A carbon nanotube reporter of microRNA hybridization events in vivo
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
MicroRNAs and other small oligonucleotides in biofluids are promising disease biomarkers, yet conventional assays require complex processing steps that are unsuitable for point-of-care testing or for implantable or wearable sensors. Single-walled carbon nanotubes are an ideal material for implantable sensors, owing to their emission in the near-infrared spectral region, photostability and exquisite sensitivity. Here, we report an engineered carbon-nanotube-based sensor capable of real-time optical quantification of hybridization events of microRNA and other oligonucleotides. The mechanism of the sensor arises from competitive effects between displacement of both oligonucleotide charge groups and water from the nanotube surface, which result in a solvatochromism-like response. The sensor, which allows for detection via single-molecule sensor elements and for multiplexing by using multiple nanotube chiralities, can monitor toehold-based strand-displacement events, which reverse the sensor response and regenerate the sensor complex. We also show that the sensor functions in whole urine and serum, and can non-invasively measure DNA and microRNA after implantation in live mice. A carbon nanotube sensor enables real-time optical quantification of hybridization events of microRNA and other oligonucleotides in vivo and in whole urine and serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VMD: visual molecular dynamics
Humphrey, W., Dalke, A., & Schulten, K. (1996) · Journal of Molecular Graphics · doi:10.1016/0263-7855(96)00018-5 · Cited by 66,952
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
A smooth particle mesh Ewald method
Essmann, U., Perera, L., Berkowitz, M. L., Darden, T., Lee, H., & Pedersen, L. G. (1995) · The Journal of Chemical Physics · doi:10.1063/1.470117 · Cited by 22,514
GROMACS 4: Algorithms for Highly Efficient, Load-Balanced, and Scalable Molecular Simulation
Hess, B., Kutzner, C., van der Spoel, D., & Lindahl, E. (2008) · Journal of Chemical Theory and Computation · doi:10.1021/ct700301q · Cited by 15,908
GROMACS: A message-passing parallel molecular dynamics implementation
Berendsen, H. J. C., van der Spoel, D., & van Drunen, R. (1995) · Computer Physics Communications · doi:10.1016/0010-4655(95)00042-e · Cited by 10,405
Circulating microRNAs as stable blood-based markers for cancer detection
Mitchell, P. S., Parkin, R. K., Kroh, E. M., Fritz, B. R., Wyman, S. K., Pogosova-Agadjanyan, E. L., Peterson, A., Noteboom, J., O'Briant, K. C., Allen, A., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804549105 · Cited by 7,969
Real-time quantification of microRNAs by stem-loop RT-PCR
Chen, C. (2005) · Nucleic Acids Research · doi:10.1093/nar/gni178 · Cited by 4,952
Replica-exchange molecular dynamics method for protein folding
Sugita, Y., & Okamoto, Y. (1999) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)01123-9 · Cited by 4,514
MDAnalysis: A toolkit for the analysis of molecular dynamics simulations
Michaud‐Agrawal, N., Denning, E. J., Woolf, T. B., & Beckstein, O. (2011) · Journal of Computational Chemistry · doi:10.1002/jcc.21787 · Cited by 4,486
Band Gap Fluorescence from Individual Single-Walled Carbon Nanotubes
O'Connell, M. J., Bachilo, S. M., Huffman, C. B., Moore, V. C., Strano, M. S., Haroz, E. H., Rialon, K. L., Boul, P. J., Noon, W. H., Kittrell, C., et al. (2002) · Science · doi:10.1126/science.1072631 · Cited by 3,879
Cited by
Optical nano-agents in the second near-infrared window for biomedical applications
Cai, Y., Wei, Z., Song, C., Tang, C., Han, W., & Dong, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00494c · Cited by 603
Photoluminescent Nanoparticles for Chemical and Biological Analysis and Imaging
Algar, W. R., Massey, M., Rees, K., Higgins, R., Krause, K. D., Darwish, G. H., Peveler, W. J., Xiao, Z., Tsai, H.-Y., Gupta, R., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01176 · Cited by 356
Carbon nanocarriers deliver siRNA to intact plant cells for efficient gene knockdown
Demirer, G. S., Zhang, H., Goh, N. S., Pinals, R. L., Chang, R., & Landry, M. P. (2020) · Science Advances · doi:10.1126/sciadv.aaz0495 · Cited by 295
Biosensing with Fluorescent Carbon Nanotubes
Ackermann, J., Metternich, J. T., Herbertz, S., & Kruss, S. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202112372 · Cited by 280
Monitoring Plant Health with Near-Infrared Fluorescent H2O2 Nanosensors
Wu, H., Nißler, R., Morris, V., Herrmann, N., Hu, P., Jeon, S.-J., Kruss, S., & Giraldo, J. P. (2020) · Nano Letters · doi:10.1021/acs.nanolett.9b05159 · Cited by 271
Carbon Nanomaterial Fluorescent Probes and Their Biological Applications
Krasley, A. T., Li, E., Galeana, J. M., Bulumulla, C., Beyene, A. G., & Demirer, G. S. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00581 · Cited by 242
Noninvasive ovarian cancer biomarker detection via an optical nanosensor implant
Williams, R. M., Lee, C., Galassi, T. V., Harvey, J. D., Leicher, R., Sirenko, M., Dorso, M. A., Shah, J., Olvera, N., Dao, F., et al. (2018) · Science Advances · doi:10.1126/sciadv.aaq1090 · Cited by 183
Self-citationWireless, battery-free optoelectronic systems as subdermal implants for local tissue oximetry
Zhang, H., Gutruf, P., Meacham, K., Montana, M. C., Zhao, X., Chiarelli, A. M., Vázquez-Guardado, A., Norris, A., Lu, L., Guo, Q., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw0873 · Cited by 173
Multiplexed imaging for diagnosis and therapy
Heinzmann, K., Carter, L. M., Lewis, J. S., & Aboagye, E. O. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0131-8 · Cited by 168
A Carbon Nanotube Optical Reporter Maps Endolysosomal Lipid Flux
Jena, P. V., Roxbury, D., Galassi, T. V., Akkari, L., Horoszko, C. P., Iaea, D. B., Budhathoki-Uprety, J., Pipalia, N., Haka, A. S., Harvey, J. D., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b04743 · Cited by 125
Self-citationOptical Voltammetry of Polymer-Encapsulated Single-Walled Carbon Nanotubes
Horoszko, C. P., Jena, P. V., Roxbury, D., Rotkin, S. V., & Heller, D. A. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b07626 · Cited by 9
Self-citation
Metadata
- Authors
- Harvey, J. D., Jena, P. V., Baker, H. A., Zerze, G. H., Williams, R. M., Galassi, T. V., Roxbury, D., Mittal, J., & Heller, D. A.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-03-13
- Volume
- 1
- Issue
- 4
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2595181440
- Cited by
- 203
- References
- 67
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.