Data centre water consumption
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
The information communication technology sector will experience huge growth over the coming years, with 29.3 billion devices expected online by 2030, up from 18.4 billion in 2018. To reliably support the online services used by these billions of users, data centres have been built around the world to provide the millions of servers they contain with access to power, cooling and internet connectivity. Whilst the energy consumption of these facilities regularly receives mainstream and academic coverage, analysis of their water consumption is scarce. Data centres consume water directly for cooling, in some cases 57% sourced from potable water, and indirectly through the water requirements of non-renewable electricity generation. Although in the USA, data centre water consumption (1.7 billion litres/day) is small compared to total water consumption (1218 billion litres/day), there are issues of transparency with less than a third of data centre operators measuring water consumption. This paper examines the water consumption of data centres, the measurement of that consumption, highlights the lack of data available to assess water efficiency, and discusses and where the industry is going in attempts to reduce future consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
(2005) · Proceedings of the Water Environment Federation · doi:10.2175/193864705783867675 · Cited by 6,678
Recalibrating global data center energy-use estimates
Masanet, E., Shehabi, A., Lei, N., Smith, S., & Koomey, J. (2020) · Science · doi:10.1126/science.aba3758 · Cited by 1,545
On Global Electricity Usage of Communication Technology: Trends to 2030
Andrae, A., & Edler, T. (2015) · Challenges · doi:10.3390/challe6010117 · Cited by 1,334
United States Data Center Energy Usage Report
Lawrence Berkeley National Laboratory (LBNL), B., Shehabi, A., USDOE, Smith, S., Sartor, D., Brown, R., Herrlin, M., Koomey, J., Masanet, E., Horner, N., et al. (2016) · doi:10.2172/1372902 · Cited by 1,040
OECD Environmental Outlook to 2050: The Consequences of Inaction
OECD (2012) · OECD Environmental Outlook · doi:10.1787/9789264122246-en · Cited by 825
Ebrahimi, K., Jones, G. F., & Fleischer, A. S. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.12.007 · Cited by 779
Estimated use of water in the United States in 2015
Dieter, C. A., Maupin, M. A., Caldwell, R. R., Harris, M. A., Ivahnenko, T. I., Lovelace, J. K., Barber, N. L., & Linsey, K. S. (2018) · Circular · doi:10.3133/cir1441 · Cited by 755
Macknick, J., Newmark, R., Heath, G., & Hallett, K. C. (2012) · Environmental Research Letters · doi:10.1088/1748-9326/7/4/045802 · Cited by 631
Cooling Systems in Data Centers: State of Art and Emerging Technologies
Capozzoli, A., & Primiceri, G. (2015) · Energy Procedia · doi:10.1016/j.egypro.2015.12.168 · Cited by 238
Machine Learning Applications for Data Center Optimization
Gao, J. (2014) · Cited by 222
Consumptive Water Use for U.S. Power Production
Torcellini, P., Long, N., & Judkoff, R. (2003) · doi:10.2172/15005918 · Cited by 212
Pan, S.-Y., Snyder, S. W., Packman, A. I., Lin, Y. J., & Chiang, P.-C. (2018) · Water-Energy Nexus · doi:10.1016/j.wen.2018.04.002 · Cited by 193
Data center growth in the United States: decoupling the demand for services from electricity use
Shehabi, A., Smith, S. J., Masanet, E., & Koomey, J. (2018) · Environmental Research Letters · doi:10.1088/1748-9326/aaec9c · Cited by 189
A case study and critical assessment in calculating power usage effectiveness for a data centre
Brady, G. A., Kapur, N., Summers, J. L., & Thompson, H. M. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.07.035 · Cited by 127
Cooling Energy-Hungry Data Centers
Meijer, G. I. (2010) · Science · doi:10.1126/science.1182769 · Cited by 126
Regional water consumption for hydro and thermal electricity generation in the United States
Lee, U., Han, J., Elgowainy, A., & Wang, M. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.025 · Cited by 105
Influence of cooling architecture on data center power consumption
Moazamigoodarzi, H., Tsai, P. J., Pal, S., Ghosh, S., & Puri, I. K. (2019) · Energy · doi:10.1016/j.energy.2019.06.140 · Cited by 90
Hiding greenhouse gas emissions in the cloud
Mytton, D. (2020) · Nature Climate Change · doi:10.1038/s41558-020-0837-6 · Cited by 65
Self-citationThe Drivers of Corporate Water Disclosure in Enhancing Information Transparency
Yu, H., Kuo, L., & Ma, B. (2020) · Sustainability · doi:10.3390/su12010385 · Cited by 55
Mytton, D. (2020) · Journal of Cloud Computing Advances Systems and Applications · doi:10.1186/s13677-020-00185-8 · Cited by 46
Self-citationAn analysis of the power usage effectiveness metric in data centers
Rădulescu, C. Z., Radulescu, D. M., & Sipică, A. (2017) · doi:10.1109/iseee.2017.8170650 · Cited by 33
Water efficiency management in datacenters: Metrics and methodology
Sharma, R. K., Shah, A. J., Bash, C. E., Christian, T., & Patel, C. D. (2009) · IEEE International Symposium on Sustainable Systems and Technology · doi:10.1109/issst.2009.5156773 · Cited by 24
Peck, J. J., & Smith, A. D. (2016) · Energy Reports · doi:10.1016/j.egyr.2016.11.002 · Cited by 14
From click to playback: a dataset to study the response time of mobile YouTube
Loh, F., Wamser, F., Moldovan, C., Zeidler, B., Hoßfeld, T., Tsilimantos, D., & Valentin, S. (2019) · ACM Multimedia Systems Conference (MMSys) · doi:10.1145/3304109.3325819 · Cited by 8
van de Voort, T., Zavřel, V., Torrens, J. I., & Hensen, J. J. (2017) · TU/e Research Portal · Cited by 5
Cited by
Taxonomy of Risks posed by Language Models
Weidinger, L., Uesato, J., Rauh, M., Griffin, C., Huang, P.-S., Mellor, J., Glaese, A., Cheng, M., Balle, B., Kasirzadeh, A., et al. (2022) · 2022 ACM Conference on Fairness Accountability and Transparency · doi:10.1145/3531146.3533088 · Cited by 764
Ethical and social risks of harm from Language Models
Weidinger, L., Mellor, J., Rauh, M., Griffin, C., Uesato, J., Huang, P.-S., Cheng, M., Glaese, M., Balle, B., Kasirzadeh, A., et al. (2021) · arXiv · doi:10.48550/arxiv.2112.04359 · Cited by 477
“Problem Large-scale machine learning models, including LMs, have the potential to create significant environmental costs via their energy demands, the associated carbon emissions for training and operating the models, and the demand for fresh water to cool the data centres where computations are run (Mytton, 2021; Pat…”
BackgroundMannuru, N. R., Shahriar, S., Teel, Z. A., Wang, T., Lund, B. D., Tijani, S., Pohboon, C. O., Agbaji, D., Alhassan, J., Galley, J., et al. (2025) · Information Development · doi:10.1177/02666669231200628 · Cited by 314
Xiao, T., Nerini, F. F., Matthews, H. D., Tavoni, M., & You, F. (2025) · Nature Sustainability · doi:10.1038/s41893-025-01681-y · Cited by 121
“Centralized installation in water-stressed regions may perturb local water balance and threaten supply for millions 17,18 .”
The water use of data center workloads: A review and assessment of key determinants
Lei, N., Lu, J., Shehabi, A., & Masanet, E. (2025) · Resources, Conservation and Recycling · doi:10.1016/j.resconrec.2025.108310 · Cited by 79
Metadata
- Authors
- Mytton, D.
- Venue
- npj Clean Water
- Published
- 2021-02-15
- Volume
- 4
- Issue
- 1
- ISSN
- 2059-7037 (ISSN-L)
- OpenAlex
- W3132005749
- Cited by
- 225
- References
- 25
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.