Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
The limited per-pixel bandwidth of most microscopy methods requires compromises between field of view, sampling density and imaging speed. This limitation constrains studies involving complex motion or fast cellular signaling, and presents a major bottleneck for high-throughput structural imaging. Here, we combine high-speed intensified camera technology with a versatile, reconfigurable and dramatically improved Swept, Confocally Aligned Planar Excitation (SCAPE) microscope design that can achieve high-resolution volumetric imaging at over 300 volumes per second and over 1.2 GHz pixel rates. We demonstrate near-isotropic sampling in freely moving Caenorhabditis elegans, and analyze real-time blood flow and calcium dynamics in the beating zebrafish heart. The same system also permits high-throughput structural imaging of mounted, intact, cleared and expanded samples. SCAPE 2.0's significantly lower photodamage compared to point-scanning techniques is also confirmed. Our results demonstrate that SCAPE 2.0 is a powerful, yet accessible imaging platform for myriad emerging high-speed dynamic and high-throughput volumetric microscopy applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the depth of field, corresponding to the maximum axial range with the optimal resolution, was smaller by a factor of 2 in our system than described in ref. 46.”
From The mesencephalic locomotor region recruits V2a reticulospinal neurons to drive forward locomotion in larval zebrafish (2023) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 1×
“The past two decades have seen dramatic improvements in techniques for molecular and genetic labelling of cellular function and structure in a wide array of model organisms 1–3 .”
Tracking whole-brain connectivity dynamics in the resting state
Allen, E. A., Damaraju, E., Plis, S. M., Erhardt, E. B., Eichele, T., & Calhoun, V. D. (2014) · Cerebral Cortex · doi:10.1093/cercor/bhs352 · Cited by 2,992 · cited 1×
“Correlation matrices between cells, within a ~30 second temporal sliding-window, were repeatedly k-means clustered to yield six cluster medians 24 (Figure 2d) representing six different patterns of correlation that the nervous system appears to switch between (Figure 2e).”
Globally optimal stitching of tiled 3D microscopic image acquisitions
Preibisch, S., Saalfeld, S., & Tomancak, P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp184 · Cited by 2,452
Imaging neural activity in worms, flies and mice with improved GCaMP calcium indicators
Tian, L., Hires, S. A., Mao, T., Huber, D., Chiappe, M. E., Chalasani, S. H., Petreanu, L., Akerboom, J., McKinney, S. A., Schreiter, E. R., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1398 · Cited by 1,967
Chen, F., Tillberg, P. W., & Boyden, E. S. (2015) · Science · doi:10.1126/science.1260088 · Cited by 1,501 · cited 2×
“The value of cleared and expanded tissues is truly unlocked when they are imaged in-toto, with sufficient isotropic resolution to resolve of the distribution, connectivity, molecular and genetic properties of cells 4,5 .”
Whole-brain functional imaging at cellular resolution using light-sheet microscopy
Ahrens, M. B., Orger, M. B., Robson, D. N., Li, J. M., & Keller, P. J. (2013) · Nature Methods · doi:10.1038/nmeth.2434 · Cited by 1,392 · cited 14×
“A field of view of approximately 700×500×75 µm was imaged permitting clear visualization of not only cell bodies, but also individual processes extending throughout the sample (see Supplementary Video 12 for a depth fly-through).”
InfluentialAdvanced CUBIC protocols for whole-brain and whole-body clearing and imaging
Susaki, E. A., Tainaka, K., Perrin, D., Yukinaga, H., Kuno, A., & Ueda, H. R. (2015) · Nature Protocols · doi:10.1038/nprot.2015.085 · Cited by 810
Transplantation and in vivo imaging of multilineage engraftment in zebrafish bloodless mutants
Traver, D., Paw, B. H., Poss, K. D., Penberthy, W. T., Lin, S., & Zon, L. I. (2003) · Nature Immunology · doi:10.1038/ni1007 · Cited by 800 · cited 1×
“Figure 3a–b shows SCAPE 2.0 imaging results obtained in 3 days post-fertilization (dpf) zebrafish embryos expressing GFP and DsRed in its endothelial cells and RBCs respectively 30,31 .”
InfluentialSimultaneous whole-animal 3D imaging of neuronal activity using light-field microscopy
Prevedel, R., Yoon, Y.-G., Hoffmann, M., Pak, N., Wetzstein, G., Kato, S., Schrödel, T., Raskar, R., Zimmer, M., Boyden, E. S., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2964 · Cited by 799 · cited 1×
“Methods such as temporal focusing two-photon, light-field microscopy and dual-view inverted selective plane illumination microscopy (di-SPIM) light-sheet have yet to achieve the combined speed, field of view and resolution needed to capture the entire freely moving adult worm 20,21,22 .”
CLARITY for mapping the nervous system
Chung, K., & Deisseroth, K. (2013) · Nature Methods · doi:10.1038/nmeth.2481 · Cited by 747 · cited 1×
“The value of cleared and expanded tissues is truly unlocked when they are imaged in-toto, with sufficient isotropic resolution to resolve of the distribution, connectivity, molecular and genetic properties of cells 4,5 .”
Bouchard, M. B., Voleti, V., Mendes, C. S., Lacefield, C., Grueber, W. B., Mann, R. S., Bruno, R. M., & Hillman, E. M. C. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.323 · Cited by 566
Self-citationGlobal Brain Dynamics Embed the Motor Command Sequence of Caenorhabditis elegans
Kato, S., Kaplan, H. S., Schrödel, T., Skora, S., Lindsay, T. H., Yemini, E., Lockery, S., & Zimmer, M. (2015) · Cell · doi:10.1016/j.cell.2015.09.034 · Cited by 550 · cited 1×
“In keeping with previous studies 23 , neurons in the immobilized worm exhibited distinct patterns of calcium activity (Figure 2c), affording the chance to explore their dynamic “functional connectivity”.”
Steger, M., Diez, F., Dhekne, H. S., Lis, P., Nirujogi, R. S., Karayel, O., Tonelli, F., Martinez, T. N., Lorentzen, E., Pfeffer, S. R., et al. (2017) · eLife · doi:10.7554/elife.31012 · Cited by 482
Improved tools for the Brainbow toolbox
Cai, D., Cohen, K. B., Luo, T., Lichtman, J. W., & Sanes, J. R. (2013) · Nature Methods · doi:10.1038/nmeth.2450 · Cited by 426
Light-sheet microscopy for slide-free non-destructive pathology of large clinical specimens
Glaser, A. K., Reder, N. P., Chen, Y., McCarty, E. F., Yin, C., Wei, L., Wang, Y., True, L. D., & Liu, J. T. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0084 · Cited by 419 · cited 1×
“Inverted-SPIM geometries can better accommodate planar samples, but face immersion media and sample translation challenges, and cannot leverage the full working distance of their objective lenses 37,38 .”
Whole-brain calcium imaging with cellular resolution in freely behaving Caenorhabditis elegans
Nguyen, J. P., Shipley, F. B., Linder, A. N., Plummer, G. S., Liu, M., Setru, S. U., Shaevitz, J. W., & Leifer, A. M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1507110112 · Cited by 397
Allan, D. B., Caswell, T., Keim, N. C., van der Wel, C., & Verweij, R. W. (2015) · Figshare · doi:10.5281/zenodo.1213240 · Cited by 390
BigStitcher: reconstructing high-resolution image datasets of cleared and expanded samples
Hörl, D., Rojas Rusak, F., Preusser, F., Tillberg, P., Randel, N., Chhetri, R. K., Cardona, A., Keller, P. J., Harz, H., Leonhardt, H., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0501-0 · Cited by 383
Genetic and cellular analyses of zebrafish atrioventricular cushion and valve development
Beis, D., Bartman, T., Jin, S.-W., Scott, I. C., D'Amico, L. A., Ober, E. A., Verkade, H., Frantsve, J., Field, H. A., Wehman, A., et al. (2005) · Development · doi:10.1242/dev.01970 · Cited by 359 · cited 1×
“Figure 3a–b shows SCAPE 2.0 imaging results obtained in 3 days post-fertilization (dpf) zebrafish embryos expressing GFP and DsRed in its endothelial cells and RBCs respectively 30,31 .”
InfluentialOptically sectioned imaging by oblique plane microscopy
Dunsby, C. (2008) · Optics Express · doi:10.1364/oe.16.020306 · Cited by 348
Rapid 3D light-sheet microscopy with a tunable lens
Fahrbach, F. O., Voigt, F. F., Schmid, B., Helmchen, F., & Huisken, J. (2013) · Optics Express · doi:10.1364/oe.21.021010 · Cited by 347 · cited 15×
“A field of view of approximately 700×500×75 µm was imaged permitting clear visualization of not only cell bodies, but also individual processes extending throughout the sample (see Supplementary Video 12 for a depth fly-through).”
InfluentialBrain-wide 3D imaging of neuronal activity in Caenorhabditis elegans with sculpted light
Schrödel, T., Prevedel, R., Aumayr, K., Zimmer, M., & Vaziri, A. (2013) · Nature Methods · doi:10.1038/nmeth.2637 · Cited by 333 · cited 1×
“Methods such as temporal focusing two-photon, light-field microscopy and dual-view inverted selective plane illumination microscopy (di-SPIM) light-sheet have yet to achieve the combined speed, field of view and resolution needed to capture the entire freely moving adult worm 20,21,22 .”
Deconvolution-free Subcellular Imaging with Axially Swept Light Sheet Microscopy
Dean, K. M., Roudot, P., Welf, E. S., Danuser, G., & Fiolka, R. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.05.013 · Cited by 253 · cited 1×
“We also note that the uniformity and extent of SCAPE 2.0’s depth of field could be improved by adopting waist-scanning approaches 41 and adaptive optics to correct for sample-induced aberrations 42,43 .”
InfluentialPan-neuronal imaging in roaming Caenorhabditis elegans
Venkatachalam, V., Ji, N., Wang, X., Clark, C., Mitchell, J. K., Klein, M., Tabone, C. J., Florman, J., Ji, H., Greenwood, J., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1507109113 · Cited by 249 · cited 12×
“A larger field of view can be imaged at 10 VPS with single-color imaging, demonstrated in Supplementary Figure 3 and Supplementary Video 5 for a GFP-expressing worm in which cell bodies and dendritic processes can be clearly seen along the body wall.”
Influentialheart of glass Regulates the Concentric Growth of the Heart in Zebrafish
Mably, J. D., Burns, C. G., Chen, J.-N., Fishman, M. C., & Mohideen, M.-A. P. K. (2003) · Current Biology · doi:10.1016/j.cub.2003.11.055 · Cited by 244 · cited 1×
“100 VPS dual-color SCAPE 2.0 data was also acquired in 3-dpf zebrafish embryos expressing calcium-sensitive GCaMP and static DsRed in their myocardial cytosol and nuclei respectively 32,33 .”
InfluentialSPED Light Sheet Microscopy: Fast Mapping of Biological System Structure and Function
Tomer, R., Lovett-Barron, M., Kauvar, I., Andalman, A., Burns, V. M., Sankaran, S., Grosenick, L., Broxton, M., Yang, S., & Deisseroth, K. (2015) · Cell · doi:10.1016/j.cell.2015.11.061 · Cited by 239 · cited 15×
“SCAPE’s use of light-sheet illumination also provides significant phototoxicity and signal to noise benefits over point-scanning confocal microscopy, making it well-suited for high-speed, continuous imaging in-vivo and of sensitive samples 8–11 .”
InfluentialZebrafish model for human long QT syndrome
Arnaout, R., Ferrer, T., Huisken, J., Spitzer, K., Stainier, D. Y. R., Tristani-Firouzi, M., & Chi, N. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702724104 · Cited by 238 · cited 1×
“100 VPS dual-color SCAPE 2.0 data was also acquired in 3-dpf zebrafish embryos expressing calcium-sensitive GCaMP and static DsRed in their myocardial cytosol and nuclei respectively 32,33 .”
InfluentialHigh-resolution reconstruction of the beating zebrafish heart
Mickoleit, M., Schmid, B., Weber, M., Fahrbach, F. O., Hombach, S., Reischauer, S., & Huisken, J. (2014) · Nature Methods · doi:10.1038/nmeth.3037 · Cited by 229 · cited 1×
“Real-time cardiac imaging using an electrically tunable lenses (ETL) to maintain the system’s focus on a moving light sheet has been achieved, yet is challenging to synchronize at high speeds 10,29 .”
Long-Term Imaging of Caenorhabditis elegans Using Nanoparticle-Mediated Immobilization
Kim, E., Sun, L., Gabel, C. V., & Fang-Yen, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053419 · Cited by 221
Multi-immersion open-top light-sheet microscope for high-throughput imaging of cleared tissues
Glaser, A. K., Reder, N. P., Chen, Y., Yin, C., Wei, L., Kang, S., Barner, L. A., Xie, W., McCarty, E. F., Mao, C., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10534-0 · Cited by 203 · cited 1×
“Inverted-SPIM geometries can better accommodate planar samples, but face immersion media and sample translation challenges, and cannot leverage the full working distance of their objective lenses 37,38 .”
Light-Sheet Microscopy in Neuroscience
Hillman, E. M. C., Voleti, V., Li, W., & Yu, H. (2019) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-070918-050357 · Cited by 188
Self-citationEpi-illumination SPIM for volumetric imaging with high spatial-temporal resolution
Yang, B., Chen, X., Wang, Y., Feng, S., Pessino, V., Stuurman, N., Cho, N. H., Cheng, K. W., Lord, S. J., Xu, L., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0401-3 · Cited by 167 · cited 14×
“A field of view of approximately 700×500×75 µm was imaged permitting clear visualization of not only cell bodies, but also individual processes extending throughout the sample (see Supplementary Video 12 for a depth fly-through).”
InfluentialVaadia, R. D., Li, W., Voleti, V., Singhania, A., Hillman, E. M. C., & Grueber, W. B. (2019) · Current Biology · doi:10.1016/j.cub.2019.01.060 · Cited by 137
Self-citationWen, C., Miura, T., Voleti, V., Yamaguchi, K., Tsutsumi, M., Yamamoto, K., Otomo, K., Fujie, Y., Teramoto, T., Ishihara, T., et al. (2021) · eLife · doi:10.7554/elife.59187 · Cited by 133
Self-citationKumar, M., Kishore, S., Nasenbeny, J., McLean, D. L., & Kozorovitskiy, Y. (2018) · Optics Express · doi:10.1364/oe.26.013027 · Cited by 110 · cited 14×
“A field of view of approximately 700×500×75 µm was imaged permitting clear visualization of not only cell bodies, but also individual processes extending throughout the sample (see Supplementary Video 12 for a depth fly-through).”
InfluentialKirchmaier, B. C., Poon, K. L., Schwerte, T., Huisken, J., Winkler, C., Jungblut, B., Stainier, D. Y. R., & Brand, T. (2012) · Developmental Biology · doi:10.1016/j.ydbio.2012.01.015 · Cited by 76
Cell-accurate optical mapping across the entire developing heart
Weber, M., Scherf, N., Meyer, A. M., Panáková, D., Kohl, P. K., & Huisken, J. (2017) · eLife · doi:10.7554/elife.28307 · Cited by 57
Optically sectioned imaging by oblique plane microscopy
Kumar, S., Lin, Z., Lyon, A. R., MacLeod, K. T., & Dunsby, C. W. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.873471 · Cited by 56
Adaptive illumination based on direct wavefront sensing in a light-sheet fluorescence microscope
Wilding, D., Pozzi, P., Soloviev, O., Vdovin, G. V., & Verhaegen, M. (2016) · Optics Express · doi:10.1364/oe.24.024896 · Cited by 54 · cited 1×
“We also note that the uniformity and extent of SCAPE 2.0’s depth of field could be improved by adopting waist-scanning approaches 41 and adaptive optics to correct for sample-induced aberrations 42,43 .”
InfluentialHillman, E. M. C., Voleti, V., Patel, K., Li, W., Yu, H., Campos, C. P., Benezra, S. E., Bruno, R. M., & Galwaduge, P. T. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.03.007 · Cited by 54
Self-citation3D‐ultramicroscopy utilizing aspheric optics
Saghafi, S., Becker, K., Hahn, C., & Dodt, H. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201300048 · Cited by 51 · cited 1×
“…our first demonstration 7 was achieved through careful optimization of lenses, including using a Powell lens for more uniform light sheet formation 17 , a Plössl scan lens to reduce aberrations such as field curvature, maximization of detection numerical aperture (NA), sample-dependent adjustment…”
Wu, C., Ivanova, E., Cui, J., Lu, Q., & Pan, Z. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.1861-11.2011 · Cited by 50 · cited 1×
“6) 39 .”
Allan, D., Caswell, T. A., Keim, N. C., et al. (2018) · Figshare · doi:10.5281/zenodo.1226458 · Cited by 48
Zhang, L. J., Wen, J., Liang, X., Qi, R., Schoepf, U. J., Wichmann, J. L., Milliken, C. M., Chen, H., Kong, X., & Lu, G. (2015) · Radiology · doi:10.1148/radiol.2015150004 · Cited by 43
In vivo imaging of cardiac development and function in zebrafish using light sheet microscopy
Weber, M., & Huisken, J. (2015) · Swiss Medical Weekly · doi:10.4414/smw.2015.14227 · Cited by 43 · cited 1×
“Studies of the embryonic zebrafish heart can provide insights into the way that the vertebrate heart develops, as well as the influence of genetic and environmental factors on structural and functional cardiac development 25 .”
Denoising time-resolved microscopy image sequences with singular value thresholding
Furnival, T., Leary, R. K., & Midgley, P. A. (2016) · Ultramicroscopy · doi:10.1016/j.ultramic.2016.05.005 · Cited by 39
Visualizing Calcium Flux in Freely Moving Nematode Embryos
Ardiel, E. L., Kumar, A., Marbach, J., Christensen, R. P., Gupta, R., Duncan, W., Daniels, J. S., Stuurman, N., Colón‐Ramos, D. A., & Shroff, H. (2017) · Biophysical Journal · doi:10.1016/j.bpj.2017.02.035 · Cited by 32
Oblique light-sheet tomography: fast and high resolution volumetric imaging of mouse brainsPreprint
Narasimhan, A., Venkataraju, K. U., Mizrachi, J., Albeanu, D. F., & Osten, P. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/132423 · Cited by 32
Multi-purpose SLM-light-sheet microscope
Garbellotto, C., & Taylor, J. M. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.005419 · Cited by 23 · cited 1×
“We also note that the uniformity and extent of SCAPE 2.0’s depth of field could be improved by adopting waist-scanning approaches 41 and adaptive optics to correct for sample-induced aberrations 42,43 .”
InfluentialOptically gated beating-heart imaging
Taylor, J. M. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00481 · Cited by 20 · cited 1×
“Time-gated light-sheet techniques that build up a volumetric image by acquiring each plane across many beats 26,27 require periodicity and so cannot capture irregular arrhythmias or permit fully 4D particle tracking for red blood cell (RBC) flow analysis 28 .”
Zhang, L., Capilla, A., Song, W., Mostoslavsky, G., & Yi, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-08822-0 · Cited by 17 · cited 1×
“SCAPE is a single-objective oblique light sheet approach, which achieves high-speed volumetric imaging by sweeping both its excitation sheet and co-aligned detection planes along the x-direction without requiring any sample or objective lens motion (Figure 1a) 7,11–15 .”
3D + time blood flow mapping using SPIM-microPIV in the developing zebrafish heart
Žičkus, V., & Taylor, J. M. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.002418 · Cited by 16 · cited 1×
“Time-gated light-sheet techniques that build up a volumetric image by acquiring each plane across many beats 26,27 require periodicity and so cannot capture irregular arrhythmias or permit fully 4D particle tracking for red blood cell (RBC) flow analysis 28 .”
Wen, C., Miura, T., Fujie, Y., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/385567 · Cited by 10 · cited 1×
“A deep-learning based cell segmentation and tracking algorithm 34 was used to track the DsRed cardiomyocyte nuclei as fiducials on the heart wall, with 67 cells reliably tracked over multiple beats (see Supplementary Video 10).”
Self-citation
Cited by
The connectome of an insect brain
Winding, M., Pedigo, B. D., Barnes, C. L., Patsolic, H. G., Park, Y., Kazimiers, T., Fushiki, A., Andrade, I. V., Khandelwal, A., Valdes-Aleman, J., et al. (2023) · Science · doi:10.1126/science.add9330 · Cited by 435
“Large-scale recording of functional activity in invertebrates (16, 19–21) and vertebrates (15, 17, 22, 23) demonstrates that neural computations occur across spatially dispersed brain regions, further motivating brain-wide circuit studies.”
BackgroundLight sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Wu, J., Lu, Z., Jiang, D., Guo, Y., Qiao, H., Zhang, Y., Zhu, T., Cai, Y., Zhang, X., Zhanghao, K., et al. (2021) · Cell · doi:10.1016/j.cell.2021.04.029 · Cited by 250
Wang, Z., Zhu, L., Zhang, H., Li, G., Yi, C., Li, Y., Yang, Y., Ding, Y., Zhen, M., Gao, S., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01058-x · Cited by 242
Sapoznik, E., Chang, B.-J., Huh, J., Ju, R. J., Azarova, E. V., Pohlkamp, T., Welf, E. S., Broadbent, D., Carisey, A. F., Stehbens, S. J., et al. (2020) · eLife · doi:10.7554/elife.57681 · Cited by 196
“Nevertheless, because the OPM described here adopts a galvanometer-based scan-descan optical geometry, camera framerate-limited imaging is possible (Kumar et al., 2018; Voleti et al., 2019; Yang et al., 2019).”
Metadata
- Authors
- Voleti, V., Patel, K. B., Li, W., Perez Campos, C., Bharadwaj, S., Yu, H., Ford, C., Casper, M. J., Yan, R. W., Liang, W., Wen, C., Kimura, K. D., Targoff, K. L., & Hillman, E. M. C.
- Affiliations
- Mortimer B. Zuckerman Mind Brain Behavior Institute (US)
- Columbia University (US)
- Nagoya City University (JP)
- NewYork–Presbyterian Hospital (US)
- Corresponding author
- Hillman, Elizabeth M. C.
- ORCID
- Venue
- Nature Methods
- Published
- 2019-09-27
- Volume
- 16
- Issue
- 10
- Pages
- 1054-1062
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- PMC
- PMC6885017
- OpenAlex
- W2976039826
- Cited by
- 320
- References
- 54
- Citations by year
- 2026: 22 · 2025: 46 · 2024: 53 · 2023: 53 · 2022: 56 · 2021: 50 · 2020: 36 · 2019: 4
- FWCI
- 17.80
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature Methods (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Science Foundation (0801530, 2016201203)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Digital Holography and Microscopy
- Keywords
- volumetric microscopy, high-speed imaging, intensified camera, calcium dynamics, Caenorhabditis elegans, zebrafish heart, blood flow, photodamage, in vivo imaging, 3D microscopy
- MeSH terms
- Animals, Calcium, Heart, Microscopy, Zebrafish, Caenorhabditis elegans, Photons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.