Ionic shape-morphing microrobotic end-effectors for environmentally adaptive targeting, releasing, and sampling
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Shape-morphing uses a single actuation source for complex-task-oriented multiple patterns generation, showing a more promising way than reconfiguration, especially for microrobots, where multiple actuators are typically hardly available. Environmental stimuli can induce additional causes of shape transformation to compensate the insufficient space for actuators and sensors, which enriches the shape-morphing and thereby enhances the function and intelligence as well. Here, making use of the ionic sensitivity of alginate hydrogel microstructures, we present a shape-morphing strategy for microrobotic end-effectors made from them to adapt to different physiochemical environments. Pre-programmed hydrogel crosslinks were embedded in different patterns within the alginate microstructures in an electric field using different electrode configurations. These microstructures were designed for accomplishing tasks such as targeting, releasing and sampling under the control of a magnetic field and environmental ionic stimuli. In addition to structural flexibility and environmental ion sensitivity, these end-effectors are also characterized by their complete biodegradability and versatile actuation modes. The latter includes global locomotion of the whole end-effector by self-trapping magnetic microspheres as a hitch-hiker and the local opening and closing of the jaws using encapsulated nanoparticles based on local ionic density or pH values. The versatility was demonstrated experimentally in both in vitro environments and ex vivo in a gastrointestinal tract. Global locomotion was programmable and the local opening and closing was achieved by changing the ionic density or pH values. This ‘structural intelligence’ will enable strategies for shape-morphing and functionalization, which have attracted growing interest for applications in minimally invasive medicine, soft robotics, and smart materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/5174 · Cited by 8,161
Alginate: Properties and biomedical applications
Lee, K. Y., & Mooney, D. J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.003 · Cited by 8,095
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825
Small-scale soft-bodied robot with multimodal locomotion
Hu, W., Lum, G. Z., Mastrangeli, M., & Sitti, M. (2018) · Nature · doi:10.1038/nature25443 · Cited by 2,372
Alginate derivatization: A review of chemistry, properties and applications
Pawar, S. N., & Edgar, K. J. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.007 · Cited by 1,627
Pandey, R., Vats, G., Yun, J., Bowen, C. R., Ho‐Baillie, A. W. Y., Seidel, J., Butler, K. T., & Seok, S. I. (2019) · Advanced Materials · doi:10.1002/adma.201807376 · Cited by 1,069
Multifunctional Biohybrid Magnetite Microrobots for Imaging-Guided Therapy
Yan, X., Zhou, Q., Vincent, M., Deng, Y., Yu, J., Xu, J., Xu, T., Tang, T., Bian, L., Wang, Y.-X. J., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aaq1155 · Cited by 893
Designing Responsive Buckled Surfaces by Halftone Gel Lithography
Kim, J., Hanna, J. A., Byun, M., Santangelo, C. D., & Hayward, R. C. (2012) · Science · doi:10.1126/science.1215309 · Cited by 883
Bio-inspired magnetic swimming microrobots for biomedical applications
Peyer, K. E., Zhang, L., & Nelson, B. J. (2013) · Nanoscale · doi:10.1039/c2nr32554c · Cited by 820
Lanaspa, M. A., Ishimoto, T., Li, N., Cicerchi, C., Orlicky, D. J., Ruzycki, P., Rivard, C., Inaba, S., Roncal-Jimenez, C. A., Bales, E. S., et al. (2013) · Nature Communications · doi:10.1038/ncomms3929 · Cited by 796
Cited by
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
Dong, Y., Wang, L., Xia, N., Yang, Z., Zhang, C., Pan, C., Jin, D., Zhang, J., Majidi, C., & Zhang, L. (2022) · Science Advances · doi:10.1126/sciadv.abn8932 · Cited by 348
Untethered soft actuators for soft standalone robotics
Jung, Y., Kwon, K., Lee, J., & Ko, S. H. (2024) · Nature Communications · doi:10.1038/s41467-024-47639-0 · Cited by 176
“Addressing the need for environmental adaptability 152,153 , a group of engineers achieved a signi fi cant breakthrough with the design of an untethered and self-powered, electrically-driven soft robot fi t for deep-sea exploration as illustrated in Fig.”
BackgroundSkin-inspired, sensory robots for electronic implants
Zhang, L., Xing, S., Yin, H., Weisbecker, H., Tran, H. T., Guo, Z., Han, T., Wang, Y., Liu, Y., Wu, Y., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48903-z · Cited by 175
Metadata
- Authors
- Zheng, Z., Wang, H., Dong, L., Shi, Q., Li, J., Sun, T., Huang, Q., & Fukuda, T.
- Venue
- Nature Communications
- Published
- 2021-01-18
- Volume
- 12
- Issue
- 1
- Pages
- 411-411
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3123020061
- Cited by
- 189
- References
- 47
- FWCI
- 13.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.