CoChat

An augmented reality microscope with real-time artificial intelligence integration for cancer diagnosis

Open access

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

The microscopic assessment of tissue samples is instrumental for the diagnosis and staging of cancer, and thus guides therapy. However, these assessments demonstrate considerable variability and many regions of the world lack access to trained pathologists. Though artificial intelligence (AI) promises to improve the access and quality of healthcare, the costs of image digitization in pathology and difficulties in deploying AI solutions remain as barriers to real-world use. Here we propose a cost-effective solution: the augmented reality microscope (ARM). The ARM overlays AI-based information onto the current view of the sample in real time, enabling seamless integration of AI into routine workflows. We demonstrate the utility of ARM in the detection of metastatic breast cancer and the identification of prostate cancer, with latency compatible with real-time use. We anticipate that the ARM will remove barriers towards the use of AI designed to improve the accuracy and efficiency of cancer diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41591-019-0539-7

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Research works printed but not linked: 1

  1. Russ, J. C. Computer-Assisted Microscopy: The Measurement and Analysis of Images (Springer Science & Business Media, 2012).

Cited by

See all 385

Metadata

Authors
Chen, P.-H. C., Gadepalli, K., MacDonald, R., Liu, Y., Kadowaki, S., Nagpal, K., Kohlberger, T., Dean, J., Corrado, G. S., Hipp, J. D., Mermel, C. H., & Stumpe, M. C.
Affiliations
Google (United States) (US)
Corresponding author
  • Mermel, Craig H.
  • Stumpe, Martin C.
Venue
Nature Medicine
Published
2019-08-12
Volume
25
Issue
9
Pages
1453-1457
ISSN
  • 1078-8956 (ISSN-L)
  • 1546-170X
OpenAlex
W2966884791
Cited by
342
References
33
Citations by year
2026: 16 · 2025: 87 · 2024: 41 · 2023: 43 · 2022: 39 · 2021: 57 · 2020: 45 · 2019: 13
FWCI
17.57
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Augmented Reality Applications
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
real-time artificial intelligence, cancer diagnosis, prostate cancer detection, digital pathology, histopathology image analysis, low-cost medical device
MeSH terms
Artificial Intelligence, Breast Neoplasms, Female, Humans, Male, Microscopy, Neoplasm Staging, Neoplasms, Prostatic Neoplasms

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An augmented reality microscope with real-time artificial intelligence integration for cancer diagnosis. https://app.cochat.ai/papers/10.1038/s41591-019-0539-7
The paper
Chen, P.-H. C., Gadepalli, K., MacDonald, R., Liu, Y., Kadowaki, S., Nagpal, K., Kohlberger, T., Dean, J., Corrado, G. S., Hipp, J. D., Mermel, C. H., & Stumpe, M. C. (2019). An augmented reality microscope with real-time artificial intelligence integration for cancer diagnosis. Nature Medicine. https://doi.org/10.1038/s41591-019-0539-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.