Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Compliant plant wearables for localized microclimate and plant growth monitoring

Open access
Nassar, Joanna M., Khan, Sherjeel M., Villalva, Diego Rosas, Nour, Maha M., Almuslem, Amani S., Hussain, Muhammad M. · 2018 · npj Flexible Electronics

Abstract

The microclimate surrounding a plant has major effect on its health and photosynthesis process, where certain plants struggle in suboptimal environmental conditions and unbalanced levels of humidity and temperature. The ability to remotely track and correlate the effect of local environmental conditions on the healthy growth of plants can have great impact for increasing survival rate of plants and augmenting agriculture output. This necessitates the widespread distribution of lightweight sensory devices on the surface of each plant. Using flexible and biocompatible materials coupled with a smart compact design for a low power and lightweight system, we develop widely deployed, autonomous, and compliant wearables for plants. The demonstrated wearables integrate temperature, humidity and strain sensors, and can be intimately deployed on the soft surface of any plant to remotely and continuously evaluate optimal growth settings. This is enabled through simultaneous detection of environmental conditions while quantitatively tracking the growth rate (viz. elongation). Finally, we establish a nature-inspired origami-assembled 3D-printed “PlantCopter”, used as a launching platform for our plant wearable to enable widespread microclimate monitoring in large fields.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41528-018-0039-8

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 251

Metadata

Authors
Nassar, J. M., Khan, S. M., Villalva, D. R., Nour, M. M., Almuslem, A. S., & Hussain, M. M.
Venue
npj Flexible Electronics
Published
2018-09-10
Volume
2
Issue
1
ISSN
2397-4621 (ISSN-L)
OpenAlex
W2885555450
Cited by
251
References
2
FWCI
4.72
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compliant plant wearables for localized microclimate and plant growth monitoring. https://app.cochat.ai/papers/10.1038/s41528-018-0039-8
The paper
Nassar, J. M., Khan, S. M., Villalva, D. R., Nour, M. M., Almuslem, A. S., & Hussain, M. M. (2018). Compliant plant wearables for localized microclimate and plant growth monitoring. npj Flexible Electronics. https://doi.org/10.1038/s41528-018-0039-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.