Technology Austria (754411)
  • European Commission (732894, HORIZON2020, 754411, 862644, 758053)
  • Österreichischen Akademie der Wissenschaften (754411)
  • Austrian Science Fund
  • NOMIS Stiftung (758053)
  • H2020 European Research Council (758053)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Orbital Angular Momentum in Optics
Keywords
microwave-to-optical transduction, silicon photonics, cavity optomechanics, superconducting circuits, quantum networks, radiation pressure, nanobeams, transduction efficiency, quantum interface, millikelvin temperatures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Converting microwave and telecom photons with a silicon photonic nanomechanical interface. https://app.cochat.ai/papers/10.1038/s41467-020-18269-z
The paper
Arnold, G., Wulf, M., Barzanjeh, S., Redchenko, E. S., Rueda, A., Hease, W. J., Hassani, F., & Fink, J. M. (2020). Converting microwave and telecom photons with a silicon photonic nanomechanical interface. Nature Communications. https://doi.org/10.1038/s41467-020-18269-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.