Cell-free biosensors for rapid detection of water contaminants

Open access
Jung, Jaeyoung K., Alam, Khalid K., Verosloff, Matthew S., Capdevila, Daiana A., Desmau, Morgane, Clauer, Phillip R., Lee, Jeong Wook, Nguyen, Peter Q., Pastén, Pablo A., Matiasek, Sandrine J., Gaillard, Jean-François, Giedroc, David P., Collins, James J., Lucks, Julius B.·2020·Nature Biotechnology

Abstract

Lack of access to safe drinking water is a global problem, and methods to reliably and easily detect contaminants could be transformative. We report the development of a cell-free in vitro transcription system that uses RNA Output Sensors Activated by Ligand Induction (ROSALIND) to detect contaminants in water. A combination of highly processive RNA polymerases, allosteric protein transcription factors and synthetic DNA transcription templates regulates the synthesis of a fluorescence-activating RNA aptamer. The presence of a target contaminant induces the transcription of the aptamer, and a fluorescent signal is produced. We apply ROSALIND to detect a range of water contaminants, including antibiotics, small molecules and metals. We also show that adding RNA circuitry can invert responses, reduce crosstalk and improve sensitivity without protein engineering. The ROSALIND system can be freeze-dried for easy storage and distribution, and we apply it in the field to test municipal water supplies, demonstrating its potential use for monitoring water quality. Water contaminants are detected with freeze-dried, regulated in vitro transcription reactions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41587-020-0571-7

Cites

82 of 82 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 82 references

Cited by

See all 402

Metadata

Authors
Jung, J. K., Alam, K. K., Verosloff, M. S., Capdevila, D. A., Desmau, M., Clauer, P. R., Lee, J. W., Nguyen, P. Q., Pastén, P. A., Matiasek, S. J., Gaillard, J.-F., Giedroc, D. P., Collins, J. J., & Lucks, J. B.
Venue
Nature Biotechnology
Published
2020-07-06
Volume
38
Issue
12
Pages
1451-1459
ISSN
  • 0733-222X (ISSN-L)
  • 1087-0156
  • 1546-1696
OpenAlex
W3039666655
Cited by
402
References
82
FWCI
13.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cell-free biosensors for rapid detection of water contaminants. https://app.cochat.ai/papers/10.1038/s41587-020-0571-7
The paper
Jung, J. K., Alam, K. K., Verosloff, M. S., Capdevila, D. A., Desmau, M., Clauer, P. R., Lee, J. W., Nguyen, P. Q., Pastén, P. A., Matiasek, S. J., Gaillard, J.-F., Giedroc, D. P., Collins, J. J., & Lucks, J. B. (2020). Cell-free biosensors for rapid detection of water contaminants. Nature Biotechnology. https://doi.org/10.1038/s41587-020-0571-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.