A rapid, accurate, scalable, and portable testing system for COVID-19 diagnosis
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The need for rapid, accurate, and scalable testing systems for COVID-19 diagnosis is clear and urgent. Here, we report a rapid S calable and Po rtable T esting (SPOT) system consisting of a rapid, highly sensitive, and accurate assay and a battery-powered portable device for COVID-19 diagnosis. The SPOT assay comprises a one-pot reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) followed by Pf Ago-based target sequence detection. It is capable of detecting the N gene and E gene in a multiplexed reaction with the limit of detection (LoD) of 0.44 copies/μL and 1.09 copies/μL, respectively, in SARS-CoV-2 virus-spiked saliva samples within 30 min. Moreover, the SPOT system is used to analyze 104 clinical saliva samples and identified 28/30 (93.3% sensitivity) SARS-CoV-2 positive samples (100% sensitivity if LoD is considered) and 73/74 (98.6% specificity) SARS-CoV-2 negative samples. This combination of speed, accuracy, sensitivity, and portability will enable high-volume, low-cost access to areas in need of urgent COVID-19 testing capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
To, K. K.-W., Tsang, O. T.-Y., Leung, W.-S., Tam, A. R., Wu, T.-C., Lung, D. C., Yip, C. C.-Y., Cai, J.-P., Chan, J. M.-C., Chik, T. S.-H., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30196-1 · Cited by 3,066
CRISPR–Cas12-based detection of SARS-CoV-2
Broughton, J. P., Deng, X., Yu, G., Fasching, C. L., Servellita, V., Singh, J., Miao, X., Streithorst, J. A., Granados, A., Sotomayor-Gonzalez, A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0513-4 · Cited by 2,717 · cited 1×
“The SPOT device can export data via a USB cable (5) and be recharged.”
MethodConsistent Detection of 2019 Novel Coronavirus in Saliva
To, K. K.-W., Tsang, O. T.-Y., Yip, C. C.-Y., Chan, K.-H., Wu, T.-C., Chan, J. M.-C., Leung, W.-S., Chik, T. S.-H., Choi, C. Y.-C., Kandamby, D. H., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa149 · Cited by 1,873
Test sensitivity is secondary to frequency and turnaround time for COVID-19 screening
Larremore, D. B., Wilder, B., Lester, E., Shehata, S., Burke, J. M., Hay, J. A., Tambe, M., Mina, M. J., & Parker, R. (2021) · Science Advances · doi:10.1126/sciadv.abd5393 · Cited by 1,216
Saliva or Nasopharyngeal Swab Specimens for Detection of SARS-CoV-2
Wyllie, A. L., Fournier, J., Casanovas-Massana, A., Campbell, M., Tokuyama, M., Vijayakumar, P., Warren, J. L., Geng, B., Muenker, M. C., Moore, A. J., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2016359 · Cited by 1,169
Analytical sensitivity and efficiency comparisons of SARS-CoV-2 RT–qPCR primer–probe sets
Vogels, C. B. F., Brito, A. F., Wyllie, A. L., Fauver, J. R., Ott, I. M., Kalinich, C. C., Petrone, M. E., Casanovas-Massana, A., Catherine Muenker, M., Moore, A. J., et al. (2020) · Nature Microbiology · doi:10.1038/s41564-020-0761-6 · Cited by 876
Detection of SARS-CoV-2 with SHERLOCK One-Pot Testing
Joung, J., Ladha, A., Saito, M., Kim, N.-G., Woolley, A. E., Segel, M., Barretto, R. P. J., Ranu, A., Macrae, R. K., Faure, G., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2026172 · Cited by 773
Recent advances and perspectives of nucleic acid detection for coronavirus
Shen, M., Zhou, Y., Ye, J., Abdullah AL-maskri, A. A., Kang, Y., Zeng, S., & Cai, S. (2020) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2020.02.010 · Cited by 520 · cited 1×
“to power on the device (1) and start detection reactions (2) and read results on the integrated LCD screen (3).”
BackgroundRapid Molecular Detection of SARS-CoV-2 (COVID-19) Virus RNA Using Colorimetric LAMP
Zhang, Y., Odiwuor, N., Xiong, J., Sun, L., Nyaruaba, R. O., Wei, H., & Tanner, N. A. (2020) · medRxiv · doi:10.1101/2020.02.26.20028373 · Cited by 355
Cited by
Advanced Point‐of‐Care Testing Technologies for Human Acute Respiratory Virus Detection
Zhang, Z., Ma, P., Ahmed, R., Wang, J., Akin, D., Soto, F., Liu, B., Li, P., & Demirci, U. (2022) · Advanced Materials · doi:10.1002/adma.202103646 · Cited by 231
Simplified Cas13-based assays for the fast identification of SARS-CoV-2 and its variants
Arizti-Sanz, J., Bradley, A., Zhang, Y. B., Boehm, C. K., Freije, C. A., Grunberg, M. E., Kosoko-Thoroddsen, T.-S. F., Welch, N. L., Pillai, P. P., Mantena, S., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00889-z · Cited by 230
Towards hospital-on-chip supported by 2D MXenes-based 5th generation intelligent biosensors
Chaudhary, V., Khanna, V., Ahmed Awan, H. T., Singh, K., Khalid, M., Mishra, Y. K., Bhansali, S., Li, C.-Z., & Kaushik, A. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114847 · Cited by 176
“Guanhua et al. (Xun et al., 2021) reported the fabrication of the most accessible and most scalable testing system for COVID-19 detection, which includes the rapid, entirely accurate and sensitive assay likely to battery-based portable powdered devices.”
BackgroundMethodZheng, L., Zhou, B., Yang, Y., Zan, B., Zhong, B., Wu, B., Feng, Y., Liu, Q., & Hong, L. (2024) · Chemical Science · doi:10.1039/d3sc06221j · Cited by 11
Zheng, L., Zan, B., Yang, Y., Zhou, B., Wu, B., Feng, Y., Liu, Q., & Hong, L. (2023) · doi:10.1101/2023.06.28.546964 · Cited by 11
Metadata
- Authors
- Xun, G., Lane, S. T., Petrov, V. A., Pepa, B. E., & Zhao, H.
- Venue
- Nature Communications
- Published
- 2021-05-18
- Volume
- 12
- Issue
- 1
- Pages
- 2905-2905
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3163423704
- Cited by
- 180
- References
- 19
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.