Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

A luminal unfolding microneedle injector for oral delivery of macromolecules

Open access
Abramson, Alex, Caffarel-Salvador, Ester, Soares, Vance, Minahan, Daniel, Tian, Ryan Yu, Lu, Xiaoya, Dellal, David, Gao, Yuan, Kim, Soyoung, Wainer, Jacob, Collins, Joy, Tamang, Siddartha, Hayward, Alison, Yoshitake, Tadayuki, Lee, Hsiang-Chieh, Fujimoto, James, Fels, Johannes, Frederiksen, Morten Revsgaard, Rahbek, Ulrik, Roxhed, Niclas, Langer, Robert, Traverso, Giovanni·2019·Nature Medicine

Abstract

Insulin and other injectable biologic drugs have transformed the treatment of patients suffering from diabetes1,2, yet patients and healthcare providers often prefer to use and prescribe less effective orally dosed medications3–5. Compared with subcutaneously administered drugs, oral formulations create less patient discomfort4, show greater chemical stability at high temperatures6, and do not generate biohazardous needle waste7. An oral dosage form for biologic medications is ideal; however, macromolecule drugs are not readily absorbed into the bloodstream through the gastrointestinal tract8. We developed an ingestible capsule, termed the luminal unfolding microneedle injector, which allows for the oral delivery of biologic drugs by rapidly propelling dissolvable drug-loaded microneedles into intestinal tissue using a set of unfolding arms. During ex vivo human and in vivo swine studies, the device consistently delivered the microneedles to the tissue without causing complete thickness perforations. Using insulin as a model drug, we showed that, when actuated, the luminal unfolding microneedle injector provided a faster pharmacokinetic uptake profile and a systemic uptake >10% of that of a subcutaneous injection over a 4-h sampling period. With the ability to load a multitude of microneedle formulations, the device can serve as a platform to orally deliver therapeutic doses of macromolecule drugs. A luminal unfolding microneedle injector device (LUMI) is engineered as a custom capsule capable of efficient biologic macromolecular drug delivery into the bloodstream via selective deployment within the gastrointestinal tract.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41591-019-0598-9

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 304

Metadata

Authors
Abramson, A., Caffarel-Salvador, E., Soares, V., Minahan, D., Tian, R. Y., Lu, X., Dellal, D., Gao, Y., Kim, S., Wainer, J., Collins, J., Tamang, S., Hayward, A., Yoshitake, T., Lee, H.-C., Fujimoto, J., Fels, J., Frederiksen, M. R., Rahbek, U., Roxhed, N., Langer, R., & Traverso, G.
Venue
Nature Medicine
Published
2019-10
Volume
25
Issue
10
Pages
1512-1518
ISSN
  • 1078-8956 (ISSN-L)
  • 1546-170X
OpenAlex
W2977826804
Cited by
304
References
42
FWCI
11.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A luminal unfolding microneedle injector for oral delivery of macromolecules. https://app.cochat.ai/papers/10.1038/s41591-019-0598-9
The paper
Abramson, A., Caffarel-Salvador, E., Soares, V., Minahan, D., Tian, R. Y., Lu, X., Dellal, D., Gao, Y., Kim, S., Wainer, J., Collins, J., Tamang, S., Hayward, A., Yoshitake, T., Lee, H.-C., Fujimoto, J., Fels, J., Frederiksen, M. R., Rahbek, U., . . . Traverso, G. (2019). A luminal unfolding microneedle injector for oral delivery of macromolecules. Nature Medicine. https://doi.org/10.1038/s41591-019-0598-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.