Polymeric foams for flexible and highly sensitive low-pressure capacitive sensors
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Flexible low-pressure sensors ( <10 kPa) are required in areas as diverse as blood-pressure monitoring, human–computer interactions, robotics, and object detection. For applications, it is essential that these sensors combine flexibility, high sensitivity, robustness, and low production costs. Previous works involve surface micro-patterning, electronic amplification (OFET), and hydrogels. However, these solutions are limited as they involve complex processes, large bias voltages, large energy consumption, or are sensitive to evaporation. Here, we report a major advance to solve the challenge of scalable, efficient and robust e-skin. We present an unconventional capacitive sensor based on composite foam materials filled with conductive carbon black particles. Owing to the elastic buckling of the foam pores, the sensitivity exceeds 35 kPa−1 for pressure <0.2 kPa. These performances are one order of magnitude higher than the ones previously reported. These materials are low-cost, easy to prepare, and display high capacitance values, which are easy to measure using low-cost electronics. These materials pave the road for the implementation of e-skin in commercialized applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Cellular Solids: Structure and Properties
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326 · Cited by 5,512
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · cited 4×
“Mannsfeld et al.(7) microstructured a polydimethylsiloxane (PDMS) film to subtly change the permittivity of piezo-capacitive sensors.”
BackgroundInfluentialTrung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042 · cited 3×
“This is a standard test.(14,17) The sensitive material was sandwiched between two compliant electrodes by depositing conductive flexible carbon tape on the top and the bottom of the materials surfaces as illustrated in Fig.”
MethodInfluentialFiber‐Based Wearable Electronics: A Review of Materials, Fabrication, Devices, and Applications
Zeng, W., Shu, L., Li, Q., Chen, S., Wang, F., & Tao, X. (2014) · Advanced Materials · doi:10.1002/adma.201400633 · Cited by 2,019
A bioinspired flexible organic artificial afferent nerve
Kim, Y., Chortos, A., Xu, W., Liu, Y., Oh, J. Y., Son, D., Kang, J., Foudeh, A. M., Zhu, C., Lee, Y., et al. (2018) · Science · doi:10.1126/science.aao0098 · Cited by 1,466
Wang, X., Gu, Y., Xiong, Z., Cui, Z., & Zhang, T. (2014) · Advanced Materials · doi:10.1002/adma.201304248 · Cited by 1,398
Wearable multifunctional sensors using printed stretchable conductors made of silver nanowires
Yao, S., & Zhu, Y. (2014) · Nanoscale · doi:10.1039/c3nr05496a · Cited by 1,028 · cited 1×
“The theoretical value of gauge factor for incompressible materials due to geometrical change and assuming a constant dielectric constant is 1 (refs.(15,16)).”
Background
Cited by
Bai, N., Wang, L., Wang, Q., Deng, J., Wang, Y., Lu, P., Huang, J., Li, G., Zhang, Y., Yang, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-14054-9 · Cited by 810
Flexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Recent Progress on Flexible Capacitive Pressure Sensors: From Design and Materials to Applications
Mishra, R. B., El‐Atab, N., Hussain, A. M., & Hussain, M. M. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202001023 · Cited by 433
Hwang, J., Kim, Y., Yang, H., & Oh, J. H. (2021) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2021.108607 · Cited by 385
Ha, K., Zhang, W., Jang, H., Kang, S., Wang, L., Tan, P., Hwang, H., & Lu, N. (2021) · Advanced Materials · doi:10.1002/adma.202103320 · Cited by 354
Recent Progress in Flexible Pressure Sensors Based Electronic Skin
Pierre Claver, U., & Zhao, G. (2021) · Advanced Engineering Materials · doi:10.1002/adem.202001187 · Cited by 291
Research progress of flexible capacitive pressure sensor for sensitivity enhancement approaches
Li, R., Zhou, Q., Bi, Y., Cao, S., Xia, X., Yang, A., Li, S., & Xiao, X. (2021) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112425 · Cited by 276
Thermally drawn advanced functional fibers: New frontier of flexible electronics
Yan, W., Dong, C., Xiang, Y., Jiang, S., Leber, A., Loke, G., Xu, W., Hou, C., Zhou, S., Chen, M., et al. (2020) · Materials Today · doi:10.1016/j.mattod.2019.11.006 · Cited by 263
Masihi, S., Panahi, M., Maddipatla, D., Hanson, A. J., Bose, A. K., Hajian, S., Palaniappan, V., Narakathu, B. B., Bazuin, B. J., & Atashbar, M. Z. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02122 · Cited by 254
Yang, J., Tang, D., Ao, J., Ghosh, T., Neumann, T. V., Zhang, D., Piskarev, Y., Yu, T., Truong, V. K., Xie, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202002611 · Cited by 233
Chhetry, A., Sharma, S., Yoon, H., Ko, S., & Park, J. Y. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910020 · Cited by 228
Zhou, Q., Ji, B., Wei, Y., Hu, B., Gao, Y., Xu, Q., Zhou, J., & Zhou, B. (2019) · Journal of Materials Chemistry A · doi:10.1039/c9ta10489e · Cited by 194
Tay, R. Y., Li, H., Lin, J., Wang, H., Lim, J. S. K., Chen, S., Leong, W. L., Tsang, S. H., & Teo, E. H. T. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909604 · Cited by 175
Advanced Flexible Sensing Technologies for Soft Robots
Qu, J., Cui, G., Li, Z., Fang, S., Zhang, X., Liu, A., Han, M., Liu, H., Wang, X., & Wang, X. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202401311 · Cited by 175
Vu, C. C., & Kim, J. (2020) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2020.112029 · Cited by 109
Metadata
- Authors
- Pruvost, M., Smit, W. J., Monteux, C., Poulin, P., & Colin, A.
- Venue
- npj Flexible Electronics
- Published
- 2019-04-04
- Volume
- 3
- Issue
- 1
- ISSN
- 2397-4621 (ISSN-L)
- OpenAlex
- W2925764292
- Cited by
- 204
- References
- 23
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.