The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Machine learning in point-of-care testing: innovations, challenges, and opportunities
Open accessAbstract
The landscape of diagnostic testing is undergoing a significant transformation, driven by the integration of artificial intelligence (AI) and machine learning (ML) into decentralized, rapid, and accessible sensor platforms for point-of-care testing (POCT). The COVID-19 pandemic has accelerated the shift from centralized laboratory testing but also catalyzed the development of next-generation POCT platforms that leverage ML to enhance the accuracy, sensitivity, and overall efficiency of point-of-care sensors. This Perspective explores how ML is being embedded into various POCT modalities, including lateral flow assays, vertical flow assays, nucleic acid amplification tests, and imaging-based sensors, illustrating their impact through different applications. We also discuss several challenges, such as regulatory hurdles, reliability, and privacy concerns, that must be overcome for the widespread adoption of ML-enhanced POCT in clinical settings and provide a comprehensive overview of the current state of ML-driven POCT technologies, highlighting their potential impact in the future of healthcare. Recent years have seen an increasing shift from centralized laboratory diagnostics to decentralized point-of-care testing, a shift which has the potential to increase health equity. Here the authors provide their perspective on how the integration of machine learning and artificial intelligence with point-of-care technologies can - and could - support this transition
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
Clinical-grade computational pathology using weakly supervised deep learning on whole slide images
Campanella, G., Hanna, M. G., Geneslaw, L., Miraflor, A., Werneck Krauss Silva, V., Busam, K. J., Brogi, E., Reuter, V. E., Klimstra, D. S., & Fuchs, T. J. (2019) · Nature Medicine · doi:10.1038/s41591-019-0508-1 · Cited by 2,799
A Survey on Explainable Artificial Intelligence (XAI): Toward Medical XAI
Tjoa, E., & Guan, C. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2020.3027314 · Cited by 2,524
Interpreting Black-Box Models: A Review on Explainable Artificial Intelligence
Hassija, V., Chamola, V., Mahapatra, A., Singal, A., Goel, D., Huang, K., Scardapane, S., Spinelli, I., Mahmud, M., & Hussain, A. (2024) · Cognitive Computation · doi:10.1007/s12559-023-10179-8 · Cited by 2,495 · cited 1×
“Toaddressthis challenge, thereis a growing emphasis on developing explainable AI (XAI) techniques 191,192 .”
The false hope of current approaches to explainable artificial intelligence in health care
Ghassemi, M., Oakden-Rayner, L., & Beam, A. L. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00208-9 · Cited by 1,724 · cited 1×
“Therefore, a thorough evaluation of ML models may be only available through careful and rigorous validation across multiple diverse populations and data centers, showcasing stable and accurate performance regardless of the tested patient group and institution 206 .”
Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002683 · Cited by 1,719 · cited 1×
“In a pneumonia detection study, CNN models trained to diagnose pneumoniausingradiographicimagescollectedinoneresearchcenter performed poorly when tested on data from another institution within the same country 187 .”
Benjamens, S., Dhunnoo, P., & Meskó, B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00324-0 · Cited by 1,215
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153 · cited 1×
“As another example, AI is being integrated into echocardiography, cardiac magnetic resonance imaging, and coronary computer tomography angiography, enabling automated segmentation, disease detection, and risk strati fi cation with performance comparable to human experts 143 – 145 .”
Transformer Interpretability Beyond Attention Visualization
Chefer, H., Gur, S., & Wolf, L. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.00084 · Cited by 903
The Clinician and Dataset Shift in Artificial Intelligence
Finlayson, S. G., Subbaswamy, A., Singh, K., Bowers, J., Kupke, A., Zittrain, J., Kohane, I. S., & Saria, S. (2021) · New England Journal of Medicine · doi:10.1056/nejmc2104626 · Cited by 855
Metadata
- Authors
- Han, G.-R., Goncharov, A., Eryilmaz, M., Ye, S., Palanisamy, B., Ghosh, R., Lisi, F., Rogers, E., Guzman, D., Yigci, D., Tasoglu, S., Di Carlo, D., Goda, K., McKendry, R. A., & Ozcan, A.
- Venue
- Nature Communications
- Published
- 2025-04-02
- Volume
- 16
- Issue
- 1
- Pages
- 3165-3165
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4409147844
- Cited by
- 239
- References
- 31
- FWCI
- 56.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Machine learning in point-of-care testing: innovations, challenges, and opportunities. https://app.cochat.ai/papers/10.1038/s41467-025-58527-6
- The paper
- Han, G.-R., Goncharov, A., Eryilmaz, M., Ye, S., Palanisamy, B., Ghosh, R., Lisi, F., Rogers, E., Guzman, D., Yigci, D., Tasoglu, S., Di Carlo, D., Goda, K., McKendry, R. A., & Ozcan, A. (2025). Machine learning in point-of-care testing: innovations, challenges, and opportunities. Nature Communications. https://doi.org/10.1038/s41467-025-58527-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.