Screening and diagnosis of cardiovascular disease using artificial intelligence-enabled cardiac magnetic resonance imaging
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Cardiac magnetic resonance imaging (CMR) is the gold standard for cardiac function assessment and plays a crucial role in diagnosing cardiovascular disease (CVD). However, its widespread application has been limited by the heavy resource burden of CMR interpretation. Here, to address this challenge, we developed and validated computerized CMR interpretation for screening and diagnosis of 11 types of CVD in 9,719 patients. We propose a two-stage paradigm consisting of noninvasive cine-based CVD screening followed by cine and late gadolinium enhancement-based diagnosis. The screening and diagnostic models achieved high performance (area under the curve of 0.988 ± 0.3% and 0.991 ± 0.0%, respectively) in both internal and external datasets. Furthermore, the diagnostic model outperformed cardiologists in diagnosing pulmonary arterial hypertension, demonstrating the ability of artificial intelligence-enabled CMR to detect previously unidentified CMR features. This proof-of-concept study holds the potential to substantially advance the efficiency and scalability of CMR interpretation, thereby improving CVD screening and diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.74 · Cited by 24,513
Chen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2016) · arXiv · doi:10.48550/arxiv.1606.00915 · Cited by 22,392
Chen, L.-C., Papandreou, G., Kokkinos, I., Murphy, K., & Yuille, A. L. (2018) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2699184 · Cited by 22,392
nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation
Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J., & Maier-Hein, K. H. (2021) · Nature Methods · doi:10.1038/s41592-020-01008-z · Cited by 10,477
Quo Vadis, Action Recognition? A New Model and the Kinetics Dataset
Carreira, J., & Zisserman, A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.502 · Cited by 9,570
A Comprehensive Survey on Transfer Learning
Zhuang, F., Qi, Z., Duan, K., Xi, D., Zhu, Y., Zhu, H., Xiong, H., & He, Q. (2021) · Proceedings of the IEEE · doi:10.1109/jproc.2020.3004555 · Cited by 6,678 · cited 1×
“In terms of training, we loaded and froze the pretrained weights of each VST branch from different modalities using transfer learning 69 and only finetuned the last fully connected layers for feature aggregation.”
Arbitrary Style Transfer in Real-Time with Adaptive Instance Normalization
Huang, X., & Belongie, S. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.167 · Cited by 5,076
Caforio, A. L. P., Pankuweit, S., Arbustini, E., Basso, C., Gimeno-Blanes, J., Felix, S. B., Fu, M., Heliö, T., Heymans, S., Jahns, R., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht210 · Cited by 3,479
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Marcus, F. I., McKenna, W. J., Sherrill, D., Basso, C., Bauce, B., Bluemke, D. A., Calkins, H., Corrado, D., Cox, M. G. P. J., Daubert, J. P., et al. (2010) · Circulation · doi:10.1161/circulationaha.108.840827 · Cited by 2,676
Liu, Z., Ning, J., Cao, Y., Wei, Y., Zhang, Z., Lin, S., & Hu, H. (2021) · arXiv · doi:10.48550/arxiv.2106.13230 · Cited by 2,294
Liu, Z., Ning, J., Cao, Y., Wei, Y., Zhang, Z., Lin, S., & Hu, H. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.00320 · Cited by 2,294 · cited 3×
“Following the classic VST configuration 27 , we employed an AdamW optimizer using a cosine decay learning rate scheduler and 2.5 epochs of linear warmup.”
InfluentialCardiovascular Magnetic Resonance in Nonischemic Myocardial Inflammation
Ferreira, V. M., Schulz-Menger, J., Holmvang, G., Kramer, C. M., Carbone, I., Sechtem, U., Kindermann, I., Gutberlet, M., Cooper, L. T., Liu, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.072 · Cited by 2,059
LVIS: A Dataset for Large Vocabulary Instance Segmentation
Gupta, A., Dollar, P., & Girshick, R. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00550 · Cited by 1,274 · cited 1×
“To prevent the models from becoming biased toward one class, we balanced the training datasets for both screening and diagnostics using the ClassBalancedDataset sampling strategy 72 .”
Hypertension in low-and middle-income countries
Schutte, A. E., Srinivasapura Venkateshmurthy, N., Mohan, S., & Prabhakaran, D. (2021) · Circulation Research · doi:10.1161/circresaha.120.318729 · Cited by 460 · cited 1×
“Among these, over 75% of CVD deaths occur in low-and middle-income countries 2,3 .”
HIPAA and protecting health information in the 21st century
Cohen, I. G., & Mello, M. M. (2018) · JAMA · doi:10.1001/jama.2018.5630 · Cited by 273
Dvijotham, K., Winkens, J., Barsbey, M., Ghaisas, S., Stanforth, R., Pawlowski, N., Strachan, P., Ahmed, Z., Azizi, S., Bachrach, Y., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02437-x · Cited by 120
Cited by
Explainable Artificial Intelligence in Radiological Cardiovascular Imaging—A Systematic Review
Haupt, M., Maurer, M. H., & Thomas, R. P. (2025) · Diagnostics · doi:10.3390/diagnostics15111399 · Cited by 58
Turgut, Ö., Müller, P., Hager, P., Shit, S., Starck, S., Menten, M. J., Martens, E., & Rueckert, D. (2025) · Medical Image Analysis · doi:10.1016/j.media.2024.103451 · Cited by 22
Multimodal Deep Learning Model for Prediction of Prognosis in Central Nervous System Inflammation
Choi, B. K., Choi, Y., Jang, S., Ha, W.-S., Cho, S., Chang, K., Sohn, B., Kim, K. M., & Park, Y. R. (2025) · Brain Communications · doi:10.1093/braincomms/fcaf179 · Cited by 1
Metadata
- Authors
- Wang, Y.-R., Yang, K., Wen, Y., Wang, P., Hu, Y., Lai, Y., Wang, Y., Zhao, K., Tang, S., Zhang, A., Zhan, H., Lu, M., Chen, X., Yang, S., Dong, Z., Wang, Y., Liu, H., Zhao, L., Huang, L., Li, Y., Wu, L., Chen, Z., Luo, Y., Liu, D., Zhao, P., Lin, K., Wu, J. C., & Zhao, S.
- Venue
- Nature Medicine
- Published
- 2024-05
- Volume
- 30
- Issue
- 5
- Pages
- 1471-1480
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W4396862429
- Cited by
- 188
- References
- 21
- FWCI
- 43.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.