Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 329

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Self-rechargeable cardiac pacemaker system with triboelectric nanogenerators

Open access
Ryu, Hanjun, Park, Hyun-moon, Kim, Moo-Kang, Kim, Bosung, Myoung, Hyoun Seok, Kim, Tae Yun, Yoon, Hong-Joon, Kwak, Sung Soo, Kim, Jihye, Hwang, Tae Ho, Choi, Eue-Keun, Kim, Sang-Woo·2021·Nature Communications

Abstract

Self-powered implantable devices have the potential to extend device operation time inside the body and reduce the necessity for high-risk repeated surgery. Without the technological innovation of in vivo energy harvesters driven by biomechanical energy, energy harvesters are insufficient and inconvenient to power titanium-packaged implantable medical devices. Here, we report on a commercial coin battery-sized high-performance inertia-driven triboelectric nanogenerator (I-TENG) based on body motion and gravity. We demonstrate that the enclosed five-stacked I-TENG converts mechanical energy into electricity at 4.9 μW/cm 3 (root-mean-square output). In a preclinical test, we show that the device successfully harvests energy using real-time output voltage data monitored via Bluetooth and demonstrate the ability to charge a lithium-ion battery. Furthermore, we successfully integrate a cardiac pacemaker with the I-TENG, and confirm the ventricle pacing and sensing operation mode of the self-rechargeable cardiac pacemaker system. This proof-of-concept device may lead to the development of new self-rechargeable implantable medical devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-021-24417-w

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 329

Metadata

Authors
Ryu, H., Park, H.-M., Kim, M.-K., Kim, B., Myoung, H. S., Kim, T. Y., Yoon, H.-J., Kwak, S. S., Kim, J., Hwang, T. H., Choi, E.-K., & Kim, S.-W.
Venue
Nature Communications
Published
2021-07-16
Volume
12
Issue
1
Pages
4374-4374
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3178104101
Cited by
329
References
34
FWCI
15.47
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-rechargeable cardiac pacemaker system with triboelectric nanogenerators. https://app.cochat.ai/papers/10.1038/s41467-021-24417-w
The paper
Ryu, H., Park, H.-M., Kim, M.-K., Kim, B., Myoung, H. S., Kim, T. Y., Yoon, H.-J., Kwak, S. S., Kim, J., Hwang, T. H., Choi, E.-K., & Kim, S.-W. (2021). Self-rechargeable cardiac pacemaker system with triboelectric nanogenerators. Nature Communications. https://doi.org/10.1038/s41467-021-24417-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.