The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Non-dispersive infrared multi-gas sensing via nanoantenna integrated narrowband detectors
Open accessAbstract
Non-dispersive infrared (NDIR) spectroscopy analyzes the concentration of target gases based on their characteristic infrared absorption. In conventional NDIR gas sensors, an infrared detector has to pair with a bandpass filter to select the target gas. However, multiplexed NDIR gas sensing requires multiple pairs of bandpass filters and detectors, which makes the sensor bulky and expensive. Here, we propose a multiplexed NDIR gas sensing platform consisting of a narrowband infrared detector array as read-out. By integrating plasmonic metamaterial absorbers with pyroelectric detectors at the pixel level, the detectors exhibit spectrally tunable and narrowband photoresponses, circumventing the need for separate bandpass filter arrays. We demonstrate the sensing of H 2 S, CH 4, CO 2, CO, NO, CH 2 O, NO 2, SO 2. The detection limits of common gases such as CH 4, CO 2, and CO are 63 ppm, 2 ppm, and 11 ppm, respectively. We also demonstrate the deduction of the concentrations of two target gases in a mixture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Infrared spectroscopy of proteins
Barth, A. (2007) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/j.bbabio.2007.06.004 · Cited by 5,129
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Schliesser, A., Picqué, N., & Hänsch, T. W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.142 · Cited by 1,436
Knight, M. W., King, N. S., Liu, L., Everitt, H. O., Nordlander, P., & Halas, N. J. (2014) · ACS Nano · doi:10.1021/nn405495q · Cited by 1,261
Infrared spectroscopy of biomolecules
Howland, J. L. (1996) · Biochemical Education · doi:10.1016/0307-4412(96)82531-3 · Cited by 799
Refractory Plasmonics with Titanium Nitride: Broadband Metamaterial Absorber
Li, W., Guler, U., Kinsey, N., Naik, G. V., Boltasseva, A., Guan, J., Shalaev, V. M., & Kildishev, A. V. (2014) · Advanced Materials · doi:10.1002/adma.201401874 · Cited by 772
Infrared spectroscopy of biomolecules
Mantsch, H. H., & Chapman, D. (1996) · Cited by 608
Dinh, T.-V., Choi, I.-Y., Son, Y.-S., & Kim, J.-C. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.03.040 · Cited by 482
Mapping Heat Origin in Plasmonic Structures
Baffou, G., Girard, C., & Quidant, R. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.136805 · Cited by 327
Towards Integrated Mid-Infrared Gas Sensors
Popa, D., & Udrea, F. (2019) · Sensors · doi:10.3390/s19092076 · Cited by 311
All-Glass, Large Metalens at Visible Wavelength Using Deep-Ultraviolet Projection Lithography
Park, J.-S., Zhang, S., She, A., Chen, W. T., Lin, P., Yousef, K. M. A., Cheng, J.-X., & Capasso, F. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b03333 · Cited by 307
Hodgkinson, J., Smith, R., Ho, W. O., Saffell, J. R., & Tatam, R. P. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.06.006 · Cited by 218
Vincent, T. A., & Gardner, J. W. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.04.016 · Cited by 171
Multifunctional metamaterial pyroelectric infrared detectors
Suen, J. Y., Fan, K., Montoya, J. A., Bingham, C. M., Stenger, V. E., Sriram, S., & Padilla, W. J. (2017) · Optica · doi:10.1364/optica.4.000276 · Cited by 150
Zero-power infrared digitizers based on plasmonically enhanced micromechanical photoswitches
Qian, Z., Kang, S., Rajaram, V., Cassella, C., McGruer, N. E., & Rinaldi, M. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.147 · Cited by 143
Ultra-thin infrared metamaterial detector for multicolor imaging applications
Montoya, J. A., Tian, Z., Krishna, S., & Padilla, W. J. (2017) · Optics Express · doi:10.1364/oe.25.023343 · Cited by 90
Wavelength selective wideband uncooled infrared sensor using a two-dimensional plasmonic absorber
Ogawa, S., Komoda, J., Masuda, K., & Kimata, M. (2013) · Optical Engineering · doi:10.1117/1.oe.52.12.127104 · Cited by 54
Cited by
Advances in Noble Metal-Decorated Metal Oxide Nanomaterials for Chemiresistive Gas Sensors: Overview
Zhu, L.-Y., Ou, L.-X., Mao, L.-W., Wu, X.-Y., Liu, Y.-P., & Lu, H.-L. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01047-z · Cited by 553
Wavelength-multiplexed hook nanoantennas for machine learning enabled mid-infrared spectroscopy
Ren, Z., Zhang, Z., Wei, J., Dong, B., & Lee, C. (2022) · Nature Communications · doi:10.1038/s41467-022-31520-z · Cited by 132
Cai, H., Yang, C., Liu, Y., Zhang, X., Zou, Y., & Yu, Y. (2024) · APL Photonics · doi:10.1063/5.0218976 · Cited by 10
Metadata
- Authors
- Tan, X., Zhang, H., Li, J., Wan, H., Guo, Q., Zhu, H., Liu, H., & Yi, F.
- Venue
- Nature Communications
- Published
- 2020-10-16
- Volume
- 11
- Issue
- 1
- Pages
- 5245-5245
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3092856724
- Cited by
- 311
- References
- 18
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.