Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index; 18 of the 36 sources its claims cite were checked for support.

Data-driven de novo design of super-adhesive hydrogels

Open access

Published version of a preprint

Abstract

Data-driven methodologies have transformed the discovery and prediction of hard materials with well-defined atomic structures by leveraging standardized datasets, enabling accurate property predictions and facilitating efficient exploration of design spaces1–3. However, their application to soft materials remains challenging because of complex, multiscale structure–property relationships4–6. Here we present a data-driven approach that integrates data mining, experimentation and machine learning to design high-performance adhesive hydrogels from scratch, tailored for demanding underwater environments. By leveraging protein databases, we developed a descriptor strategy to statistically replicate protein sequence patterns in polymer strands by ideal random copolymerization, enabling targeted hydrogel design and dataset construction. Using machine learning, we optimized hydrogel formulations from an initial dataset of 180 bioinspired hydrogels, achieving remarkable improvements in adhesive strength, with a maximum value exceeding 1 MPa. These super-adhesive hydrogels hold immense potential across diverse applications, from biomedical engineering to deep-sea exploration, marking a notable advancement in data-driven innovation for soft materials. A data-driven approach integrates data mining, experimentation and machine learning to design high-performance adhesive hydrogels from scratch, tailored for demanding underwater environments.

Overview

CoChat Summary

TL;DR

This paper integrates adhesive-protein data mining, hydrogel synthesis, and machine learning to design underwater adhesive hydrogels from scratch. Starting from 180 bioinspired formulations, ML optimization produced hydrogels with maximum underwater adhesive strength exceeding 1 MPa on glass in normal saline.

Key findings

  • Mining 24,707 adhesive proteins from 3,822 organisms and selecting the top 200 species yielded 180 unique monomer compositions after removing 20 duplicates; these were used to synthesize DM-driven hydrogels.
  • Among the 180 DM-driven hydrogels, 16 showed adhesive strength \(F_a > 100\) kPa and 83 showed \(F_a > 46\) kPa; the best, G-042/G-max, reached 147 kPa.
  • ML optimization expanded the dataset to 341 hydrogels; R1-max achieved maximum \(F_a > 1\) MPa on glass in normal saline, maintained robust adhesion over 200 attachment–detachment cycles, and sustained a 1-kg shear load for over 1 year.
  • SHAP analysis showed high \(\phi_{BA}\) and \(\phi_{PEA}\) enhance \(F_a\), high \(\phi_{HEA}\), \(\phi_{CBEA}\), and \(\phi_{AAm}\) reduce it, and \(\phi_{ATAC}\) has a dual effect; the top ML hydrogels were composed exclusively of BA, PEA, and ATAC.

Methods

  • Adhesive protein data were compiled from NCBI using the keyword “adhesive protein”; consensus sequences for the top 200 species were generated with Clustal Omega, and the 20 canonical amino acids were grouped into six physicochemical classes. Relative compositions were derived from the top five functional-class pairs, accounting for approximately 50% of occurrences.
  • Hydrogels were synthesized by one-pot free-radical copolymerization of six functional monomers in DMSO with 0.1 mol% crosslinker and 2.4 M total monomer, then solvent-exchanged to normal saline. Underwater adhesion was screened by tack tests on glass in normal saline using a 10-N loading force and 10-s contact time; lap shear and 180° peeling tests were also used.
  • ML used a six-dimensional monomer-proportion feature vector to predict \(F_a\). Nine models were benchmarked; Gaussian process and random forest regression were selected as base models, and batched sequential model-based optimization with expected improvement proposed new formulations. Validation rounds expanded the dataset from 180 to 341 hydrogels.

Limitations

  • The paper states that challenges remain because of limitations in monomer diversity, polymer synthesis technologies for controlling monomer sequences at a scale suitable for materials development, and dataset scalability. It also states that the performance plateau after the first ML round was suspected to arise from the functionalities of the adopted monomer species, and that further optimization rounds were not pursued.
  • The paper notes that hydrogel performance varies with environmental conditions, underscoring the importance of data consistency in ML optimization.
  • Evident from the text: the initial dataset was small (180 hydrogels) and the final dataset remained limited (341 hydrogels); only six functional monomers were used, and the clearest design principle is for adhesion to glass surfaces using BA, PEA, and ATAC.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41586-025-09269-4

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Data-driven de novo design of underwater adhesive hydrogels. a, Conceptual scheme of the proposed approach integrating DM, experimentation and ML to design high-performance adhesive hydrogels. b, Comparison of underwater adhesive strength (Fa) between previously reported hydrogels (Supplementary Table 1) and newly developed hydrogels in this study (DM-driven and ML-driven). Fa was measured using tack tests, and the testing conditions were optimized for maximum performance.
Fig. 1 Data-driven de novo design of underwater adhesive hydrogels. a, Conceptual scheme of the proposed approach integrating DM, experimentation and ML to design high-performance adhesive hydrogels. b, Comparison of underwater adhesive strength (Fa) between previously reported hydrogels (Supplementary Table 1) and newly developed hydrogels in this study (DM-driven and ML-driven). Fa was measured using tack tests, and the testing conditions were optimized for maximum performance.CC BY-NC-ND · PubMed Central
Fig. 2 DM of adhesive proteins and formulation design. a, Schematic of the amino acids feature extraction process used to derive bioinspired formulations through adhesive protein DM, encoding and relative composition computation. b, Distribution of block length (that is, the number of consecutive residues from the same functional class) for the six functional classes, shown along the horizontal axis, based on the consensus sequences of the top 200 species. c, Pairwise frequency distribution of the 21 functional class pair types along encoded sequences, shown for the entire dataset and for eight representative species, shown along the horizontal axis, categorized by their biological classifications in the database.
Fig. 2 DM of adhesive proteins and formulation design. a, Schematic of the amino acids feature extraction process used to derive bioinspired formulations through adhesive protein DM, encoding and relative composition computation. b, Distribution of block length (that is, the number of consecutive residues from the same functional class) for the six functional classes, shown along the horizontal axis, based on the consensus sequences of the top 200 species. c, Pairwise frequency distribution of the 21 functional class pair types along encoded sequences, shown for the entire dataset and for eight representative species, shown along the horizontal axis, categorized by their biological classifications in the database.CC BY-NC-ND · PubMed Central
Fig. 3 DM-driven hydrogels for underwater adhesion. a, Chemical structures of six functional monomers, each representing one of the six functional classes of amino acids. b, Distribution of monomer block lengths in heteropolymer sequences generated by Monte Carlo simulations based on experimentally determined reactivity ratios and derived formulations. c, Pairwise frequency distribution of monomer pairs in heteropolymer sequences obtained by Monte Carlo simulations, shown for all 180 derived formulations and for eight formulations (denoted by gel index) corresponding to the representative species shown in Fig. 2c. d, Schematic of the tack test for measuring underwater adhesion. e, Adhesive strength (Fa) of the 180 hydrogels. f, Stress–displacement profiles of two G-004 variants in the tack test: (i) statistical sequences synthesized in DMSO and (ii) block-like sequences synthesized in DMS. Inset images show the appearance of the two hydrogels. Adhesion tests were conducted under a 10-N loading force applied for 10 s on a glass substrate in normal saline (0.154 M NaCl). This test condition was used for rapid screening.
Fig. 3 DM-driven hydrogels for underwater adhesion. a, Chemical structures of six functional monomers, each representing one of the six functional classes of amino acids. b, Distribution of monomer block lengths in heteropolymer sequences generated by Monte Carlo simulations based on experimentally determined reactivity ratios and derived formulations. c, Pairwise frequency distribution of monomer pairs in heteropolymer sequences obtained by Monte Carlo simulations, shown for all 180 derived formulations and for eight formulations (denoted by gel index) corresponding to the representative species shown in Fig. 2c. d, Schematic of the tack test for measuring underwater adhesion. e, Adhesive strength (Fa) of the 180 hydrogels. f, Stress–displacement profiles of two G-004 variants in the tack test: (i) statistical sequences synthesized in DMSO and (ii) block-like sequences synthesized in DMS. Inset images show the appearance of the two hydrogels. Adhesion tests were conducted under a 10-N loading force applied for 10 s on a glass substrate in normal saline (0.154 M NaCl). This test condition was used for rapid screening.CC BY-NC-ND · PubMed Central
Fig. 4 ML optimization of underwater adhesive hydrogels. a, Adhesive strength (Fa) of hydrogels fabricated based on predictions from various models trained on the 180-hydrogel dataset. The model nomenclature and detailed descriptions are provided in the Methods. All adhesion measurements were performed under the same test conditions as the training set: 10 N loading force, 10-s contact time, on a glass substrate and in normal saline. b, UMAP representation of the relationship between Fa and reduced monomer proportions (ϕi), highlighting the formulations proposed by GP_KB and RFR-GP (within the SMBO framework) across different rounds. Symbol size represents the magnitude of adhesive strength. c, SHAP beeswarm plot, ranked by mean absolute SHAP values, showing the influence of ϕi on Fa within the final dataset of 341 samples as analysed by the trained RFR model.
Fig. 4 ML optimization of underwater adhesive hydrogels. a, Adhesive strength (Fa) of hydrogels fabricated based on predictions from various models trained on the 180-hydrogel dataset. The model nomenclature and detailed descriptions are provided in the Methods. All adhesion measurements were performed under the same test conditions as the training set: 10 N loading force, 10-s contact time, on a glass substrate and in normal saline. b, UMAP representation of the relationship between Fa and reduced monomer proportions (ϕi), highlighting the formulations proposed by GP_KB and RFR-GP (within the SMBO framework) across different rounds. Symbol size represents the magnitude of adhesive strength. c, SHAP beeswarm plot, ranked by mean absolute SHAP values, showing the influence of ϕi on Fa within the final dataset of 341 samples as analysed by the trained RFR model.CC BY-NC-ND · PubMed Central
Fig. 5 Characterization and performance of hydrogels identified by DM (G-max) and ML optimization (R1-max, R2-max and R3-max). a, Formulations of the gels. b, Photographic images showing the appearance of the gels. c, Uniaxial tensile stress–strain curves of the gels at a stretch rate of 100 mm min−1. d, Fa of hydrogels as a function of contact time (left) and contact force (right) on glass in normal saline. e, Fa of R1-max on various substrates in normal saline. PC, polycarbonate; PMMA, poly(methyl methacrylate); PF, phenol formaldehyde; POM, polyoxymethylene; PP, polypropylene; PTFE, polytetrafluoroethylene; Al, aluminium alloy; Ti, titanium alloy; SS, stainless steel. f, Photographic image showing R1-max (25 mm × 25 mm in size, about 0.4 mm thickness) joining pairs of ceramics (left), glass (middle) and titanium (right) plates under a 1-kg load in normal saline for over 1 year. g, Fa on glass substrate in deionized water, normal saline and artificial seawater (0.7 M NaCl) for hydrogels equilibrated in the corresponding solutions. The asterisk on G-max indicates cohesive failure during testing. Error bars represent the standard deviation of N = 3 measurements.
Fig. 5 Characterization and performance of hydrogels identified by DM (G-max) and ML optimization (R1-max, R2-max and R3-max). a, Formulations of the gels. b, Photographic images showing the appearance of the gels. c, Uniaxial tensile stress–strain curves of the gels at a stretch rate of 100 mm min−1. d, Fa of hydrogels as a function of contact time (left) and contact force (right) on glass in normal saline. e, Fa of R1-max on various substrates in normal saline. PC, polycarbonate; PMMA, poly(methyl methacrylate); PF, phenol formaldehyde; POM, polyoxymethylene; PP, polypropylene; PTFE, polytetrafluoroethylene; Al, aluminium alloy; Ti, titanium alloy; SS, stainless steel. f, Photographic image showing R1-max (25 mm × 25 mm in size, about 0.4 mm thickness) joining pairs of ceramics (left), glass (middle) and titanium (right) plates under a 1-kg load in normal saline for over 1 year. g, Fa on glass substrate in deionized water, normal saline and artificial seawater (0.7 M NaCl) for hydrogels equilibrated in the corresponding solutions. The asterisk on G-max indicates cohesive failure during testing. Error bars represent the standard deviation of N = 3 measurements.CC BY-NC-ND · PubMed Central
Extended Data Fig. 1 Sequence analysis of Enterobacteriaceae adhesive proteins. (a) Consensus sequence fragment. (b) Pairwise functional class counts within the consensus sequence fragment. Complete data for the top 200 species are provided in Supplementary Data 1 and Supplementary Data 2.
Extended Data Fig. 1 Sequence analysis of Enterobacteriaceae adhesive proteins. (a) Consensus sequence fragment. (b) Pairwise functional class counts within the consensus sequence fragment. Complete data for the top 200 species are provided in Supplementary Data 1 and Supplementary Data 2.CC BY-NC-ND · PubMed Central
Extended Data Fig. 2 Data mining-driven hydrogels based on the resilin protein database. (a) Pairwise frequency distribution of 21 functional class pair types in encoded consensus sequences for adhesive and resilin proteins from data mining (DM). The resilin dataset comprises 2,537 proteins sourced from the NCBI protein database using the keyword “resilin.” (b) Average monomer proportions in formulations derived from adhesive and resilin protein databases. (c) Adhesive strength (Fa) of DM-driven hydrogels derived from the resilin protein database. Asterisks indicate significant gel shrinkage during solvent exchange, making adhesion testing unfeasible for these samples. Detailed formulations are included in Supplementary Table 7. Adhesion tests were performed on a glass substrate in normal saline using a tack test with a 10 N loading force and a 10-s contact time, consistent with conditions used for DM-driven hydrogels derived from adhesive proteins. Error bars represent the standard deviation of N = 3 measurements. (d) Comparison of average Fa between DM-driven hydrogels derived from adhesive and resilin protein databases.
Extended Data Fig. 2 Data mining-driven hydrogels based on the resilin protein database. (a) Pairwise frequency distribution of 21 functional class pair types in encoded consensus sequences for adhesive and resilin proteins from data mining (DM). The resilin dataset comprises 2,537 proteins sourced from the NCBI protein database using the keyword “resilin.” (b) Average monomer proportions in formulations derived from adhesive and resilin protein databases. (c) Adhesive strength (Fa) of DM-driven hydrogels derived from the resilin protein database. Asterisks indicate significant gel shrinkage during solvent exchange, making adhesion testing unfeasible for these samples. Detailed formulations are included in Supplementary Table 7. Adhesion tests were performed on a glass substrate in normal saline using a tack test with a 10 N loading force and a 10-s contact time, consistent with conditions used for DM-driven hydrogels derived from adhesive proteins. Error bars represent the standard deviation of N = 3 measurements. (d) Comparison of average Fa between DM-driven hydrogels derived from adhesive and resilin protein databases.CC BY-NC-ND · PubMed Central
Extended Data Fig. 3 Analysis of correlations between adhesive strength (Fa) and properties of 180 bioinspired hydrogels. (a) Correlation between monomer proportions (ϕi) and Fa, captured by Kendall’s τ coefficients. These coefficients reveal that ϕBA, ϕATAC, and ϕPEA have weak positive correlations with Fa, while ϕHEA, ϕAAm, and ϕCBEA show weak negative correlations. (b) Example illustrating the complex interplay between ϕi and Fa, due to the synergistic effects of different monomers. Comparing G-074 to G-001, ϕBA is roughly the same, ϕHEA and ϕCBEA increase, and ϕATAC decreases. Despite Kendall’s τ coefficients suggesting that the Fa of G-074 should be lower than that of G-001, the actual Fa of G-074 is about five times higher. (c) Angular frequency dependence of the storage modulus (G′) and loss modulus (G″) of the G-042 hydrogel as an example. The slope (k) of G′ is calculated from the line connecting G′ values at frequencies of 0.1 and 100 rad s−1. A larger slope indicates greater viscoelasticity of the hydrogel. (d) Fa as a function of network properties for the 180 bioinspired hydrogels. Q, G′, Tan δ = G″/G′, and k represent the volume swelling ratio, storage modulus at a frequency of 100 rad s−1, loss factor at a frequency of 100 rad s−1, and the slope of the G′ curve, respectively. These results suggest that hydrogels with shrinking behavior (Q < 1), moderate G′, high Tan δ, and moderate k tend to exhibit higher Fa values. All characterizations were performed on gels equilibrated in normal saline (0.154 M NaCl). Adhesion tests were conducted using a tack test with a 10 N loading force and a 10-s contact time on a glass substrate to enable rapid screening and ensure consistent comparisons across the dataset.
Extended Data Fig. 3 Analysis of correlations between adhesive strength (Fa) and properties of 180 bioinspired hydrogels. (a) Correlation between monomer proportions (ϕi) and Fa, captured by Kendall’s τ coefficients. These coefficients reveal that ϕBA, ϕATAC, and ϕPEA have weak positive correlations with Fa, while ϕHEA, ϕAAm, and ϕCBEA show weak negative correlations. (b) Example illustrating the complex interplay between ϕi and Fa, due to the synergistic effects of different monomers. Comparing G-074 to G-001, ϕBA is roughly the same, ϕHEA and ϕCBEA increase, and ϕATAC decreases. Despite Kendall’s τ coefficients suggesting that the Fa of G-074 should be lower than that of G-001, the actual Fa of G-074 is about five times higher. (c) Angular frequency dependence of the storage modulus (G′) and loss modulus (G″) of the G-042 hydrogel as an example. The slope (k) of G′ is calculated from the line connecting G′ values at frequencies of 0.1 and 100 rad s−1. A larger slope indicates greater viscoelasticity of the hydrogel. (d) Fa as a function of network properties for the 180 bioinspired hydrogels. Q, G′, Tan δ = G″/G′, and k represent the volume swelling ratio, storage modulus at a frequency of 100 rad s−1, loss factor at a frequency of 100 rad s−1, and the slope of the G′ curve, respectively. These results suggest that hydrogels with shrinking behavior (Q < 1), moderate G′, high Tan δ, and moderate k tend to exhibit higher Fa values. All characterizations were performed on gels equilibrated in normal saline (0.154 M NaCl). Adhesion tests were conducted using a tack test with a 10 N loading force and a 10-s contact time on a glass substrate to enable rapid screening and ensure consistent comparisons across the dataset.CC BY-NC-ND · PubMed Central
Extended Data Fig. 4 Machine learning (ML) trained models. (a) Error plots for nine ML models using a 90%/10% training-test split. Training data points are represented by blue dots, while test data points are shown in red. The dashed line indicates where the predicted values match the experimental data (truth). (b) Root mean squared errors (RMSEs) depicting the prediction accuracy across the nine ML models trained on the dataset of 180 bioinspired hydrogels, assessed via 10-fold cross-validation. A lower test error, combined with minimized overfitting (i.e., a smaller gap between training and test errors), indicates a more effective regression model.
Extended Data Fig. 4 Machine learning (ML) trained models. (a) Error plots for nine ML models using a 90%/10% training-test split. Training data points are represented by blue dots, while test data points are shown in red. The dashed line indicates where the predicted values match the experimental data (truth). (b) Root mean squared errors (RMSEs) depicting the prediction accuracy across the nine ML models trained on the dataset of 180 bioinspired hydrogels, assessed via 10-fold cross-validation. A lower test error, combined with minimized overfitting (i.e., a smaller gap between training and test errors), indicates a more effective regression model.CC BY-NC-ND · PubMed Central
Extended Data Fig. 5 Machine learning-driven optimization and experimental validation in three consecutive rounds. (a) Adhesive strength (Fa) of hydrogels fabricated in experiments according to the formulations proposed by GP_KB and RFR-GP models. (b) Variations in performance metrics, including: (i) successful rate (SR), defined as the fraction of the test set with higher true Fa than the training set; (ii) ratio of maximum true Fa between the test and training sets; and (iii) root mean squared errors (RMSEs) of the test sets. The success rate and Fa ratio decrease from the first round to the second round and level off in the third round, implying convergence toward the global optimum via SMBO. Meanwhile, the RMSE decreases continuously over the three rounds, indicating that expanding the training dataset improves the accuracy of regression models. (c) Parity plots comparing ML predicted Fa versus true Fa.
Extended Data Fig. 5 Machine learning-driven optimization and experimental validation in three consecutive rounds. (a) Adhesive strength (Fa) of hydrogels fabricated in experiments according to the formulations proposed by GP_KB and RFR-GP models. (b) Variations in performance metrics, including: (i) successful rate (SR), defined as the fraction of the test set with higher true Fa than the training set; (ii) ratio of maximum true Fa between the test and training sets; and (iii) root mean squared errors (RMSEs) of the test sets. The success rate and Fa ratio decrease from the first round to the second round and level off in the third round, implying convergence toward the global optimum via SMBO. Meanwhile, the RMSE decreases continuously over the three rounds, indicating that expanding the training dataset improves the accuracy of regression models. (c) Parity plots comparing ML predicted Fa versus true Fa.CC BY-NC-ND · PubMed Central
Extended Data Fig. 6 Properties of top-performing hydrogels from machine learning and data mining approaches. (a) Angular frequency dependence of storage modulus (G′) and loss modulus (G″) for the top-performing machine learning-driven gels (R1-max, R2-max, R3-max) and the top-performing data mining-driven gel (G-max) in DMSO. (b) Angular frequency dependence of G′ and G″ for the four hydrogels equilibrated in normal saline (0.154 M NaCl). (c) Volume swelling ratio (Q) of the four hydrogels equilibrated in normal saline relative to their as-prepared state in DMSO. (d) Pure shear stress-stretch ratio curves for the R1-max hydrogel (equilibrated in normal saline) with and without a notch, measured at a stretch rate of 100 mm min−1. The notched sample exhibited crack propagation at a critical stretch ratio (λc) of 3.4. The fracture energy (Γ) estimated from the pure-shear test is shown. Experimental details are provided in the Supplementary Materials. Error bars represent the standard deviation of N = 3 measurements.
Extended Data Fig. 6 Properties of top-performing hydrogels from machine learning and data mining approaches. (a) Angular frequency dependence of storage modulus (G′) and loss modulus (G″) for the top-performing machine learning-driven gels (R1-max, R2-max, R3-max) and the top-performing data mining-driven gel (G-max) in DMSO. (b) Angular frequency dependence of G′ and G″ for the four hydrogels equilibrated in normal saline (0.154 M NaCl). (c) Volume swelling ratio (Q) of the four hydrogels equilibrated in normal saline relative to their as-prepared state in DMSO. (d) Pure shear stress-stretch ratio curves for the R1-max hydrogel (equilibrated in normal saline) with and without a notch, measured at a stretch rate of 100 mm min−1. The notched sample exhibited crack propagation at a critical stretch ratio (λc) of 3.4. The fracture energy (Γ) estimated from the pure-shear test is shown. Experimental details are provided in the Supplementary Materials. Error bars represent the standard deviation of N = 3 measurements.CC BY-NC-ND · PubMed Central
Extended Data Fig. 7 Adhesive strength (Fa) of hydrogels under different tack test conditions. (a, b) Force-displacement curves of G-max hydrogel: (a) at a fixed loading force of 10 N with varying contact times, and (b) at a fixed contact time of 60 s with varying loading forces. (c, d) Force-displacement curves of R1-max hydrogel: (c) at a fixed loading force of 10 N with varying contact times, and (d) at a fixed contact time of 60 s with varying loading forces. (e) Fa of the 10 samples that exhibited high adhesions in Fig. 3e measured at different loading force and contact time. All adhesion tests were conducted in normal saline on glass substrates. Error bars represent the standard deviation of N = 3 measurements.
Extended Data Fig. 7 Adhesive strength (Fa) of hydrogels under different tack test conditions. (a, b) Force-displacement curves of G-max hydrogel: (a) at a fixed loading force of 10 N with varying contact times, and (b) at a fixed contact time of 60 s with varying loading forces. (c, d) Force-displacement curves of R1-max hydrogel: (c) at a fixed loading force of 10 N with varying contact times, and (d) at a fixed contact time of 60 s with varying loading forces. (e) Fa of the 10 samples that exhibited high adhesions in Fig. 3e measured at different loading force and contact time. All adhesion tests were conducted in normal saline on glass substrates. Error bars represent the standard deviation of N = 3 measurements.CC BY-NC-ND · PubMed Central
Extended Data Fig. 8 Repeated adhesion of the R1-max hydrogel. Adhesion stability of the R1-max hydrogel (10 mm diameter, ~0.4 mm thickness) over 200 attachment-detachment cycles on a glass substrate in normal saline. Testing was conducted under a 5 N loading force and a 10-s contact time.
Extended Data Fig. 8 Repeated adhesion of the R1-max hydrogel. Adhesion stability of the R1-max hydrogel (10 mm diameter, ~0.4 mm thickness) over 200 attachment-detachment cycles on a glass substrate in normal saline. Testing was conducted under a 5 N loading force and a 10-s contact time.CC BY-NC-ND · PubMed Central
Extended Data Fig. 9 Adhesion performance of the R1-max hydrogel on various substrates. (a) Schematic illustration of lap shear and 180° peeling tests for adhesion assessment. (b) Force-displacement curves from lap shear tests of R1-max (10 mm diameter, ~0.4 mm thickness) adhering to glass, PET, and PC substrates. (c) Force-displacement curves from 180° peeling tests of R1-max (10 mm × 150 mm strips, ~0.4 mm thickness) adhering to glass, PET, PC, and pork bone surfaces. (d) Lap shear adhesive strength and 180° peeling interfacial toughness of R1-max on various substrates. (e) Photographic images (from different perspective angles) showing R1-max (25 mm × 150 mm strips, ~0.4 mm thickness) being peeled away from a pork bone surface. All hydrogels were equilibrated in normal saline before testing. Error bars represent the standard deviation of N = 3 measurements. Experimental details are provided in the Methods section. These results highlight the exceptional adhesion performance of R1-max on various surfaces.
Extended Data Fig. 9 Adhesion performance of the R1-max hydrogel on various substrates. (a) Schematic illustration of lap shear and 180° peeling tests for adhesion assessment. (b) Force-displacement curves from lap shear tests of R1-max (10 mm diameter, ~0.4 mm thickness) adhering to glass, PET, and PC substrates. (c) Force-displacement curves from 180° peeling tests of R1-max (10 mm × 150 mm strips, ~0.4 mm thickness) adhering to glass, PET, PC, and pork bone surfaces. (d) Lap shear adhesive strength and 180° peeling interfacial toughness of R1-max on various substrates. (e) Photographic images (from different perspective angles) showing R1-max (25 mm × 150 mm strips, ~0.4 mm thickness) being peeled away from a pork bone surface. All hydrogels were equilibrated in normal saline before testing. Error bars represent the standard deviation of N = 3 measurements. Experimental details are provided in the Methods section. These results highlight the exceptional adhesion performance of R1-max on various surfaces.CC BY-NC-ND · PubMed Central
Extended Data Fig. 10 Demonstration of data-driven hydrogels in practical applications. (a) Photographic images of R1-max adhering a rubber duck to a seaside rock, withstanding ocean tides. (b) Photographic images of R2-max (6 cm × 6 cm in size, ~0.37 mm thickness) sealing a 20-mm-diameter hole at the base of a 3-meter-tall PC pipe to halt high-pressure water leakage (burst flow rate at the outlet of the hole was ~5.4 m s−1). (c) Photographic images show (i) R2-max successfully repairing a 20 mm hole at the base of a 3-meter-tall polycarbonate pipe filled with tap water; (ii) no water leakage was observed for over 5 months in air, with the gel becoming transparent upon drying, and the opaque region indicating water penetration only around the hole; (iii) in contrast, commercial FLEX TAPE® failed under the same conditions, with water leakage occurring within 1.5 h. These findings highlight the exceptional wet adhesion performance of the R2-max hydrogel.
Extended Data Fig. 10 Demonstration of data-driven hydrogels in practical applications. (a) Photographic images of R1-max adhering a rubber duck to a seaside rock, withstanding ocean tides. (b) Photographic images of R2-max (6 cm × 6 cm in size, ~0.37 mm thickness) sealing a 20-mm-diameter hole at the base of a 3-meter-tall PC pipe to halt high-pressure water leakage (burst flow rate at the outlet of the hole was ~5.4 m s−1). (c) Photographic images show (i) R2-max successfully repairing a 20 mm hole at the base of a 3-meter-tall polycarbonate pipe filled with tap water; (ii) no water leakage was observed for over 5 months in air, with the gel becoming transparent upon drying, and the opaque region indicating water penetration only around the hole; (iii) in contrast, commercial FLEX TAPE® failed under the same conditions, with water leakage occurring within 1.5 h. These findings highlight the exceptional wet adhesion performance of the R2-max hydrogel.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

8 Valid · 2 Not valid · 9 Not checked · 81 Own results and interpretations

61 more claims

Create a free account to see all 100 claims and to verify the 2 references still open.

See all claims — free account
  • Probably not a substantial claim. 17
  • It may state two separate claims as one. 23

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 49 references

Research works printed but not linked: 2

  1. Myers, R. H., Montgomery, D. C. & Anderson-Cook, C. M. Response Surface Methodology: Process and Product Optimization Using Designed Experiments (Wiley, 2016).
  2. González, J., Dai, Z., Hennig, P. & Lawrence, N. Batch Bayesian optimization via local penalization. In Proc. Artificial Intelligence and Statistics 648–657 (PMLR, 2016).

Cited by

See all 169

Metadata

Authors
Liao, H., Hu, S., Yang, H., Wang, L., Tanaka, S., Takigawa, I., Li, W., Fan, H., & Gong, J. P.
Affiliations
  • Hokkaido University (JP)
  • Shenzhen University (CN)
Corresponding author
  • Takigawa, Ichigaku
  • Li, Wei
  • Fan, Hailong
  • Gong, Jian Ping
Venue
Nature
Published
2025-08-06
Volume
644
Issue
8075
Pages
89-95
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4413020503
Cited by
169
References
49
Citations by year
2026: 138 · 2025: 31
FWCI
35.49
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature (publishedVersion, cc-by-nc-nd)
  • Research Square (acceptedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Institutional Repositories DataBase (IRDB) (submittedVersion)
  • Kyoto University Research Information Repository (Kyoto University) (submittedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Machine Learning in Materials Science
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
Keywords
bioinspired polymers, protein sequence descriptors, random copolymerization, structure-property relationships, adhesion strength, wet adhesion
MeSH terms
Machine Learning, Adhesiveness, Adhesives, Proteins, Hydrogels, Databases, Protein, Data Mining, Polymerization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Data-driven de novo design of super-adhesive hydrogels. https://app.cochat.ai/papers/10.1038/s41586-025-09269-4
The paper
Liao, H., Hu, S., Yang, H., Wang, L., Tanaka, S., Takigawa, I., Li, W., Fan, H., & Gong, J. P. (2025). Data-driven de novo design of super-adhesive hydrogels. Nature. https://doi.org/10.1038/s41586-025-09269-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.