Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
The limited per-pixel bandwidth of most microscopy methods requires compromises between field of view, sampling density and imaging speed. This limitation constrains studies involving complex motion or fast cellular signaling, and presents a major bottleneck for high-throughput structural imaging. Here, we combine high-speed intensified camera technology with a versatile, reconfigurable and dramatically improved Swept, Confocally Aligned Planar Excitation (SCAPE) microscope design that can achieve high-resolution volumetric imaging at over 300 volumes per second and over 1.2 GHz pixel rates. We demonstrate near-isotropic sampling in freely moving Caenorhabditis elegans, and analyze real-time blood flow and calcium dynamics in the beating zebrafish heart. The same system also permits high-throughput structural imaging of mounted, intact, cleared and expanded samples. SCAPE 2.0's significantly lower photodamage compared to point-scanning techniques is also confirmed. Our results demonstrate that SCAPE 2.0 is a powerful, yet accessible imaging platform for myriad emerging high-speed dynamic and high-throughput volumetric microscopy applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the depth of field, corresponding to the maximum axial range with the optimal resolution, was smaller by a factor of 2 in our system than described in ref. 46.”
From The mesencephalic locomotor region recruits V2a reticulospinal neurons to drive forward locomotion in larval zebrafish (2023) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 1×
“The past two decades have seen dramatic improvements in techniques for molecular and genetic labelling of cellular function and structure in a wide array of model organisms 1–3 .”
Tracking whole-brain connectivity dynamics in the resting state
Allen, E. A., Damaraju, E., Plis, S. M., Erhardt, E. B., Eichele, T., & Calhoun, V. D. (2014) · Cerebral Cortex · doi:10.1093/cercor/bhs352 · Cited by 2,992 · cited 1×
“Correlation matrices between cells, within a ~30 second temporal sliding-window, were repeatedly k-means clustered to yield six cluster medians 24 (Figure 2d) representing six different patterns of correlation that the nervous system appears to switch between (Figure 2e).”
Globally optimal stitching of tiled 3D microscopic image acquisitions
Preibisch, S., Saalfeld, S., & Tomancak, P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp184 · Cited by 2,452
Imaging neural activity in worms, flies and mice with improved GCaMP calcium indicators
Tian, L., Hires, S. A., Mao, T., Huber, D., Chiappe, M. E., Chalasani, S. H., Petreanu, L., Akerboom, J., McKinney, S. A., Schreiter, E. R., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1398 · Cited by 1,967
Chen, F., Tillberg, P. W., & Boyden, E. S. (2015) · Science · doi:10.1126/science.1260088 · Cited by 1,501 · cited 2×
“The value of cleared and expanded tissues is truly unlocked when they are imaged in-toto, with sufficient isotropic resolution to resolve of the distribution, connectivity, molecular and genetic properties of cells 4,5 .”
Whole-brain functional imaging at cellular resolution using light-sheet microscopy
Ahrens, M. B., Orger, M. B., Robson, D. N., Li, J. M., & Keller, P. J. (2013) · Nature Methods · doi:10.1038/nmeth.2434 · Cited by 1,392 · cited 14×
“A field of view of approximately 700×500×75 µm was imaged permitting clear visualization of not only cell bodies, but also individual processes extending throughout the sample (see Supplementary Video 12 for a depth fly-through).”
InfluentialAdvanced CUBIC protocols for whole-brain and whole-body clearing and imaging
Susaki, E. A., Tainaka, K., Perrin, D., Yukinaga, H., Kuno, A., & Ueda, H. R. (2015) · Nature Protocols · doi:10.1038/nprot.2015.085 · Cited by 810
Transplantation and in vivo imaging of multilineage engraftment in zebrafish bloodless mutants
Traver, D., Paw, B. H., Poss, K. D., Penberthy, W. T., Lin, S., & Zon, L. I. (2003) · Nature Immunology · doi:10.1038/ni1007 · Cited by 800 · cited 1×
“Figure 3a–b shows SCAPE 2.0 imaging results obtained in 3 days post-fertilization (dpf) zebrafish embryos expressing GFP and DsRed in its endothelial cells and RBCs respectively 30,31 .”
Influential
Cited by
The connectome of an insect brain
Winding, M., Pedigo, B. D., Barnes, C. L., Patsolic, H. G., Park, Y., Kazimiers, T., Fushiki, A., Andrade, I. V., Khandelwal, A., Valdes-Aleman, J., et al. (2023) · Science · doi:10.1126/science.add9330 · Cited by 435
“Large-scale recording of functional activity in invertebrates (16, 19–21) and vertebrates (15, 17, 22, 23) demonstrates that neural computations occur across spatially dispersed brain regions, further motivating brain-wide circuit studies.”
BackgroundLight sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Wu, J., Lu, Z., Jiang, D., Guo, Y., Qiao, H., Zhang, Y., Zhu, T., Cai, Y., Zhang, X., Zhanghao, K., et al. (2021) · Cell · doi:10.1016/j.cell.2021.04.029 · Cited by 250
Wang, Z., Zhu, L., Zhang, H., Li, G., Yi, C., Li, Y., Yang, Y., Ding, Y., Zhen, M., Gao, S., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01058-x · Cited by 242
Sapoznik, E., Chang, B.-J., Huh, J., Ju, R. J., Azarova, E. V., Pohlkamp, T., Welf, E. S., Broadbent, D., Carisey, A. F., Stehbens, S. J., et al. (2020) · eLife · doi:10.7554/elife.57681 · Cited by 196
“Nevertheless, because the OPM described here adopts a galvanometer-based scan-descan optical geometry, camera framerate-limited imaging is possible (Kumar et al., 2018; Voleti et al., 2019; Yang et al., 2019).”
Metadata
- Authors
- Voleti, V., Patel, K. B., Li, W., Perez Campos, C., Bharadwaj, S., Yu, H., Ford, C., Casper, M. J., Yan, R. W., Liang, W., Wen, C., Kimura, K. D., Targoff, K. L., & Hillman, E. M. C.
- Affiliations
- Mortimer B. Zuckerman Mind Brain Behavior Institute (US)
- Columbia University (US)
- Nagoya City University (JP)
- NewYork–Presbyterian Hospital (US)
- Corresponding author
- Hillman, Elizabeth M. C.
- ORCID
- Venue
- Nature Methods
- Published
- 2019-09-27
- Volume
- 16
- Issue
- 10
- Pages
- 1054-1062
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- PMC
- PMC6885017
- OpenAlex
- W2976039826
- Cited by
- 320
- References
- 54
- Citations by year
- 2026: 22 · 2025: 46 · 2024: 53 · 2023: 53 · 2022: 56 · 2021: 50 · 2020: 36 · 2019: 4
- FWCI
- 17.80
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Methods (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Science Foundation (0801530, 2016201203)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Keywords
- volumetric microscopy, high-speed imaging, intensified camera, calcium dynamics, Caenorhabditis elegans, zebrafish heart, blood flow, photodamage, in vivo imaging, 3D microscopy
- MeSH terms
- Animals, Calcium, Heart, Microscopy, Zebrafish, Caenorhabditis elegans, Photons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0. https://app.cochat.ai/papers/10.1038/s41592-019-0579-4
- The paper
- Voleti, V., Patel, K. B., Li, W., Perez Campos, C., Bharadwaj, S., Yu, H., Ford, C., Casper, M. J., Yan, R. W., Liang, W., Wen, C., Kimura, K. D., Targoff, K. L., & Hillman, E. M. C. (2019). Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0. Nature Methods. https://doi.org/10.1038/s41592-019-0579-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.