The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Modified aptamers enable quantitative sub-10-nm cellular DNA-PAINT imaging
Open accessAbstract
Although current implementations of super-resolution microscopy are technically approaching true molecular-scale resolution, this has not translated to imaging of biological specimens, because of the large size of conventional affinity reagents. Here we introduce slow off-rate modified aptamers (SOMAmers) as small and specific labeling reagents for use with DNA points accumulation in nanoscale topography (DNA-PAINT). To demonstrate the achievable resolution, specificity, and multiplexing capability of SOMAmers, we labeled and imaged both transmembrane and intracellular targets in fixed and live cells. Slow off-rate modified aptamer (SOMAmer) reagents are small and versatile probes for DNA-PAINT super-resolution microscopy that enable multiplexed, quantitative, and high-resolution imaging in fixed and live cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aptamer-Based Multiplexed Proteomic Technology for Biomarker Discovery
Gold, L., Ayers, D., Bertino, J., Bock, C., Bock, A., Brody, E. N., Carter, J., Dalby, A. B., Eaton, B. E., Fitzwater, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015004 · Cited by 1,754
Self-citationGupta, S., Hirota, M., Waugh, S. M., Murakami, I., Suzuki, T., Muraguchi, M., Shibamori, M., Ishikawa, Y., Jarvis, T. C., Carter, J. D., et al. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m113.532580 · Cited by 151
Self-citation
Cited by
Single-molecule methods in structural DNA nanotechnology
Platnich, C. M., Rizzuto, F. J., Cosa, G., & Sleiman, H. F. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00776h · Cited by 52
Live‐cell super‐resolution imaging of actin using LifeAct ‐14 with a PAINT ‐based approach
Bhaskar, H., Kleinjan, D., Oi, C., Gidden, Z., Rosser, S. J., Horrocks, M. H., & Regan, L. (2023) · Protein Science · doi:10.1002/pro.4558 · Cited by 12
Metadata
- Authors
- Strauss, S., Nickels, P. C., Strauss, M. T., Jimenez Sabinina, V., Ellenberg, J., Carter, J. D., Gupta, S., Janjic, N., & Jungmann, R.
- Venue
- Nature Methods
- Published
- 2018-08-20
- Volume
- 15
- Issue
- 9
- Pages
- 685-688
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2885894609
- Cited by
- 203
- References
- 2
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modified aptamers enable quantitative sub-10-nm cellular DNA-PAINT imaging. https://app.cochat.ai/papers/10.1038/s41592-018-0105-0
- The paper
- Strauss, S., Nickels, P. C., Strauss, M. T., Jimenez Sabinina, V., Ellenberg, J., Carter, J. D., Gupta, S., Janjic, N., & Jungmann, R. (2018). Modified aptamers enable quantitative sub-10-nm cellular DNA-PAINT imaging. Nature Methods. https://doi.org/10.1038/s41592-018-0105-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.