The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
A bio-inspired cilia array as the dielectric layer for flexible capacitive pressure sensors with high sensitivity and a broad detection range
Abstract
A cilia array via a magnetic field was proposed as the dielectric layer for flexible capacitive sensors with high sensitivity and a broad detection range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Recent Progress in Electronic Skin
Wang, X., Dong, L., Zhang, H., Yu, R., Pan, C., & Wang, Z. L. (2015) · Advanced Science · doi:10.1002/advs.201500169 · Cited by 976
Joo, Y., Byun, J., Seong, N., Ha, J., Kim, H., Kim, S., Kim, T., Im, H., Kim, D., & Hong, Y. (2015) · Nanoscale · doi:10.1039/c5nr00313j · Cited by 378
Wearable and flexible sensors for user-interactive health-monitoring devices
Ha, M., Lim, S., & Ko, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb01063c · Cited by 352
Wang, J., Jiu, J., Nogi, M., Sugahara, T., Nagao, S., Koga, H., He, P., & Suganuma, K. (2015) · Nanoscale · doi:10.1039/c4nr06494a · Cited by 293
Cited by
Flexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Ha, K., Zhang, W., Jang, H., Kang, S., Wang, L., Tan, P., Hwang, H., & Lu, N. (2021) · Advanced Materials · doi:10.1002/adma.202103320 · Cited by 354
Guo, Y., Wei, X., Gao, S., Yue, W., Li, Y., & Shen, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104288 · Cited by 279
Flexible capacitive pressure sensors for wearable electronics
Wang, H., Li, Z., Liu, Z., Fu, J., Shan, T., Yang, X., Lei, Q., Yang, Y., & Li, D. (2022) · Journal of Materials Chemistry C · doi:10.1039/d1tc05304c · Cited by 263
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Metadata
- Authors
- Zhou, Q., Ji, B., Wei, Y., Hu, B., Gao, Y., Xu, Q., Zhou, J., & Zhou, B.
- Venue
- Journal of Materials Chemistry A
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2019
- Volume
- 7
- Issue
- 48
- Pages
- 27334-27346
- ISSN
- 2050-7488 (ISSN-L)
- 2050-7496
- OpenAlex
- W2991055446
- Cited by
- 194
- References
- 7
- FWCI
- 7.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A bio-inspired cilia array as the dielectric layer for flexible capacitive pressure sensors with high sensitivity and a broad detection range. https://app.cochat.ai/papers/10.1039/c9ta10489e
- The paper
- Zhou, Q., Ji, B., Wei, Y., Hu, B., Gao, Y., Xu, Q., Zhou, J., & Zhou, B. (2019). A bio-inspired cilia array as the dielectric layer for flexible capacitive pressure sensors with high sensitivity and a broad detection range. Journal of Materials Chemistry A. https://doi.org/10.1039/c9ta10489e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.