Cited by 62Advanced Sensor and Energy Harvesting MaterialsConducting polymers and applicationsNeuroscience and Neural Engineering

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Electrochemiluminescent tactile visual synapse enabling in situ health monitoring

Abstract

Tactile visual synapses combine the functionality of tactile artificial synapses with the ability to visualize their activity in real time and provide a direct and intuitive visualization of the activity, offering an efficient route for in situ health monitoring. Herein we present a tactile visual synapse that enables in situ monitoring of finger rehabilitation and electrocardiogram analysis. Repetitive finger flexion and various arrhythmias are monitored and visually guided using the developed tactile visual synapse combined with an electrical and optical output feedback algorithm. The tactile visual synapse has the structure of an electrochemical transistor comprising an elastomeric top gate as a tactile receptor and an electrochemiluminescent ion gel as a light-emitting layer stacked on a polymeric semiconductor layer, forming an electrical synaptic channel between source and drain electrodes. The low-power (~34 μW) visualization of the tactile synaptic activity associated with the repetitive motions of fingers and heartbeats enables the development of a convenient and efficient personalized healthcare system.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41563-025-02124-x

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Kim, W., Lee, K., Choi, S., Park, E., Kim, G., Ha, J., Kim, Y., Jang, J., Oh, J. H., Kim, H., Jiang, W., Yoo, J., Kim, T., Kim, Y., Kim, K.-N., Hong, J., Javey, A., Rha, D.-W., Lee, T.-W., Kang, K., Wang, G., & Park, C.
Affiliations
  • Yonsei University (KR)
  • Lawrence Berkeley National Laboratory (US)
  • University of California, Santa Barbara (US)
  • Seoul National University (KR)
  • Korea University (KR)
Corresponding author
  • Wang, Gunuk
  • Park, Cheolmin
Venue
Nature Materials
Published
2025-02-24
Volume
24
Issue
6
Pages
925-934
ISSN
  • 1476-1122 (ISSN-L)
  • 1476-4660
OpenAlex
W4407884150
Cited by
62
References
42
Citations by year
2026: 42 · 2025: 20
FWCI
14.91
Type
journal article
Language
en
Open access
closed
Locations
  • Nature Materials (publishedVersion)
  • PubMed (publishedVersion)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
  • Ministry of Science, ICT and Future Planning (NRF-2022M3C1A3081211, RS-2024-00451891, RS-2024-00416938)
  • Korea Institute of Science and Technology (2E32961)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
electrochemiluminescence, artificial synapses, electrochemical transistors, ionic gels, ECG monitoring, arrhythmia detection
MeSH terms
Fingers, Humans, Monitoring, Physiologic, Semiconductors, Touch, Transistors, Electronic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review