Light-sheet microscopy for slide-free non-destructive pathology of large clinical specimens
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
For the 1.7 million patients per year in the US who receive a new cancer diagnosis, treatment decisions are largely based on histopathological specimen examinations. Unfortunately, the gold standard of slide-based microscopic pathology suffers from high inter-observer variability and limited prognostic value due to sampling limitations and the inability to visualize tissue structures and molecular targets in their native 3D context. Here, we show that an open-top light-sheet microscope optimized for non-destructive slide-free pathology of clinical specimens enables the rapid imaging of intact tissues at high resolution over large 2D and 3D fields of view, with the same level of detail as traditional pathology. We demonstrate the utility of this technology for various applications: wide-area surface microscopy to triage surgical specimens (with ~200 μm surface irregularities), rapid intraoperative assessment of tumour-margin surfaces (12.5 s cm−2), and volumetric assessment of optically cleared core-needle biopsies (1 mm in diameter, 2 cm in length). Light-sheet microscopy can be a versatile tool for both rapid surface microscopy and deep volumetric microscopy of human specimens. A light-sheet microscope images large surgical and biopsy specimens non-destructively over large fields of view in two and three dimensions, with the same level of detail as traditional slide-based histopathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Globally optimal stitching of tiled 3D microscopic image acquisitions
Preibisch, S., Saalfeld, S., & Tomancak, P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp184 · Cited by 2,452
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Structural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008 · cited 1×
“4a) was optically cleared (overnight procedure) using a protocol based on the CLARITY method [42], fluorescently stained with DRAQ5 and eosin (D&E), and imaged using the open-top light-sheet microscope.”
Reconstruction of Zebrafish Early Embryonic Development by Scanned Light Sheet Microscopy
Keller, P. J., Schmidt, A. D., Wittbrodt, J., & Stelzer, E. H. K. (2008) · Science · doi:10.1126/science.1162493 · Cited by 1,560
Ultramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain
Dodt, H.-U., Leischner, U., Schierloh, A., Jährling, N., Mauch, C. P., Deininger, K., Deussing, J. M., Eder, M., Zieglgänsberger, W., & Becker, K. (2007) · Nature Methods · doi:10.1038/nmeth1036 · Cited by 1,238
Revision of the American Joint Committee on Cancer Staging System for Breast Cancer
Singletary, S. E., Allred, C., Ashley, P., Bassett, L. W., Berry, D., Bland, K. I., Borgen, P. I., Clark, G., Edge, S. B., Hayes, D. F., et al. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.02.026 · Cited by 1,173
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Stripe and ring artifact removal with combined wavelet—Fourier filtering
Münch, B., Trtik, P., Marone, F., & Stampanoni, M. (2009) · Optics Express · doi:10.1364/oe.17.008567 · Cited by 681
A guide to light-sheet fluorescence microscopy for multiscale imaging
Power, R. M., & Huisken, J. (2017) · Nature Methods · doi:10.1038/nmeth.4224 · Cited by 636
Moran, M. S., Schnitt, S. J., Giuliano, A. E., Harris, J. R., Khan, S. A., Horton, J., Klimberg, S., Chavez-MacGregor, M., Freedman, G., Houssami, N., et al. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-014-3481-4 · Cited by 612
Orringer, D. A., Pandian, B., Niknafs, Y. S., Hollon, T. C., Boyle, J., Lewis, S., Garrard, M., Hervey-Jumper, S. L., Garton, H. J. L., Maher, C. O., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0027 · Cited by 568
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Tomer, R., Khairy, K., Amat, F., & Keller, P. J. (2012) · Nature Methods · doi:10.1038/nmeth.2062 · Cited by 545
Moran, M. S., Schnitt, S. J., Giuliano, A. E., Harris, J. R., Khan, S. A., Horton, J., Klimberg, S., Chavez-MacGregor, M., Freedman, G., Houssami, N., et al. (2014) · Journal of Clinical Oncology · doi:10.1200/jco.2013.53.3935 · Cited by 451
Nanoscale imaging of RNA with expansion microscopy
Chen, F., Wassie, A. T., Cote, A. J., Sinha, A., Alon, S., Asano, S., Daugharthy, E. R., Chang, J.-B., Marblestone, A., Church, G. M., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3899 · Cited by 404
Live-cell 3D super-resolution imaging in thick biological samples
Cella Zanacchi, F., Lavagnino, Z., Perrone Donnorso, M., Del Bue, A., Furia, L., Faretta, M., & Diaspro, A. (2011) · Nature Methods · doi:10.1038/nmeth.1744 · Cited by 385
OpenSPIM: an open-access light-sheet microscopy platform
Pitrone, P. G., Schindelin, J., Stuyvenberg, L., Preibisch, S., Weber, M., Eliceiri, K. W., Huisken, J., & Tomancak, P. (2013) · Nature Methods · doi:10.1038/nmeth.2507 · Cited by 360
Optical sectioning microscopy with planar or structured illumination
Mertz, J. (2011) · Nature Methods · doi:10.1038/nmeth.1709 · Cited by 347
Siedentopf, H., & Zsigmondy, R. (1902) · Annalen der Physik · doi:10.1002/andp.19023150102 · Cited by 321
Moffitt, J. R., Hao, J., Bambah-Mukku, D., Lu, T., Dulac, C., & Zhuang, X. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1617699113 · Cited by 308
Wu, Y., Ghitani, A., Christensen, R., Santella, A., Du, Z., Rondeau, G., Bao, Z., Colón-Ramos, D., & Shroff, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108494108 · Cited by 304
Meyer, J. S., Alvarez, C., Milikowski, C., Olson, N., Russo, I., Russo, J., Glass, A., Zehnbauer, B. A., Lister, K., & Parwaresch, R. (2005) · Modern Pathology · doi:10.1038/modpathol.3800388 · Cited by 262
Stain-free histopathology by programmable supercontinuum pulses
Tu, H., Liu, Y., Turchinovich, D., Marjanovic, M., Lyngsø, J. K., Lægsgaard, J., Chaney, E. J., Zhao, Y., You, S., Wilson, W. L., et al. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.94 · Cited by 233
Dual-view plane illumination microscopy for rapid and spatially isotropic imaging
Kumar, A., Wu, Y., Christensen, R., Chandris, P., Gandler, W., McCreedy, E., Bokinsky, A., Colón-Ramos, D. A., Bao, Z., McAuliffe, M., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.172 · Cited by 231
Assessment of breast pathologies using nonlinear microscopy
Tao, Y. K., Shen, D., Sheikine, Y., Ahsen, O. O., Wang, H. H., Schmolze, D. B., Johnson, N. B., Brooker, J. S., Cable, A. E., Connolly, J. L., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1416955111 · Cited by 211
Guide to light-sheet microscopy for adventurous biologists
Reynaud, E. G., Peychl, J., Huisken, J., & Tomancak, P. (2015) · Nature Methods · doi:10.1038/nmeth.3222 · Cited by 209
Positive Margins: The Challenge Continues for Breast Surgeons
Jacobs, L. (2008) · Annals of Surgical Oncology · doi:10.1245/s10434-007-9766-0 · Cited by 194
Any Way You Slice It—A Comparison of Confocal Microscopy Techniques
Jonkman, J., & Brown, C. M. (2015) · Journal of Biomolecular Techniques : JBT · doi:10.7171/jbt.15-2602-003 · Cited by 194
Inverted light-sheet microscope for imaging mouse pre-implantation development
Strnad, P., Gunther, S., Reichmann, J., Krzic, U., Balazs, B., de Medeiros, G., Norlin, N., Hiiragi, T., Hufnagel, L., & Ellenberg, J. (2016) · Nature Methods · doi:10.1038/nmeth.3690 · Cited by 182
Assayag, O. (2013) · TCRT Express · doi:10.7785/tcrtexpress.2013.600254 · Cited by 168
Model-Based 2.5-D Deconvolution for Extended Depth of Field in Brightfield Microscopy
Aguet, F., Ville, D. V. D., & Unser, M. A. (2008) · IEEE Transactions on Image Processing · doi:10.1109/tip.2008.924393 · Cited by 159
Confocal mosaicing microscopy in Mohs skin excisions: feasibility of rapid surgical pathology
Gareau, D. S., Li, Y., Huang, B., Eastman, Z., Nehal, K. S., & Rajadhyaksha, M. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2981828 · Cited by 158
Toward Routine Use of 3D Histopathology as a Research Tool
Roberts, N., Magee, D., Song, Y., Brabazon, K., Shires, M., Crellin, D., Orsi, N. M., Quirke, R., Quirke, P., & Treanor, D. (2012) · The American Journal of Pathology · doi:10.1016/j.ajpath.2012.01.033 · Cited by 153
Virtual Hematoxylin and Eosin Transillumination Microscopy Using Epi-Fluorescence Imaging
Giacomelli, M. G., Husvogt, L., Vardeh, H. G., Faulkner-Jones, B. E., Joachim Hornegger, A., Connolly, J. L., & Fujimoto, J. G. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159337 · Cited by 120
Open-top selective plane illumination microscope for conventionally mounted specimens
McGorty, R., Liu, H., Kamiyama, D., Dong, Z., Guo, S., & Huang, B. (2015) · Optics Express · doi:10.1364/oe.23.016142 · Cited by 113
McKenney, J. K., Simko, J. P., Bonham, M. J., True, L. D., Troyer, D. A., Hawley, S. J., Newcomb, L. F., Fazli, L., Kunju, L. P., Nicolas, M. M., et al. (2011) · The Journal of Urology · doi:10.1016/j.juro.2011.03.115 · Cited by 107
Self-citationFu, Q., Martin, B. L., Matus, D. Q., & Gao, L. (2016) · Nature Communications · doi:10.1038/ncomms11088 · Cited by 106
Confocal multiview light-sheet microscopy
de Medeiros, G., Norlin, N., Gunther, S., Albert, M., Panavaite, L., Fiúza, U.-M., Peri, F., Hiiragi, T., Kržič, U., & Hufnagel, L. (2015) · Nature Communications · doi:10.1038/ncomms9881 · Cited by 101
An Abbreviated Standard Procedure for Accurate Tumor Volume Estimation in Prostate Cancer
Schmid, H., & McNeal, J. E. (1992) · The American Journal of Surgical Pathology · doi:10.1097/00000478-199202000-00012 · Cited by 97
Three‐dimensional microscopic analysis of clinical prostate specimens
van Royen, M. E., Verhoef, E. I., Kweldam, C. F., van Cappellen, W. A., Kremers, G., Houtsmuller, A. B., & van Leenders, G. J. L. H. (2016) · Histopathology · doi:10.1111/his.13022 · Cited by 93
Elfer, K. N., Sholl, A. B., Wang, M., Tulman, D. B., Mandava, S. H., Lee, B. R., & Brown, J. Q. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165530 · Cited by 79
Multiphoton microscopy with clearing for three dimensional histology of kidney biopsies
Olson, E. M., Levene, M. J., & TORRES, R. A. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003089 · Cited by 76
Wang, M., Kimbrell, H. Z., Sholl, A. B., Tulman, D. B., Elfer, K. N., Schlichenmeyer, T. C., Lee, B. R., Lacey, M. R., & Brown, J. Q. (2015) · Cancer Research · doi:10.1158/0008-5472.can-14-3806 · Cited by 75
Diagnosis of “Poorly Formed Glands” Gleason Pattern 4 Prostatic Adenocarcinoma on Needle Biopsy
Zhou, M., Li, J., Liang Cheng, C., Egevad, L., Deng, F.-M., Kunju, L. P., Magi‐Galluzzi, C., Melamed, J., Mehra, R., Mendrinos, S. E., et al. (2015) · The American Journal of Surgical Pathology · doi:10.1097/pas.0000000000000457 · Cited by 74
Shah, R. B., Li, J., Cheng, L., Egevad, L., Deng, F.-M., Fine, S. W., Kunju, L. P., Melamed, J., Mehra, R., Osunkoya, A. O., et al. (2015) · The American Journal of Surgical Pathology · doi:10.1097/pas.0000000000000442 · Cited by 50
Imaging subcellular dynamics with fast and light-efficient volumetrically parallelized microscopy
Dean, K. M., Roudot, P., Welf, E. S., Pohlkamp, T., Garrelts, G., Herz, J., & Fiolka, R. P. (2017) · Optica · doi:10.1364/optica.4.000263 · Cited by 43
The Role of Margin Status and Reexcision in Local Recurrence Following Breast Conservation Surgery
Adams, B. J., Zoon, C. K., Stevenson, C. E., Chitnavis, P. V., Wolfe, L. G., & Bear, H. D. (2013) · Annals of Surgical Oncology · doi:10.1245/s10434-012-2831-3 · Cited by 39
Assessing the imaging performance of light sheet microscopies in highly scattering tissues
Glaser, A. K., Wang, Y., & Liu, J. T. C. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000454 · Cited by 26
Self-citation
Cited by
Artificial intelligence in digital pathology — new tools for diagnosis and precision oncology
Bera, K., Schalper, K. A., Rimm, D. L., Velcheti, V., & Madabhushi, A. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0252-y · Cited by 1,698
Virtual histological staining of unlabelled tissue-autofluorescence images via deep learning
Rivenson, Y., Wang, H., Wei, Z., de Haan, K., Zhang, Y., Wu, Y., Günaydın, H., Zuckerman, J. E., Chong, T., Sisk, A. E., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0362-y · Cited by 640
Tissue clearing and its applications in neuroscience
Ueda, H. R., Ertürk, A., Chung, K., Gradinaru, V., Chédotal, A., Tomancak, P., & Keller, P. J. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0250-1 · Cited by 609
Protection of tissue physicochemical properties using polyfunctional crosslinkers
Park, Y.-G., Sohn, C. H., Chen, R., McCue, M., Yun, D. H., Drummond, G. T., Ku, T., Evans, N. B., Oak, H. C., Trieu, W., et al. (2019) · Nature Biotechnology · doi:10.1038/nbt.4281 · Cited by 421
Artificial intelligence for digital and computational pathology
Song, A. H., Jaume, G., Williamson, D. F. K., Lu, M. Y., Vaidya, A., Miller, T. R., & Mahmood, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00096-8 · Cited by 356
Metadata
- Authors
- Glaser, A. K., Reder, N. P., Chen, Y., McCarty, E. F., Yin, C., Wei, L., Wang, Y., True, L. D., & Liu, J. T. C.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-06-26
- Volume
- 1
- Issue
- 7
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2700381762
- Cited by
- 419
- References
- 49
- FWCI
- 19.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.