Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Measurement of the fine-structure constant as a test of the Standard Model

Open access
Parker, Richard H., Yu, Chenghui, Zhong, Weicheng, Estey, Brian, Müller, Holger·2018·Science

Abstract

Refining the fine-structure constant: The fine-structure constant, α, is a dimensionless constant that characterizes the strength of the electromagnetic interaction between charged elementary particles. Related by four fundamental constants, a precise determination of α allows for a test of the Standard Model of particle physics. Parker et al. used matter-wave interferometry with a cloud of cesium atoms to make the most accurate measurement of α to date. Determining the value of α to an accuracy of better than 1 part per billion provides an independent method for testing the accuracy of quantum electrodynamics and the Standard Model. It may also enable searches of the so-called “dark sector” for explanations of dark matter. Science , this issue p. 191

Overview

Integrity signals

Registry

Crossref · 10.1126/science.aap7706

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 26 references

Research works printed but not linked: 3

  1. G. M. Tino M. A. Kasevich Eds. Atom Interferometry (Proceedings of the International School of Physics “Enrico Fermi ” Course CLXXXVIII Societa Italiana di Fisica and IOS Press 2014).
  2. S. Bade L. Djadaojee M. Andia P. Cladé S. Guellati-Khélifa Photon momentum in a distorted optical field arXiv:1712.04023 [physics.atom-ph] (11 December 2017). · arXiv
  3. G. Gabrielse S. F. Hoogerheide J. Dorr E. Novitski in Fundamental Physics in Particle Traps W. Quint M. Vogel Eds. (Springer Tracts in Modern Physics Series Springer 2014) vol. 256.

Cited by

See all 917

Metadata

Authors
Parker, R. H., Yu, C., Zhong, W., Estey, B., & Müller, H.
Affiliations
  • University of California, Berkeley (US)
  • Lawrence Berkeley National Laboratory (US)
Corresponding author
  • Parker, Richard H.
  • Yu, Chenghui
  • Müller, Holger
Venue
Science
Published
2018-04-13
Volume
360
Issue
6385
Pages
191-195
ISSN
  • 0036-8075 (ISSN-L)
  • 1095-9203
OpenAlex
W2798096064
Cited by
917
References
26
Citations by year
2026: 64 · 2025: 84 · 2024: 109 · 2023: 109 · 2022: 120 · 2021: 160 · 2020: 158 · 2019: 88 · 2018: 25
FWCI
49.81
Type
journal article
Language
en
Open access
Locations
  • Science (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
Funders
  • National Science Foundation (PHY-1056620, PHY-0923445)
  • David and Lucile Packard Foundation (2009-34712)
  • National Institute of Standards and Technology (60NANB9D9169)
  • Alfred P. Sloan Foundation (BR-5044)
  • Jet Propulsion Laboratory (1531033, 1553641, 1458850, 1483242)
  • University of California Office of the President (040219)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
  • Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle physics theoretical and experimental studies
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
fine-structure constant, matter-wave interferometry, cesium atoms, quantum electrodynamics, Standard Model tests, dark matter, dark sector, precision measurement

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of the fine-structure constant as a test of the Standard Model. https://app.cochat.ai/papers/10.1126/science.aap7706
The paper
Parker, R. H., Yu, C., Zhong, W., Estey, B., & Müller, H. (2018). Measurement of the fine-structure constant as a test of the Standard Model. Science. https://doi.org/10.1126/science.aap7706

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.