Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.

Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation

Abstract

We describe the design and control of a wearable robotic device powered by pneumatic artificial muscle actuators for use in ankle-foot rehabilitation. The design is inspired by the biological musculoskeletal system of the human foot and lower leg, mimicking the morphology and the functionality of the biological muscle-tendon-ligament structure. A key feature of the device is its soft structure that provides active assistance without restricting natural degrees of freedom at the ankle joint. Four pneumatic artificial muscles assist dorsiflexion and plantarflexion as well as inversion and eversion. The prototype is also equipped with various embedded sensors for gait pattern analysis. For the subject tested, the prototype is capable of generating an ankle range of motion of 27° (14° dorsiflexion and 13° plantarflexion). The controllability of the system is experimentally demonstrated using a linear time-invariant (LTI) controller. The controller is found using an identified LTI model of the system, resulting from the interaction of the soft orthotic device with a human leg, and model-based classical control design techniques. The suitability of the proposed control strategy is demonstrated with several angle-reference following experiments.

Overview

Integrity signals

Registry

Crossref · 10.1088/1748-3182/9/1/016007

Cites

65 of 65 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 65 references

Research works printed but not linked: 19

  1. Park Y-L, 2011, Proc. IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, 4488
  2. Blanton S, 2002, Phys. Ther.
  3. Yamamoto S, 1993, J. Prosthet. Orthot.
  4. Geboers J F, 2000, Scand. J. Rehabil. Med.
  5. Lambrecht B G A, 2009, Proc. IEEE Int. Conf. on Robotics and Automation, 639
  6. Ferris D P, 2005, J. Appl. Biomech.
  7. Svensson W, 2008, Proc. IEEE Int. Conf. on Robotics Automation and Mechatronics, 301
  8. Galiana I, 2012, Proc. IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, 317
  9. Park Y-L, 2010, J. Micromech. Microeng., 20
  10. Park Y-L, 2012, Proc. IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, 1595
  11. Mengüc Y, 2013, Proc. IEEE Int. Conf. on Robotics and Automation, 5289
  12. Jien S, 2009, Proc. IEEE/ASME Int. Conf. on Advanced Intelligent Mechatronics, 1383
  13. Wolbrecht E T, 2006, Proc. 28th IEEE EMBS Annual Int. Conf., 2687
  14. Balasubramanian K, 2003, Proc. 22nd Int. Conf. North American Fuzzy Information Processing Society, 432
  15. Balasubramanian K, 2005, Proc. Annual Meeting North American Fuzzy Information Processing Society, 472
  16. Au S K, 2007, Proc. IEEE 10th Int. Conf. on Rehabilitation Robotics, 298
  17. Pérez Arancibia N O, 2004, Proc. ASME Int. Mechanical Engineering Congress and Exposition, 60256
  18. Rose J, 2006, Human Walking
  19. Fowler E G, 2001, Phys. Ther.

Cited by

See all 548

Metadata

Authors
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R.
Affiliations
  • Carnegie Mellon University (US)
  • BioSensics (United States) (US)
  • University of Southern California (US)
  • Harvard University (US)
  • Massachusetts Institute of Technology (US)
  • Boston Children's Hospital (US)
Corresponding author
Park, Yong-Lae
Venue
Bioinspiration & Biomimetics
Published
2014-01-16
Volume
9
Issue
1
Pages
016007
ISSN
  • 1748-3182 (ISSN-L)
  • 1748-3190
OpenAlex
W2144930761
Cited by
497
References
65
Citations by year
2026: 15 · 2025: 34 · 2024: 31 · 2023: 41 · 2022: 49 · 2021: 52 · 2020: 52 · 2019: 52 · 2018: 60 · 2017: 54 · 2016: 32 · 2015: 16 · 2014: 8
FWCI
19.03
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Bioinspiration & Biomimetics (publishedVersion)
  • PubMed (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
RIKEN
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
wearable robotic devices, pneumatic artificial muscles, soft robotics, biomimetic design, ankle orthoses, inversion and eversion, linear time-invariant controllers, system identification, ankle range of motion
MeSH terms
Biofeedback, Psychology, Computer Simulation, Equipment Design, Hardness, Humans, Models, Biological, Robotics, Therapy, Computer-Assisted, Muscle, Skeletal, Equipment Failure Analysis, Gait Disorders, Neurologic, Biomimetics, Foot Orthoses

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation. https://app.cochat.ai/papers/10.1088/1748-3182/9/1/016007
The paper
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014). Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation. Bioinspiration & Biomimetics. https://doi.org/10.1088/1748-3182/9/1/016007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.