‘MINFLUX nanometer-scale 3D imaging and microsecond-range tracking on a common fluorescence microscope’
Open accessThe DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Abstract
The recently introduced minimal photon fluxes (MINFLUX) concept pushed the resolution of fluorescence microscopy to molecular dimensions. Initial demonstrations relied on custom made, specialized microscopes, raising the question of the method’s general availability. Here, we show that MINFLUX implemented with a standard microscope stand can attain 1–3 nm resolution in three dimensions, rendering fluorescence microscopy with molecule-scale resolution widely applicable. Advances, such as synchronized electro-optical and galvanometric beam steering and a stabilization that locks the sample position to sub-nanometer precision with respect to the stand, ensure nanometer-precise and accurate real-time localization of individually activated fluorophores. In our MINFLUX imaging of cell- and neurobiological samples, ~800 detected photons suffice to attain a localization precision of 2.2 nm, whereas ~2500 photons yield precisions <1 nm (standard deviation). We further demonstrate 3D imaging with localization precision of ~2.4 nm in the focal plane and ~1.9 nm along the optic axis. Localizing with a precision of <20 nm within ~100 µs, we establish this spatio-temporal resolution in single fluorophore tracking and apply it to the diffusion of single labeled lipids in lipid-bilayer model membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, advanced MINFLUX microscopy from the Hell lab enables the tracking of particles as small as 1–2 nm for 100 s of microseconds (Eilers et al., 2018; Schmidt et al., 2021).”
From Molecular dynamics simulation of an entire cell (2023) · cites this paper as Schmidt et al., 2021
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Self-citationUltra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Self-citationFluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Self-citationThe ParaView Guide: A Parallel Visualization Application
Ayachit, U. (2015) · Cited by 1,805
Direct observation of the nanoscale dynamics of membrane lipids in a living cell
Eggeling, C., Ringemann, C., Medda, R., Schwarzmann, G., Sandhoff, K., Polyakova, S., Belov, V. N., Hein, B., von Middendorff, C., Schönle, A., et al. (2009) · Nature · doi:10.1038/nature07596 · Cited by 1,520
Self-citationNanometer resolution imaging and tracking of fluorescent molecules with minimal photon fluxes
Balzarotti, F., Eilers, Y., Gwosch, K. C., Gynnå, A. H., Westphal, V., Stefani, F. D., Elf, J., & Hell, S. W. (2017) · Science · doi:10.1126/science.aak9913 · Cited by 1,225
Self-citationWide-field subdiffraction imaging by accumulated binding of diffusing probes
Sharonov, A., & Hochstrasser, R. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609643104 · Cited by 1,151
Cited by
Items 101–200 of 309
Reply to: Assessment of 3D MINFLUX data for quantitative structural biology in cells
Gwosch, K. C., Balzarotti, F., Pape, J. K., Hoess, P., Ellenberg, J., Ries, J., Matti, U., Schmidt, R., Sahl, S. J., & Hell, S. W. (2022) · Nature Methods · doi:10.1038/s41592-022-01695-w · Cited by 11
Self-citationBredfeldt, J.-E., Oracz, J., Kiszka, K. A., Moosmayer, T., Weber, M., Sahl, S. J., & Hell, S. W. (2024) · Nature Communications · doi:10.1038/s41467-024-51160-9 · Cited by 10
“Furthermore, novel concepts have emerged — notably MINFLUX 33 – 35 and MINSTED 27 — which combine a photon-economic localization procedure through optical injection of a coordinate reference (by means of a light pattern with an intensity minimum) with the on-off switching at the level of single fl…”
BackgroundSelf-citationMINFLUX Nanoscopy: A “Brilliant” Technique Promising Major Breakthrough
Salerno, M., Bazzurro, V., Angeli, E., Bianchini, P., Roushenas, M., Pakravanan, K., & Diaspro, A. (2025) · Microscopy Research and Technique · doi:10.1002/jemt.24765 · Cited by 10
Modulated illumination localization microscopy-enabled sub-10 nm resolution
Sun, Y., Yin, L., Cai, M., Wu, H., Hao, X., Kuang, C., & Liu, X. (2022) · Journal of Innovative Optical Health Sciences · doi:10.1142/s179354582230004x · Cited by 10
“41 This de-sign builds a stabilizer based on the port of microscope stand and uses a closed-loop feedback mechanism in imaging process.”
BackgroundMethodInfluentialPrindle, J. R., de Cuba, O., & Gahlmann, A. (2023) · The Journal of Chemical Physics · doi:10.1063/5.0155638 · Cited by 12
Clowsley, A. H., Meletiou, A., Janíček, R., Bokhobza, A., Lučinskaitė, E., Bleuer, G., Jansen, I., Jones, P., Louch, W. E., & Soeller, C. (2025) · Nature Communications · doi:10.1038/s41467-025-67801-6 · Cited by 10
“…nano-positioning stage to fi x the sample position with respect to the objective lens with standard deviations typically below 1 nm over minutes and up to hours under normal laboratory conditions 47 (if mechanical agitation of the microscope by externalsourcesare kept at areasonably lowlevel).”
Self-citationDirect optical measurement of intra-molecular distances down to the Ångström scalePreprint
Sahl, S. J., Matthias, J., Inamdar, K., Khan, T. A., Weber, M., Becker, S., Griesinger, C., Broichhagen, J., & Hell, S. W. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.07.07.548133 · Cited by 10
Self-citationHegarty, C., Neto, N. G. B., Cahill, P. A., & Floudas, A. (2023) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2023.08.005 · Cited by 9
Molecular probes for super-resolution imaging of drug dynamics
Fang, H., Wang, M., Wei, P., Liu, Q., Su, Y. R., Liu, H., Chen, Y., Su, Z. G., & He, W. (2024) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2024.115330 · Cited by 10
Simple and robust 3D MINFLUX excitation with a variable phase plate
Deguchi, T., & Ries, J. (2024) · Light Science & Applications · doi:10.1038/s41377-024-01487-1 · Cited by 9
“For 3D MINFLUX, typically a top-hat phase pattern that results in a ‘ 3D donut ’ is employed and axial scanning is performed with an electro-optically actuated varifocal lens 2 or a deformable mirror 8 .”
MethodNanoscale imaging of biological systems via expansion and super-resolution microscopy
Aristova, D., Kylies, D., Rosario, M. D., Heil, H. S., Schwerk, M., Kuehl, M. B., Wong, M. N., Henriques, R., & Puelles, V. G. (2025) · Applied Physics Reviews · doi:10.1063/5.0240464 · Cited by 11
“Furthermore, recent approaches, including Minflux, 30 – 32 Minsted, 33,34 and RESI 35 have even reported sub-nanometer resolution.”
Effects of optical aberrations on localization of MINFLUX super-resolution microscopy
He, C., Zhan, Z., Li, C., Sun, X., Liu, Y., Kuang, C., & Liu, X. (2022) · Optics Express · doi:10.1364/oe.475425 · Cited by 9
Rahmani, A., Cox, T., Achary, A. T. A., & Ponjavic, A. (2024) · Optics Express · doi:10.1364/oe.520845 · Cited by 12
Large Temperature‐Jump and Nanosecond Hyperquenching for Time‐Resolved Structural Studies
Cherepanov, A. V., & Schwalbe, H. (2023) · Chemistry - Methods · doi:10.1002/cmtd.202200050 · Cited by 9
Bhattacharjee, R., & Lemke, E. A. (2024) · Journal of Molecular Biology · doi:10.1016/j.jmb.2024.168807 · Cited by 9
Reina, F., Saavedra, L. A., Eggeling, C., & Barrantes, F. J. (2025) · Nature Communications · doi:10.1038/s41467-025-61489-4 · Cited by 11
Integrated MINFLUX tracking reveals two distinct chromatin dynamics classes across cell types
Mazzocca, M., Narducci, D. N., Grosse‐Holz, S., Matthias, J., Karpova, T., & Hansen, A. S. (2026) · Nature Structural & Molecular Biology · doi:10.1038/s41594-026-01807-6 · Cited by 27
“The recorded photon numbers at each probing position, together with the known nonuniform intensity of the beam, enable precise triangulation of the particle position 50 .”
InfluentialChan, C. Y., Faragalla, Y., & Wu, L. (2022) · Biochemical Society Transactions · doi:10.1042/bst20210263 · Cited by 9
Super-Resolution Optical Imaging of Bacterial Cells
Parisi, M., Lucidi, M., Visca, P., & Cincotti, G. (2022) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2022.3228121 · Cited by 10
“have been proposed up to now, and recently the minimal photon fluxes (MINFLUX) approach has demonstrated a record 1–3 nm resolution in all three dimensions [33].”
BackgroundSystematic conformation-to-phenotype mapping via limited deep sequencing of proteins
Serebryany, E., Zhao, V. Y., Park, K., Bitran, A., Trauger, S. A., Budnik, B., & Shakhnovich, E. I. (2023) · Molecular Cell · doi:10.1016/j.molcel.2023.05.006 · Cited by 7
Yu, D.-X., Jiang, Z., Zheng, Y., Zhang, H.-R., Li, R.-Q., Zhao, Y., Lu, X., Lin, Y.-C., Liu, C., & Wang, Q. (2026) · Light Science & Applications · doi:10.1038/s41377-025-02155-8 · Cited by 7
Super-resolution microscopy and studies of peroxisomes
Galiani, S., Eggeling, C., & Reglinski, K. (2023) · Biological Chemistry · doi:10.1515/hsz-2022-0314 · Cited by 9
Tang, Z., & Zhou, P. (2024) · ChemPhysChem · doi:10.1002/cphc.202400503 · Cited by 7
3D Real-Time Two-Photon Microscopy Device for Single-Particle Holographic Tracking (3D-Red Shot)
Semmer, F., Emperauger, M.-C., Lopez, C., Bogicevic, C., Treussart, F., Perronet, K., & Marquier, F. (2023) · ACS Photonics · doi:10.1021/acsphotonics.3c00949 · Cited by 7
Cargo specificity, regulation, and therapeutic potential of cytoplasmic dynein
Park, J.-G., Jeon, H., Hwang, K. Y., Cha, S., Han, R. T., Cho, H., & Lee, I. (2024) · Experimental & Molecular Medicine · doi:10.1038/s12276-024-01200-7 · Cited by 8
“Intriguingly, an additional superresolution technique known as MINFLUX microscopy has demonstrated the ability to achieve very high localization precision of a fl uorophore, detecting as few as ~20 photons 40,41 .”
Cellular optical imaging techniques: a dynamic advancing frontier
Li, Y., Li, C., Zhou, C., Wang, J., Li, W., Pan, T., He, C., Guan, X., Wang, Y., Huang, Y., et al. (2025) · Science China Life Sciences · doi:10.1007/s11427-024-2916-5 · Cited by 6
Transition metal complexes as optical probes for super-resolution microscopy
Pramanik, S. K., Sreedharan, S., Kandoth, N., de la Serna, J. B., Das, A., & Thomas, J. A. (2025) · Nature Reviews Chemistry · doi:10.1038/s41570-025-00764-w · Cited by 11
Steves, M. A., & Xu, K. (2025) · Nature Communications · doi:10.1038/s41467-025-65529-x · Cited by 6
Liu, J., Tan, Y. Y., Zheng, W. L., Wang, Y., Ju, L. A., & Su, Q. P. (2024) · Journal of Nanobiotechnology · doi:10.1186/s12951-024-02605-2 · Cited by 8
“Furthermore, the method demands meticulous labeling optimization, especially for living cells, and produces vast data sets that necessitate sophisticated, often custom, analysis tools [35, 36, 54].”
BackgroundMethodInfluentialMINFLUX reveals nonnormal distribution of linkage errors in immunofluorescence labeling
Wang, J., Zou, H., Fu, X., Gu, C., Yao, L., Li, S., Zhang, Q., & Gu, M. (2025) · Communications Physics · doi:10.1038/s42005-025-02169-z · Cited by 6
Wei, A., Chengbing, 秦. Q., Shuai, 董. D., Xinqin, 孟. M., Yunrui, 宋. S., Xiangdong, 李. L., Xilong, 梁. L., Guofeng, 张. Z., Ruiyun, 陈. C., Jianyong, 胡. H., et al. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop230749 · Cited by 6
Sun, Y., Wu, Z., Shang, Y., Kang, S. H., & Lin, J. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117255 · Cited by 6
Luo, H., Jiang, C., Wen, Y., Wang, X., Wang, F., Liu, L., & Yu, H. (2023) · Nanoscale · doi:10.1039/d3nr04096h · Cited by 6
Breton, V., Nazac, P., Boulet, D., & Danglot, L. (2024) · Neurophotonics · doi:10.1117/1.nph.11.1.014414 · Cited by 8
“…years, since molecular probes are still up to now far beyond the recent development in instrumentation that can reach a resolution of 3 to 4 nm. 83 One interesting track will be probably the development of self-blinking dyes 84 – 86 or the development of new convertible fluorophores 28 for…”
BackgroundApplication and development of fluorescence probes in MINFLUX nanoscopy (invited paper)
Wang, J., Zhang, Z., Shen, H., Wu, Q., & Gu, M. (2022) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545822300117 · Cited by 6
Endogenous SNAP-Tagging of Munc13-1 for Monitoring Synapse Nanoarchitecture
Kowald, M., Bachollet, S. P. J. T., Benseler, F., Steinecker, M., Boll, M., Kaushik, S., Soykan, T., Sun, S., Birke, R., Ilic, D., et al. (2025) · JACS Au · doi:10.1021/jacsau.4c00946 · Cited by 6
Guo, X., Wei, L., Kundu, N., Shin, W., Chan, C. Y., Han, S., Mohseni, A., Molakarimi, M., Sun, M., Wu, X.-S., et al. (2025) · Science Advances · doi:10.1126/sciadv.ady8065 · Cited by 7
“MINFLUX data acquisition MINFLUX imaging was performed on a commercial 3D MINFLUX microscope that was driven by the Imspector software with MIN-FLUX drivers (Abberior Instruments) ( 71 ).”
Open-source sub-nanometer stabilization system for super-resolution fluorescence microscopy
Edorna, F., Choque, F. D., Ferrari, G., Masullo, L. A., Zdańkowski, P., Acuna, G. P., Tinnefeld, P., Szalai, A. M., Lopez, L. F., Zelcer, A., et al. (2025) · Light Science & Applications · doi:10.1038/s41377-025-02022-6 · Cited by 5
Boateng, E., Olsén, E., Kamanzi, A., Zhang, Y., Zhao, B., Cullis, P. R., & Leslie, S. R. (2025) · Nano Letters · doi:10.1021/acs.nanolett.5c02232 · Cited by 7
“14 The relationship between size, intensity, and mass provides additional information on structure and material composition.”
Evaluating MINFLUX experimental performance in silico
Marin, Z., & Ries, J. (2025) · Nature Communications · doi:10.1038/s41467-025-66952-w · Cited by 5
“First, it will be of use for developers, as it allows testing and optimizing new MINFLUX approaches and algorithms in silico.”
Recent progress on single-molecule localization microscopy
Gu, L., & Ji, W. (2021) · Biophysics Reports · doi:10.52601/bpr.2021.210023 · Cited by 5
“The superior spatiotemporal resolution provided by MINFLUX was also utilized to monitor the rapid molecular jumps with the measurement time as short as 400 microseconds and ~2 nm precision (Pape et al. 2020; Schmidt et al. 2021).”
Aravinth, S., Joshi, P., & Mondal, P. P. (2022) · Review of Scientific Instruments · doi:10.1063/5.0101009 · Cited by 5
Zdańkowski, P., Lopez, L. F., Acuna, G. P., & Stefani, F. D. (2022) · ACS Photonics · doi:10.1021/acsphotonics.2c01391 · Cited by 6
Flexible implementation of modulated localisation microscopy based on DMD
Illand, A., Jouchet, P., Fort, E., & Lévêque‐Fort, S. (2024) · Journal of Microscopy · doi:10.1111/jmi.13274 · Cited by 5
Parameter optimization for MINFLUX microscopy enabled single particle tracking
Vogler, B. T. L., Angelis, G. D., Zhao, Z., Eggeling, C., & Reina, F. (2025) · Communications Biology · doi:10.1038/s42003-025-09060-1 · Cited by 5
“2b – d in 9 ).”
InfluentialAnisotropic diffusion of membrane proteins at experimental timescales
Javanainen, M., Martinez‐Seara, H., Kelly, C. V., Jungwirth, P., & Fábián, B. (2021) · The Journal of Chemical Physics · doi:10.1063/5.0054973 · Cited by 5
Time Resolved Cryo‐Correlative Light and Electron Microscopy
Szabo, G. V., & Burg, T. P. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202313705 · Cited by 6
A Fast Interferometric Beam Shaper for Multi-Emitter 3D MINFLUXPreprint
Geismann, M. K., Gomez-Segalas, A., Passera, A., Shirzadian, M., & Balzarotti, F. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.12.09.570565 · Cited by 5
Alternating Electric Field‐Assisted Matrix Nano‐Coating for High Spatial Resolution MALDI Imaging
Guo, H., Li, J., Hu, H., Qin, L., Chen, L., Hao, Q., Yang, C., Wu, R., Feng, J., Liu, R., et al. (2025) · Small Methods · doi:10.1002/smtd.202500785 · Cited by 4
Mei, X., Liu, Y., Liu, X., Ma, S., Wang, C., Wang, L., Miao, Q., Chen, P., Tang, B., & Chen, G. (2025) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2025.217441 · Cited by 5
Landscape expansion microscopy reveals interactions between membrane and phase-separated organelles
Zhuang, Y., Zhang, Z., Dai, Z., & Shi, X. (2025) · The Journal of Cell Biology · doi:10.1083/jcb.202502035 · Cited by 6
Vo, H. V., 徐, R. 榕. X., Boyden, E. S., & Zhao, Y. (2026) · Nature Reviews Methods Primers · doi:10.1038/s43586-026-00480-9 · Cited by 10
“…techniques such as single-molecule localization microscopy (SMLM) 1 , stimulated emission depletion (STED) microscopy 2,3 and minimal fluorescence photon fluxes microscopy 4–8 , among others, extended the capabilities of traditional light microscopy, bringing molecular-level detail into focus.”
Membrane bridges and nanodomain partitioning govern membrane protein targeting to lipid droplets
Mizrak, A., Kæstel‐Hansen, J., Matthias, J., Harper, J. W., Hatzakis, N. S., Farese, R. V., & Walther, T. C. (2026) · Nature Cell Biology · doi:10.1038/s41556-026-01963-3 · Cited by 14
“This allowed for tracking single molecules in live cells using MINFLUX nanoscopy 14,15 (Fig.”
Tight junction structure, assembly and (dys)function
Günzel, D., Lehmann, M., & Honigmann, A. (2026) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-026-00978-w · Cited by 5
Gradual labeling with fluorogenic probes: A general method for MINFLUX imaging and tracking
Yao, L., Si, D., Chen, L., Li, S., Guan, J., Ma, J., Zhang, Q., Wang, J., Wang, L., & Gu, M. (2025) · Science Advances · doi:10.1126/sciadv.adv5971 · Cited by 8
CD16a pairs form the basal molecular subunit for the NK-cell ADCC lytic synapse
Ross, P. A., Cid, T., Quintero, M. F., Loeffler, J. R., Fatima, H., Leaman, D. P., Matthias, J., Spencer, K. S. R., Zwick, M. B., Henderson, S. C., et al. (2025) · The Journal of Immunology · doi:10.1093/jimmun/vkaf077 · Cited by 6
Plasmon-Enhanced Expansion Microscopy
Rathi, P., Gupta, P., Debnath, A., Baldi, H., Wang, Y., Gupta, R., Raman, B., & Singamaneni, S. (2023) · Nano Letters · doi:10.1021/acs.nanolett.3c01256 · Cited by 4
Introduction to bioimaging‐based spatial multi‐omic novel methods
Yan, Y., Yang, L., Meng, L., Su, H., Zhou, C., Yu, L., Li, Z., Zhang, X., Cai, H., & Gao, J. T. (2023) · Quantitative Biology · doi:10.15302/j-qb-023-0332 · Cited by 5
Ultrastructural 3D Microscopy for Biomedicine: Principles, Applications, and Perspectives
Mochalov, K. E., Korzhov, D. S., Altuninа, А. V., Агапова, О. И., & Олейников, В. А. (2024) · Acta Naturae · doi:10.32607/actanaturae.27323 · Cited by 5
FRETsael: Nanometer localization of biomolecular interactions using fluorescence lifetime imaging
Razvag, Y., Drori, P., Klemfner, S., Meshorer, E., & Lerner, E. (2025) · Biophysical Journal · doi:10.1016/j.bpj.2025.02.017 · Cited by 5
Broadband Plasmonic Nanoantennas for Multi‐Color Nanoscale Dynamics in Living Cells
Sanz‐Paz, M., van Zanten, T. S., Manzo, C., Mivelle, M., & Parajo, M. F. G. (2023) · Small · doi:10.1002/smll.202207977 · Cited by 4
Single molecule imaging unveils cellular architecture, dynamics and mechanobiology
Chen, T., & Giannone, G. (2024) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2024.102369 · Cited by 5
How does FtsZ’s treadmilling help bacterial cells divide?
Yang, X., & LIU, R. (2022) · Biocell · doi:10.32604/biocell.2022.022100 · Cited by 5
Carsten, A., Rudolph, M., Weihs, T., Schmidt, R., Wurm, C. A., Diepold, A., Failla, A. V., Wolters, M., & Aepfelbacher, M. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.09.27.461991 · Cited by 4
Self-citationClustering within a single-component biomolecular condensatePreprint
Sharma, A., Sau, A., Dave, S., Roychowdhury, S., Schnorrenberg, S., Chowdhury, R., Hutten, S., Dormann, D., & Musser, S. M. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.08.18.670948 · Cited by 5
The advantage of MINFLUX nanoscopy in single molecular tracking within living cells
Zou, H., Li, S., Kou, X., Gu, Z., & Wang, J. (2025) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545825300083 · Cited by 3
Gopinath, J. T., Gibson, E. A., Heffernan, B. M., Pierce, S. A., Saladrigas, C. A., Siemens, M. E., & Restrepo, D. (2026) · APL Photonics · doi:10.1063/5.0302521 · Cited by 5
Vogler, B. T. L., Reina, F., & Eggeling, C. (2023) · Frontiers in Bioinformatics · doi:10.3389/fbinf.2023.1268899 · Cited by 3
Phase Separation: Orchestrating Biological Adaptations to Environmental Fluctuations
Wang, W., Han, F., Qi, Z., Yan, C., Su, B., & Wang, J. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26104614 · Cited by 6
“Advances in high-resolution imaging (e.g., MINFLUX nanoscopy [163]), computational methods (AI-driven phase-field modeling [164]), and single-molecule techniques (DNA-PAINT for condensate stoichiometry [165]) will help address these gaps [166,167].”
Near-infrared MINFLUX imaging enabled by suppression of fluorophore blinking
Srambickal, C. V., Esmaeeli, H. M., Piguet, J., Reinkensmeier, L., Siegmund, R., Agostinho, A., Bates, M., Egner, A., & Widengren, J. (2025) · Science Advances · doi:10.1126/sciadv.adw3149 · Cited by 4
“2A, further details in text S6).”
Unveiling the limits of precision in iterative MINFLUX
Smith, C., Kalisvaart, D., & Prakash, K. (2024) · Journal of Microscopy · doi:10.1111/jmi.13338 · Cited by 3
Correlative nanophotonic approaches to enlighten the nanoscale dynamics of living cell membranes
Winkler, P. M., & Parajo, M. F. G. (2021) · Biochemical Society Transactions · doi:10.1042/bst20210457 · Cited by 3
Development of ultrafast camera-based imaging of single fluorescent molecules and live-cell PALMPreprint
Fujiwara, T. K., Takeuchi, S., Kalay, Z., Nagai, Y., Tsunoyama, T. A., Kalkbrenner, T., Iwasawa, K., Ritchie, K. P., Suzuki, K. G. N., & Kusumi, A. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.10.26.465864 · Cited by 3
“For molecules adsorbed on glass, it provides 2.4-nm and <20 nm localization precisions with 400- and 117-µs temporal resolutions, respectively; in live E. coli, it provides 48-nm precision with 125-µs time resolution (Balzarotti et al., 2017; Eilers et al., 2018; Schmidt et al., 2021).”
BackgroundInfluentialSpontaneously blinking fluorophores for accelerated MINFLUX nanoscopyPreprint
Remmel, M., Scheiderer, L., Butkevich, A. N., Bossi, M. L., & Hell, S. W. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.08.29.505670 · Cited by 3
Self-citationAkbergenova, Y., Matthias, J., & Littleton, J. T. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.02.03.636302 · Cited by 3
Chemicobiology tools for mapping microenvironment changes of protein condensate
Ding, W., & Shen, B. (2025) · Talanta · doi:10.1016/j.talanta.2025.128502 · Cited by 2
Polarized ATP synthase in synaptic mitochondria induced by learning and plasticity signals
Hu, Y., Wang, X., Liu, K., Xiong, S., Cai, B., Guan, J., Gu, M., & Xie, H. B. (2025) · Communications Biology · doi:10.1038/s42003-025-08963-3 · Cited by 5
“Recent advancements in single-molecule localization microscopy techniques, such as MINFLUX, offer high-resolution insights into cellular structures and molecular dynamics 24,25 .”
Pointner, A., Thalheim, D., Belasi, S., Heinen, L., Carnell, L. R., Janko, C., Tietze, R., Alexiou, C., Schneider‐Stock, R., & Nagy, R. (2026) · Advanced Materials Technologies · doi:10.1002/admt.70949 · Cited by 2
“Cell imaging is an indispensable technique in modern medical and biological research, enabling researchers to decipher complex cellular processes and quantify detailed kinetic metrics [1, 2, 3, 4].”
High-Throughput Hyperspectral and Multiplexed Super-Resolution Fluorescence Imaging by SP-STORM
Pott, E. D., Yang, M., Batey, J. E., Embree, J., & Dong, B. (2026) · JACS Au · doi:10.1021/jacsau.5c01677 · Cited by 2
Caging-group-free photoactivatable fluorophores with far-red emission
Lincoln, R., Butkevich, A. N., Gürth, C., Fischer, A., Matthias, J., Emmerich, A. R., Fidlin, M., Bossi, M. L., & Hell, S. W. (2026) · Chem · doi:10.1016/j.chempr.2025.102866 · Cited by 2
Self-citationDirect visualization of native GSDMD pores reveals lipid-driven stabilization during pyroptosis
Kappelhoff, S., Holtmannspötter, M., Schaefer, S. L., Margheritis, E. G., Asik, Ö. D., Gehle, N., Veit, H., Danial, J. S. H., Franzkoch, R., Strauss, S., et al. (2026) · Science Advances · doi:10.1126/sciadv.aee4587 · Cited by 3
“Details of the microscope and components are described in ( 73 ).”
Bodner, C., & Brameshuber, M. O. (2022) · Springer series on fluorescence · doi:10.1007/4243_2022_25 · Cited by 2
Spatiotemporal Isolation Based Super‐Resolution Microscopy†
Lu, Y., Zhao, P., & Feng, J. (2023) · Chinese Journal of Chemistry · doi:10.1002/cjoc.202200764 · Cited by 3
Watching biomolecules stride in real time
Fei, J., & Zhou, R. (2023) · Science · doi:10.1126/science.adg8451 · Cited by 3
Super-resolution microscopy reveals new insights into organelle interactions
Wu, H., Zhao, Y., Zhou, X., Wu, T., Qian, J., Wu, S., Liu, Y., & Zuo, C. (2024) · Advanced imaging. · doi:10.3788/ai.2024.20004 · Cited by 2
Single-molecule DNA dynamics with graphene energy transfer
Kosuri, P. (2024) · Nature Methods · doi:10.1038/s41592-024-02560-8 · Cited by 2
Aravinth, S., Zanacchi, F. C., & Mondal, P. P. (2024) · Communications Biology · doi:10.1038/s42003-024-07153-x · Cited by 3
“…accumulation for imaging in nanoscale topography (PAINT) 25,26 , simultaneous multiplane imaging-based localization encoded (SMILE) 27,28 , individual molecule localization-selective plane illumination microscopy (IML-SPIM) 22 , MINFLUX 18 ,POSSIBLE microscopy, scanning SMLM 29 and others 30 – 37 .”
InfluentialWong, T. H., Khater, I. M., Hallgrimson, C., Li, Y. L., Hamarneh, G., & Nabi, I. R. (2025) · Journal of Cell Science · doi:10.1242/jcs.263570 · Cited by 2
Thompson, A.-L. C., Wopereis, J. L. M., Tekle, Y. I., & Katz, L. A. (2025) · Microscopy and Microanalysis · doi:10.1093/mam/ozaf017 · Cited by 2
Hassan, M., Kaifer, B., Christian, T., Quaas, X. T., Mueller, J., & Boehm, H. (2025) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2025.1596955 · Cited by 3
Single-molecule Tracking and Kinetic Analysis in Living Cells and Multicellular Organisms
Gebhardt, J. C. M. (2025) · Journal of Molecular Biology · doi:10.1016/j.jmb.2025.169308 · Cited by 5
On‐Target Photoassembly of Pyronin Dyes for Super‐Resolution Microscopy
Knorr, G., Bossi, M. L., & Hell, S. W. (2025) · Angewandte Chemie International Edition · doi:10.1002/anie.202506894 · Cited by 4
“[59, 60] The super-resolution images can clearly discern Tomm20 clusters in the mitochondrial membrane, otherwise undiscernible in conventional images.”
Self-citationCharting the nanotopography of inner hair cell synapses using MINFLUX nanoscopy
Kapoor, R., Kim, H., Garlick, E., Lima, M. A. D. R. B. F., Esch, K., Ruhwedel, T., Möbius, W., Wolf, F., & Moser, T. (2025) · Science Advances · doi:10.1126/sciadv.ady4344 · Cited by 3
“Imaging was performed on an Abberior 3D MINFLUX system (Abberior Instruments), as described before ( 113 ).”
Begarani, F., D’Autilia, F., Ferri, G., Pesce, L., Azzarello, F., Lorenzi, V. D., Durso, W., Grosso, A. D., Cecchini, M. G., & Cardarelli, F. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23147623 · Cited by 3
“More recently, a straightforward combination of STED and local excitation-intensity zeros for localizing emitters was proposed, pushing 3D localization experiments to unprecedented spatial (~1 nanometer) and temporal (~100 ms) resolutions [13–15], even in a standard fluorescence microscope [16].”
BackgroundFrom the beginnings to multidimensional light and electron microscopy of virus morphogenesis
Sanders, S., Jensen, Y., Reimer, R., & Bosse, J. B. (2023) · Advances in virus research · doi:10.1016/bs.aivir.2023.05.001 · Cited by 3
Weisong, 赵. Z., Yuanyuan, 黄. H., Zhenqian, 韩. H., Liying, 曲. Q., Haoyu, 李. L., & Chen, L. (2024) · Chinese Journal of Lasers · doi:10.3788/cjl231214 · Cited by 3
Assessment of 3D MINFLUX data for quantitative structural biology in cells revisitedPreprint
Gwosch, K. C., Balzarotti, F., Pape, J. K., Hoess, P., Ellenberg, J., Ries, J., Matti, U., Schmidt, R., Sahl, S. J., & Hell, S. W. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.05.13.491065 · Cited by 2
Self-citationReal-time single-molecule 3D tracking in E. coli based on cross-entropy minimizationPreprint
Amselem, E., Broadwater, D. W. B., Hävermark, T., Johansson, M., & Elf, J. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.08.25.505330 · Cited by 2
A Two-Heads-Bound State Drives KIF1A SuperprocessivityPreprint
Rao, L., Wirth, J. O., Matthias, J., & Gennerich, A. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.01.14.632505 · Cited by 1
Event-triggered MINFLUX microscopy: smart microscopy to catch and follow rare eventsPreprint
Alvelid, J., Koerfer, A., & Eggeling, C. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.08.27.672674 · Cited by 2
Metadata
- Authors
- Schmidt, R., Weihs, T., Wurm, C. A., Jansen, I., Rehman, J., Sahl, S. J., & Hell, S. W.
- Affiliations
- Max Planck Institute for Biophysical Chemistry (DE)
- Max Planck Institute for Medical Research (DE)
- Corresponding author
- Schmidt, Roman
- Hell, Stefan W.
- ORCID
- Venue
- Nature Communications
- Published
- 2021-03-05
- Volume
- 12
- Issue
- 1
- Pages
- 1478-1478
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC7935904
- OpenAlex
- W3133879440
- Semantic Scholar
- 13f2120c5dbbf236db124fdaf5a4f3cc72466f6e
- Cited by
- 306
- References
- 34
- Citations by year
- 2026: 41 · 2025: 94 · 2024: 57 · 2023: 58 · 2022: 41 · 2021: 15
- FWCI
- 19.49
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) (submittedVersion, cc-by)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Funders
- European Molecular Biology Laboratory
- Bundesministerium für Bildung und Forschung (13N14122)
- Max-Planck-Gesellschaft
- Freie Universität Berlin
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Keywords
- MINFLUX, single-molecule localization, single-molecule fluorescence microscopy, beam steering, sample stabilization, single-molecule tracking
- MeSH terms
- Diffusion, Equipment Design, Fluorescence, Fluorescent Dyes, Image Processing, Computer-Assisted, Microscopy, Fluorescence, Photons, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.