Modified aptamers enable quantitative sub-10-nm cellular DNA-PAINT imaging
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Although current implementations of super-resolution microscopy are technically approaching true molecular-scale resolution, this has not translated to imaging of biological specimens, because of the large size of conventional affinity reagents. Here we introduce slow off-rate modified aptamers (SOMAmers) as small and specific labeling reagents for use with DNA points accumulation in nanoscale topography (DNA-PAINT). To demonstrate the achievable resolution, specificity, and multiplexing capability of SOMAmers, we labeled and imaged both transmembrane and intracellular targets in fixed and live cells. Slow off-rate modified aptamer (SOMAmer) reagents are small and versatile probes for DNA-PAINT super-resolution microscopy that enable multiplexed, quantitative, and high-resolution imaging in fixed and live cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796
Deoxynucleoside phosphoramidites—A new class of key intermediates for deoxypolynucleotide synthesis
Beaucage, S. L., & Caruthers, M. H. (1981) · Tetrahedron Letters · doi:10.1016/s0040-4039(01)90461-7 · Cited by 1,993
Aptamer-Based Multiplexed Proteomic Technology for Biomarker Discovery
Gold, L., Ayers, D., Bertino, J., Bock, C., Bock, A., Brody, E. N., Carter, J., Dalby, A. B., Eaton, B. E., Fitzwater, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015004 · Cited by 1,754
Self-citationFeature point tracking and trajectory analysis for video imaging in cell biology
Sbalzarini, I. F., & Koumoutsakos, P. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.06.002 · Cited by 1,392
Nanometer resolution imaging and tracking of fluorescent molecules with minimal photon fluxes
Balzarotti, F., Eilers, Y., Gwosch, K. C., Gynnå, A. H., Westphal, V., Stefani, F. D., Elf, J., & Hell, S. W. (2017) · Science · doi:10.1126/science.aak9913 · Cited by 1,225
Multiplexed 3D cellular super-resolution imaging with DNA-PAINT and Exchange-PAINT
Jungmann, R., Avendaño, M. S., Woehrstein, J. B., Dai, M., Shih, W. M., & Yin, P. (2014) · Nature Methods · doi:10.1038/nmeth.2835 · Cited by 1,128
Self-citation
Cited by
Single-molecule localization microscopy
Lelek, M., Gyparaki, M. T., Beliu, G., Schueder, F., Griffié, J., Manley, S., Jungmann, R., Sauer, M., Lakadamyali, M., & Zimmer, C. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00038-x · Cited by 954
Self-citationRecent Progress in Aptamer Discoveries and Modifications for Therapeutic Applications
Ni, S., Zhuo, Z., Pan, Y., Yu, Y., Li, F., Liu, J., Wang, L., Wu, X., Li, D., Wan, Y., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c05750 · Cited by 589
The nucleolus functions as a phase-separated protein quality control compartment
Frottin, F., Schueder, F., Tiwary, S., Gupta, R., Körner, R., Schlichthaerle, T., Cox, J., Jungmann, R., Hartl, F. U., & Hipp, M. S. (2019) · Science · doi:10.1126/science.aaw9157 · Cited by 502
Self-citationUp to 100-fold speed-up and multiplexing in optimized DNA-PAINT
Strauss, S., & Jungmann, R. (2020) · Nature Methods · doi:10.1038/s41592-020-0869-x · Cited by 194
Self-citationIn vitro selection of aptamers and their applications
DeRosa, M. C., Lin, A., Mallikaratchy, P., McConnell, E. M., McKeague, M., Patel, R., & Shigdar, S. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00238-7 · Cited by 183
Strategies to manipulate the performance of aptamers in SELEX, post-SELEX and microenvironment
Qi, S., Duan, N., Khan, I. M., Dong, X., Zhang, Y., Wu, S., & Wang, Z. (2022) · Biotechnology Advances · doi:10.1016/j.biotechadv.2021.107902 · Cited by 164
Subcellular localization of biomolecules and drug distribution by high-definition ion beam imaging
Rovira-Clavé, X., Jiang, S., Bai, Y., Zhu, B., Barlow, G., Bhate, S., Coskun, A. F., Han, G., Ho, C.-M. K., Hitzman, C., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24822-1 · Cited by 73
Single-molecule methods in structural DNA nanotechnology
Platnich, C. M., Rizzuto, F. J., Cosa, G., & Sleiman, H. F. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00776h · Cited by 52
Live‐cell super‐resolution imaging of actin using LifeAct ‐14 with a PAINT ‐based approach
Bhaskar, H., Kleinjan, D., Oi, C., Gidden, Z., Rosser, S. J., Horrocks, M. H., & Regan, L. (2023) · Protein Science · doi:10.1002/pro.4558 · Cited by 12
Metadata
- Authors
- Strauss, S., Nickels, P. C., Strauss, M. T., Jimenez Sabinina, V., Ellenberg, J., Carter, J. D., Gupta, S., Janjic, N., & Jungmann, R.
- Venue
- Nature Methods
- Published
- 2018-08-20
- Volume
- 15
- Issue
- 9
- Pages
- 685-688
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2885894609
- Cited by
- 203
- References
- 26
- FWCI
- 10.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.