CoChat

A compliant metastructure design with reconfigurability up to six degrees of freedom

Open access

The DOI matches its Crossref record; 67 of the 68 references it cites were found in a registry or an index.

Abstract

Compliant mechanisms with reconfigurable degrees of freedom are gaining attention in the development of kinesthetic haptic devices, robotic systems, and mechanical metamaterials. However, available devices exhibit limited programmability and form-customizability, restricting their versatility. To address this gap, we propose a metastructure concept featuring reconfigurable motional freedom and tunable stiffness, adaptable to various form factors and applications. These devices incorporate passive flexures and actively stiffness-changing rods to modify kinematic freedom. A rational design pipeline informs the flexures’ topological arrangements, geometric parameters, and control signals based on targeted mobilities, enabling the creation of unitary joints with up to six degrees of freedom. Our demonstrative application examples include a wrist device that has an effective stiffness of 0.370 Nm/deg (unlocked state, 5% displacement) to 2.278 Nm/deg (locked state, 1% displacement) to enable dynamic joint mobility control, a haptic thimble device (2.27-52.815 Nmm −1 at 1% displacement) that mimics the sensation of touching physical materials ranging from soft gel to metal surfaces, and a wearable device composed of multiple joints tailored for the arm and hand to augment haptic experiences or facilitate muscle training. We believe the presented method can help democratize compliant metastructures development and expand their versatility for broader contexts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-024-55591-2

Cites

67 of 67 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Kinematically reconfigurable compliant metastructure design and envisioned application examples. a Design of stiffness-changing materials for making compliant metastructures that can change their kinematics depending on the context of use and their screw algebra representation. DOF (degree of freedom), DOC (degree of constraint). b A benchmark of devices presented in this work and literature with respect to the number of programmable DOF and the range of afforded effective stiffness19–28. The range of stiffness needed for upper limb wearable kinesthetic haptic design is exemplified by the vertical dashed lines. JND (just noticeable difference), LMPA (low melting point alloy) 20, PET (polyethylene terephthalate)21, PC (polycarbonate)21, CFM (constant force mechanism)26. c Exemplary design space enabled by reconfigurable kinesthetic haptic device leveraging DOF locking/unlocking and stiffness changes, including (i) virtual kinematic feedback, (ii) selective muscle group training, (iii) context-adaptive rehabilitation braces, and (iv) wearable haptic proxies. d The device can disable the forearm’s rotation to, e.g., simulate the experience of turning a locked vs. unlocked doorknob e The kinematic reconfiguration can selectively constrain finger interphalangeal joints, allowing for targeted muscle group training. MP (metacarpophalangeal) joint, DIP (distal interphalangeal) joint, PIP (proximal interphalangeal) joint. f The wrist device can function as a context-adaptive wrist brace (e.g., for alleviating wrist-tunnel syndrome) that can reconfigure its kinematic constraint to enable certain motions. g A haptic thimble device can proxy the haptic experience of pressing different materials by reconfiguring its stiffness.
Fig. 1 Kinematically reconfigurable compliant metastructure design and envisioned application examples. a Design of stiffness-changing materials for making compliant metastructures that can change their kinematics depending on the context of use and their screw algebra representation. DOF (degree of freedom), DOC (degree of constraint). b A benchmark of devices presented in this work and literature with respect to the number of programmable DOF and the range of afforded effective stiffness19–28. The range of stiffness needed for upper limb wearable kinesthetic haptic design is exemplified by the vertical dashed lines. JND (just noticeable difference), LMPA (low melting point alloy) 20, PET (polyethylene terephthalate)21, PC (polycarbonate)21, CFM (constant force mechanism)26. c Exemplary design space enabled by reconfigurable kinesthetic haptic device leveraging DOF locking/unlocking and stiffness changes, including (i) virtual kinematic feedback, (ii) selective muscle group training, (iii) context-adaptive rehabilitation braces, and (iv) wearable haptic proxies. d The device can disable the forearm’s rotation to, e.g., simulate the experience of turning a locked vs. unlocked doorknob e The kinematic reconfiguration can selectively constrain finger interphalangeal joints, allowing for targeted muscle group training. MP (metacarpophalangeal) joint, DIP (distal interphalangeal) joint, PIP (proximal interphalangeal) joint. f The wrist device can function as a context-adaptive wrist brace (e.g., for alleviating wrist-tunnel syndrome) that can reconfigure its kinematic constraint to enable certain motions. g A haptic thimble device can proxy the haptic experience of pressing different materials by reconfiguring its stiffness.CC BY · PubMed Central
Fig. 2 Algorithm for designing kinematically reconfigurable compliant mechanisms using the wrist joint as an example. a The algorithm starts by computing the (i) freedom and (ii) constraint space of deviation and flexion. (iii) The subspace for passive flexures is the intersection of all modal constraint spaces. In this design case, any rod flexure whose extended axis passes through the center point or lies on the plane spanned by the two degrees of freedom axes is permitted. (iv) The relative complements represent the rod placements required to exactly constrain the other mode. In this case, any flexure that does not pass through and is not parallel to the rotation axis is allowed. Next, minimal (v) non-redundant flexures should be added to span the constraint subspaces and exactly constrain each kinematic mode. In this case, four conventional flexures and two stiffness-changing flexures are used (one for each mode). DOF (degree of freedom), DOC (degree of constraint). b The overall design workflow for reconfigurable embodied haptic devices. (vi) The input kinematic specifications are supplied to the algorithm (a) to find (vii) the parametric flexure placement. Based on the kinetics design goals (e.g., stiffness), (viii) more flexures could then be added to the design and use (ix) an analytical stiffness model and (x) finite element simulation to validate and iterate the design (color indicates the equivalent strain in ANSYS). In this sequence, the passive flexures from (v) are replaced by the wrist joint’s skeleton to produce (vii), then more flexures are added, and their geometric parameters are altered to produce a device with the targeted kinetic performance. c The final design was created by remodeling the rigid stages in (viii) to provide a good fit to the wearer and connections between flexures. d The design’s Venn diagram representation and the membership of each space in (a). e Reconfiguration for the kinematic modes: the complement constraint subspace should be canceled by softening the flexures to enable (xi) flexion and (xii) deviation.
Fig. 2 Algorithm for designing kinematically reconfigurable compliant mechanisms using the wrist joint as an example. a The algorithm starts by computing the (i) freedom and (ii) constraint space of deviation and flexion. (iii) The subspace for passive flexures is the intersection of all modal constraint spaces. In this design case, any rod flexure whose extended axis passes through the center point or lies on the plane spanned by the two degrees of freedom axes is permitted. (iv) The relative complements represent the rod placements required to exactly constrain the other mode. In this case, any flexure that does not pass through and is not parallel to the rotation axis is allowed. Next, minimal (v) non-redundant flexures should be added to span the constraint subspaces and exactly constrain each kinematic mode. In this case, four conventional flexures and two stiffness-changing flexures are used (one for each mode). DOF (degree of freedom), DOC (degree of constraint). b The overall design workflow for reconfigurable embodied haptic devices. (vi) The input kinematic specifications are supplied to the algorithm (a) to find (vii) the parametric flexure placement. Based on the kinetics design goals (e.g., stiffness), (viii) more flexures could then be added to the design and use (ix) an analytical stiffness model and (x) finite element simulation to validate and iterate the design (color indicates the equivalent strain in ANSYS). In this sequence, the passive flexures from (v) are replaced by the wrist joint’s skeleton to produce (vii), then more flexures are added, and their geometric parameters are altered to produce a device with the targeted kinetic performance. c The final design was created by remodeling the rigid stages in (viii) to provide a good fit to the wearer and connections between flexures. d The design’s Venn diagram representation and the membership of each space in (a). e Reconfiguration for the kinematic modes: the complement constraint subspace should be canceled by softening the flexures to enable (xi) flexion and (xii) deviation.CC BY · PubMed Central
Fig. 3 A compliant mechanism joint that can be reconfigured to provide mobility along each and any of the six degrees of freedom (DOF) in the three-dimensional space. a The device consists of two identical stages connected by nine stiffness-changing flexural rods lying on three orthogonal planes passing through the center of rotation (red dot). Scale bar, 20 mm. b The Venn diagram showing the constraint subspaces calculated from the algorithm and the affinity of each rod (Supplementary Note 2.5). c The device’s motion along each of the DOF (top row) and the corresponding flexural rod configuration (bottom row, orange: heated, blue: cold). The dashed and solid lines show the mobile stage’s centerline position before and after displacement, respectively, with the arrow showing the direction of motion. Scale bar, 10 mm. d The load-displacement plots of each DOF in the locked (blue) and unlocked (orange) states. Data are means ± s.d. n = 3 samples. e 1% (1 mm) displacement loads for each DOF. Statistically significant differences were found between toggled modes using t-tests (***p < 0.001). Data are means ± s.d. n = 3 samples.
Fig. 3 A compliant mechanism joint that can be reconfigured to provide mobility along each and any of the six degrees of freedom (DOF) in the three-dimensional space. a The device consists of two identical stages connected by nine stiffness-changing flexural rods lying on three orthogonal planes passing through the center of rotation (red dot). Scale bar, 20 mm. b The Venn diagram showing the constraint subspaces calculated from the algorithm and the affinity of each rod (Supplementary Note 2.5). c The device’s motion along each of the DOF (top row) and the corresponding flexural rod configuration (bottom row, orange: heated, blue: cold). The dashed and solid lines show the mobile stage’s centerline position before and after displacement, respectively, with the arrow showing the direction of motion. Scale bar, 10 mm. d The load-displacement plots of each DOF in the locked (blue) and unlocked (orange) states. Data are means ± s.d. n = 3 samples. e 1% (1 mm) displacement loads for each DOF. Statistically significant differences were found between toggled modes using t-tests (***p < 0.001). Data are means ± s.d. n = 3 samples.CC BY · PubMed Central
Fig. 4 Tailored design for wearable kinesthetic haptics. a Picture of a device for the arm to toggle individual joint degree of freedom (DOF). MP (metacarpophalangeal) joint, DIP (distal interphalangeal) joint, PIP (proximal interphalangeal) joint. Scale bar, 50 mm. b Pictures of the unlocked forearm joint (i) before and (ii) after pronation. Scale bar, 50 mm. c Pictures of the unlocked finger joints (iii) before and (iv) after flexion. Scale bar, 50 mm. d Pictures of the wrist joint exercising along the unlocked (v) flexion, (vi) deviation, and (vii) both directions. Scale bar, 50 mm. e The load-displacement plots of the wrist joint device’s (viii) flexion and (ix) deviation DOF under different configuration modes. JND (just noticeable difference). Data are means ± s.d. n = 3 repetitions. Dashed lines are finite element simulation results. f Stiffness comparison of the wrist joint device under different configuration modes against the (x) flexion and (xi) deviation DOF. The effective stiffness was calculated as load/displacement at the experiment criteria (i.e., torque limit load for locked states and JND limits for unlocked states). Data are means ± s.d. n = 3 repetitions.
Fig. 4 Tailored design for wearable kinesthetic haptics. a Picture of a device for the arm to toggle individual joint degree of freedom (DOF). MP (metacarpophalangeal) joint, DIP (distal interphalangeal) joint, PIP (proximal interphalangeal) joint. Scale bar, 50 mm. b Pictures of the unlocked forearm joint (i) before and (ii) after pronation. Scale bar, 50 mm. c Pictures of the unlocked finger joints (iii) before and (iv) after flexion. Scale bar, 50 mm. d Pictures of the wrist joint exercising along the unlocked (v) flexion, (vi) deviation, and (vii) both directions. Scale bar, 50 mm. e The load-displacement plots of the wrist joint device’s (viii) flexion and (ix) deviation DOF under different configuration modes. JND (just noticeable difference). Data are means ± s.d. n = 3 repetitions. Dashed lines are finite element simulation results. f Stiffness comparison of the wrist joint device under different configuration modes against the (x) flexion and (xi) deviation DOF. The effective stiffness was calculated as load/displacement at the experiment criteria (i.e., torque limit load for locked states and JND limits for unlocked states). Data are means ± s.d. n = 3 repetitions.CC BY · PubMed Central
Fig. 5 A tailored design of embodied haptics proxy. a Pictures (from left to right) of the haptic thimble simulating the stiffness of pressing on a block of aluminum stock, polyurethane foam, and a block of jelly. Scale bar, 10 mm. b The device design schema. All rods have an outer diameter (OD) of 1.5 mm unless specified otherwise. c The load-displacement plots of the thimble under different configurations. The five numbers making up the name of each sample indicate the states of flexure groups 1-5 in (b) with 1 indicating softening and 0 for hardening. Data are means ± s.d. n = 3 samples. Dashed lines are FE simulation results. d The device simulates different levels of stiffness within the design parameters, spanning two orders of magnitudes. Data are means ± s.d. n = 3 samples. e Flexure configurations (top row) and pictures of deformed flexures (bottom row) under three modes: [0, 0, 0, 0, 0] being fully rigid, [0, 1, 0, 0, 1] being partially softened, and [1, 1, 1, 1, 1] being fully softened. Scale bar, 10 mm.
Fig. 5 A tailored design of embodied haptics proxy. a Pictures (from left to right) of the haptic thimble simulating the stiffness of pressing on a block of aluminum stock, polyurethane foam, and a block of jelly. Scale bar, 10 mm. b The device design schema. All rods have an outer diameter (OD) of 1.5 mm unless specified otherwise. c The load-displacement plots of the thimble under different configurations. The five numbers making up the name of each sample indicate the states of flexure groups 1-5 in (b) with 1 indicating softening and 0 for hardening. Data are means ± s.d. n = 3 samples. Dashed lines are FE simulation results. d The device simulates different levels of stiffness within the design parameters, spanning two orders of magnitudes. Data are means ± s.d. n = 3 samples. e Flexure configurations (top row) and pictures of deformed flexures (bottom row) under three modes: [0, 0, 0, 0, 0] being fully rigid, [0, 1, 0, 0, 1] being partially softened, and [1, 1, 1, 1, 1] being fully softened. Scale bar, 10 mm.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 67 references

Cited by

See all 17

Metadata

Authors
Yang, H., Patel, D. K., Johnson, T., Zhong, K., Olson, G., Majidi, C., Islam, M. F., Zhang, T., & Yao, L.
Affiliations
  • Carnegie Mellon University (US)
  • University of Massachusetts Amherst (US)
  • Syracuse University (US)
Corresponding author
  • Zhang, Teng
  • Yao, Lining
Venue
Nature Communications
Published
2025-01-16
Volume
16
Issue
1
Pages
719-719
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4406427206
Cited by
17
References
68
Citations by year
2026: 9 · 2025: 8
FWCI
4.91
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Science Foundation (IIS-CAREER-1847149, IIS-2118924)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
Keywords
compliant mechanisms, tunable stiffness, haptic devices, mechanical metamaterials, wearable haptic device, muscle training

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A compliant metastructure design with reconfigurability up to six degrees of freedom. https://app.cochat.ai/papers/10.1038/s41467-024-55591-2
The paper
Yang, H., Patel, D. K., Johnson, T., Zhong, K., Olson, G., Majidi, C., Islam, M. F., Zhang, T., & Yao, L. (2025). A compliant metastructure design with reconfigurability up to six degrees of freedom. Nature Communications. https://doi.org/10.1038/s41467-024-55591-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.