Adaptive wireless millirobotic locomotion into distal vasculature
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Microcatheters have enabled diverse minimally invasive endovascular operations and notable health benefits compared with open surgeries. However, with tortuous routes far from the arterial puncture site, the distal vascular regions remain challenging for safe catheter access. Therefore, we propose a wireless stent-shaped magnetic soft robot to be deployed, actively navigated, used for medical functions, and retrieved in the example M4 segment of the middle cerebral artery. We investigate shape-adaptively controlled locomotion in phantoms emulating the physiological conditions here, where the lumen diameter shrinks from 1.5 mm to 1 mm, the radius of curvature of the tortuous lumen gets as small as 3 mm, the lumen bifurcation angle goes up to 120°, and the pulsatile flow speed reaches up to 26 cm/s. The robot can also withstand the flow when the magnetic actuation is turned off. These locomotion capabilities are confirmed in porcine arteries ex vivo. Furthermore, variants of the robot could release the tissue plasminogen activator on-demand locally for thrombolysis and function as flow diverters, initiating promising therapies towards acute ischemic stroke, aneurysm, arteriovenous malformation, dural arteriovenous fistulas, and brain tumors. These functions should facilitate the robot’s usage in new distal endovascular operations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age-related vascular stiffening: causes and consequences
Kohn, J. C., Lampi, M. C., & Reinhart-King, C. A. (2015) · Frontiers in Genetics · doi:10.3389/fgene.2015.00112 · Cited by 440
Cited by
Magnetic soft microfiberbots for robotic embolization
Liu, X., Wang, L., Xiang, Y., Liao, F., Li, N., Li, J., Wang, J., Wu, Q., Zhou, C., Yang, Y., et al. (2024) · Science Robotics · doi:10.1126/scirobotics.adh2479 · Cited by 213
Dexterous helical magnetic robot for improved endovascular access
Dreyfus, R., Boehler, Q., Lyttle, S., Gruber, P., Lussi, J., Chautems, C., Gervasoni, S., Berberat, J., Seibold, D., Ochsenbein-Kölble, N., et al. (2024) · Science Robotics · doi:10.1126/scirobotics.adh0298 · Cited by 185
Peng, Q., Wang, S., Han, J., Huang, C., Yu, H., Li, D., Qiu, M., Cheng, S., Wu, C., Cai, M., et al. (2024) · Research · doi:10.34133/research.0339 · Cited by 89
Zhang, M., Yang, L., Yang, H., Su, L., Xue, J., Wang, Q., Hao, B., Jiang, Y., Chan, K. F., Sung, J. J. Y., et al. (2025) · Science Advances · doi:10.1126/sciadv.adv1682 · Cited by 36
Metadata
- Authors
- Wang, T., Ugurlu, H., Yan, Y., Li, M., Li, M., Wild, A.-M., Yildiz, E., Schneider, M., Sheehan, D., Hu, W., & Sitti, M.
- Venue
- Nature Communications
- Published
- 2022-08-01
- Volume
- 13
- Issue
- 1
- Pages
- 4465-4465
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4289334797
- Cited by
- 138
- References
- 1
- FWCI
- 7.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive wireless millirobotic locomotion into distal vasculature. https://app.cochat.ai/papers/10.1038/s41467-022-32059-9
- The paper
- Wang, T., Ugurlu, H., Yan, Y., Li, M., Li, M., Wild, A.-M., Yildiz, E., Schneider, M., Sheehan, D., Hu, W., & Sitti, M. (2022). Adaptive wireless millirobotic locomotion into distal vasculature. Nature Communications. https://doi.org/10.1038/s41467-022-32059-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.