CoChat

Magnetic soft microfiberbots for robotic embolization

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

Abstract

Cerebral aneurysms and brain tumors are leading life-threatening diseases worldwide. By deliberately occluding the target lesion to reduce the blood supply, embolization has been widely used clinically to treat cerebral aneurysms and brain tumors. Conventional embolization is usually performed by threading a catheter through blood vessels to the target lesion, which is often limited by the poor steerability of the catheter in complex neurovascular networks, especially in submillimeter regions. Here, we propose magnetic soft microfiberbots with high steerability, reliable maneuverability, and multimodal shape reconfigurability to perform robotic embolization in submillimeter regions via a remote, untethered, and magnetically controllable manner. Magnetic soft microfiberbots were fabricated by thermal drawing magnetic soft composite into microfibers, followed by magnetizing and molding procedures to endow a helical magnetic polarity. By controlling magnetic fields, magnetic soft microfiberbots exhibit reversible elongated/aggregated shape morphing and helical propulsion in flow conditions, allowing for controllable navigation through complex vasculature and robotic embolization in submillimeter regions. We performed in vitro embolization of aneurysm and tumor in neurovascular phantoms and in vivo embolization of a rabbit femoral artery model under real-time fluoroscopy. These studies demonstrate the potential clinical value of our work, paving the way for a robotic embolization scheme in robotic settings.

Overview

Integrity signals

Registry

Crossref · 10.1126/scirobotics.adh2479

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 55 references

Cited by

See all 227

Metadata

Authors
Liu, X., Wang, L., Xiang, Y., Liao, F., Li, N., Li, J., Wang, J., Wu, Q., Zhou, C., Yang, Y., Kou, Y., Yang, Y., Tang, H., Zhou, N., Wan, C., Yin, Z., Yang, G.-Z., Tao, G., & Zang, J.
Affiliations
  • Wuhan National Laboratory for Optoelectronics (CN)
  • University of Science and Technology of China (CN)
  • Tongji Hospital (CN)
  • Wuhan Union Hospital (CN)
  • State Key Laboratory of Digital Manufacturing Equipment and Technology (CN)
  • Shanghai Jiao Tong University (CN)
Corresponding author
  • Liu, Xurui
  • Wang, Liu
  • Xiang, Yuanzhuo
  • Yang, Guang-Zhong
  • Tao, Guangming
  • Zang, Jianfeng
Venue
Science Robotics
Published
2024-02-21
Volume
9
Issue
87
Pages
eadh2479-eadh2479
ISSN
2470-9476 (ISSN-L)
OpenAlex
W4391992477
Cited by
213
References
55
Citations by year
2026: 81 · 2025: 98 · 2024: 34
FWCI
30.70
Type
journal article
Language
en
Open access
closed
Locations
  • Science Robotics (publishedVersion)
  • PubMed (publishedVersion)
  • 中国科学院力学研究所 (submittedVersion)
Funders
National Natural Science Foundation of China (11272369, AND 62175082, 51820105008, 52188102, 2022YFC2408100, 51572096)
Topics
  • Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Micro and Nano Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
Keywords
intracranial aneurysm, brain tumors, shape morphing, fluoroscopic guidance
MeSH terms
Animals, Brain Neoplasms, Intracranial Aneurysm, Rabbits, Robotics, Magnetic Phenomena, Robotic Surgical Procedures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic soft microfiberbots for robotic embolization. https://app.cochat.ai/papers/10.1126/scirobotics.adh2479
The paper
Liu, X., Wang, L., Xiang, Y., Liao, F., Li, N., Li, J., Wang, J., Wu, Q., Zhou, C., Yang, Y., Kou, Y., Yang, Y., Tang, H., Zhou, N., Wan, C., Yin, Z., Yang, G.-Z., Tao, G., & Zang, J. (2024). Magnetic soft microfiberbots for robotic embolization. Science Robotics. https://doi.org/10.1126/scirobotics.adh2479

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.