In situ structure determination at nanometer resolution using TYGRESS
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The resolution of subtomogram averages calculated from cryo-electron tomograms (cryo-ET) of crowded cellular environments is often limited owing to signal loss in, and misalignment of, the subtomograms. By contrast, single-particle cryo-electron microscopy (SP-cryo-EM) routinely reaches near-atomic resolution of isolated complexes. We report a method called ‘tomography-guided 3D reconstruction of subcellular structures’ (TYGRESS) that is a hybrid of cryo-ET and SP-cryo-EM, and is able to achieve close-to-nanometer resolution of complexes inside crowded cellular environments. TYGRESS combines the advantages of SP-cryo-EM (images with good signal-to-noise ratio and contrast, as well as minimal radiation damage) and subtomogram averaging (three-dimensional alignment of macromolecules in a complex sample). Using TYGRESS, we determined the structure of the intact ciliary axoneme with up to resolution of 12 Å. These results reveal many structural details that were not visible by cryo-ET alone. TYGRESS is generally applicable to cellular complexes that are amenable to subtomogram averaging. The unique advantages of single-particle cryo-electron microscopy and cryo-electron tomography are combined in a method called TYGRESS, here applied to determine the structure of the intact ciliary axoneme at a resolution of 12 Å.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Environmental sensing through focal adhesions
Geiger, B., Spatz, J. P., & Bershadsky, A. D. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2593 · Cited by 2,543 · cited 1×
“However, similar to SP-cryo-EM, preferred orientation of structures, e.g. focal adhesion complexes 48 that are always oriented parallel to the EM grid, cannot be overcome by TYGRESS unless tilted HD images are included in the reconstruction.”
Rosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Inner lumen proteins stabilize doublet microtubules in cilia and flagella
Owa, M., Uchihashi, T., Yanagisawa, H.-A., Yamano, T., Iguchi, H., Fukuzawa, H., Wakabayashi, K.-I., Ando, T., & Kikkawa, M. (2019) · Nature Communications · doi:10.1038/s41467-019-09051-x · Cited by 140
Dymek, E. E., Lin, J., Fu, G., Porter, M. E., Nicastro, D., & Smith, E. F. (2019) · Molecular Biology of the Cell · doi:10.1091/mbc.e19-01-0063 · Cited by 61 · cited 2×
“…beam-induced sample motion that was not corrected by the whole-frame alignment in IMOD, sub-frame averages were calculated using frames 3–21, 22–40, 41–59, and 60–78 (the initial two frames were excluded due to in-frame blurring), and the following rounds of constrained alignment was done using…”
Self-citationMaheshwari, A., Obbineni, J. M., Bui, K. H., Shibata, K., Toyoshima, Y. Y., & Ishikawa, T. (2015) · Structure · doi:10.1016/j.str.2015.06.017 · Cited by 47
Cited by
Chen, Z., Shiozaki, M., Haas, K. M., Skinner, W. M., Zhao, S., Guo, C., Polacco, B. J., Yu, Z., Krogan, N. J., Lishko, P. V., et al. (2023) · Cell · doi:10.1016/j.cell.2023.09.017 · Cited by 82
Gui, L., Song, K., Tritschler, D., Bower, R., Yan, S., Dai, A., Augspurger, K., Sakizadeh, J., Grzemska, M., Ni, T., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1910960116 · Cited by 60
Self-citationMcCafferty, C. L., Pennington, E. L., Papoulas, O., Taylor, D. W., & Marcotte, E. M. (2023) · Communications Biology · doi:10.1038/s42003-023-04773-7 · Cited by 35
“To model the native arrangement of these dynein arms, we aligned the ODA structures into a subtomogram average determined from cryo-electron tomography of intact cilia axonemes (37) using ChimeraX (38).”
MethodFAP106 is an interaction hub for assembling microtubule inner proteins at the cilium inner junction
Shimogawa, M. M., Wijono, A. S., Wang, H., Zhang, J., Sha, J., Szombathy, N., Vadakkan, S., Pelayo, P., Jonnalagadda, K., Wohlschlegel, J., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40230-z · Cited by 18
Metadata
- Authors
- Song, K., Shang, Z., Fu, X., Lou, X., Grigorieff, N., & Nicastro, D.
- Venue
- Nature Methods
- Published
- 2019-11-25
- Volume
- 17
- Issue
- 2
- Pages
- 201-208
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2990465796
- Cited by
- 70
- References
- 5
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In situ structure determination at nanometer resolution using TYGRESS. https://app.cochat.ai/papers/10.1038/s41592-019-0651-0
- The paper
- Song, K., Shang, Z., Fu, X., Lou, X., Grigorieff, N., & Nicastro, D. (2020). In situ structure determination at nanometer resolution using TYGRESS. Nature Methods. https://doi.org/10.1038/s41592-019-0651-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.