Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 500

The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.

Quantitative prediction of human pharmacokinetic responses to drugs via fluidically coupled vascularized organ chips

Open access
Herland, Anna, Maoz, Ben M., Das, Debarun, Somayaji, Mahadevabharath R., Prantil-Baun, Rachelle, Novak, Richard, Cronce, Michael, Huffstater, Tessa, Jeanty, Sauveur S. F., Ingram, Miles, Chalkiadaki, Angeliki, Benson Chou, David, Marquez, Susan, Delahanty, Aaron, Jalili-Firoozinezhad, Sasan, Milton, Yuka, Sontheimer-Phelps, Alexandra, Swenor, Ben, Levy, Oren, Parker, Kevin K., Przekwas, Andrzej, Ingber, Donald E.·2020·Nature Biomedical Engineering

Abstract

Analyses of drug pharmacokinetics (PKs) and pharmacodynamics (PDs) performed in animals are often not predictive of drug PKs and PDs in humans, and in vitro PK and PD modelling does not provide quantitative PK parameters. Here, we show that physiological PK modelling of first-pass drug absorption, metabolism and excretion in humans—using computationally scaled data from multiple fluidically linked two-channel organ chips—predicts PK parameters for orally administered nicotine (using gut, liver and kidney chips) and for intravenously injected cisplatin (using coupled bone marrow, liver and kidney chips). The chips are linked through sequential robotic liquid transfers of a common blood substitute by their endothelium-lined channels (as reported by Novak et al. in an associated Article) and share an arteriovenous fluid-mixing reservoir. We also show that predictions of cisplatin PDs match previously reported patient data. The quantitative in-vitro-to-in-vivo translation of PK and PD parameters and the prediction of drug absorption, distribution, metabolism, excretion and toxicity through fluidically coupled organ chips may improve the design of drug-administration regimens for phase-I clinical trials. Physiological modelling of first-pass metabolism using data from a robotic instrument that fluidically links relevant organ chips predicts human pharmacokinetic parameters for orally administered nicotine and for intravenously injected cisplatin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-019-0498-9

Cites

65 of 65 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 65 references

Cited by

See all 500

Metadata

Authors
Herland, A., Maoz, B. M., Das, D., Somayaji, M. R., Prantil-Baun, R., Novak, R., Cronce, M., Huffstater, T., Jeanty, S. S. F., Ingram, M., Chalkiadaki, A., Benson Chou, D., Marquez, S., Delahanty, A., Jalili-Firoozinezhad, S., Milton, Y., Sontheimer-Phelps, A., Swenor, B., Levy, O., Parker, K. K., Przekwas, A., & Ingber, D. E.
Venue
Nature Biomedical Engineering
Published
2020-01-27
Volume
4
Issue
4
Pages
421-436
ISSN
2157-846X (ISSN-L)
OpenAlex
W3002451359
Cited by
500
References
65
FWCI
20.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative prediction of human pharmacokinetic responses to drugs via fluidically coupled vascularized organ chips. https://app.cochat.ai/papers/10.1038/s41551-019-0498-9
The paper
Herland, A., Maoz, B. M., Das, D., Somayaji, M. R., Prantil-Baun, R., Novak, R., Cronce, M., Huffstater, T., Jeanty, S. S. F., Ingram, M., Chalkiadaki, A., Benson Chou, D., Marquez, S., Delahanty, A., Jalili-Firoozinezhad, S., Milton, Y., Sontheimer-Phelps, A., Swenor, B., Levy, O., . . . Ingber, D. E. (2020). Quantitative prediction of human pharmacokinetic responses to drugs via fluidically coupled vascularized organ chips. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-019-0498-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.