The HCN channel voltage sensor undergoes a large downward motion during hyperpolarization
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Voltage-gated ion channels (VGICs) contain positively charged residues within the S4 helix of the voltage-sensing domain (VSD) that are displaced in response to changes in transmembrane voltage, promoting conformational changes that open the pore. Pacemaker hyperpolarization-activated cyclic nucleotide-gated (HCN) channels are unique among VGICs because their open probability is increased by membrane hyperpolarization rather than depolarization. Here we measured the precise movement of the S4 helix of a sea urchin HCN channel using transition metal ion fluorescence resonance energy transfer (tmFRET). We show that the S4 undergoes a substantial (~10 Å) downward movement in response to membrane hyperpolarization. Furthermore, by applying distance constraints determined from tmFRET experiments to Rosetta modeling, we reveal that the carboxy-terminal part of the S4 helix exhibits an unexpected tilting motion during hyperpolarization activation. These data provide a long-sought glimpse of the hyperpolarized state of a functioning VSD and also a framework for understanding the dynamics of reverse gating in HCN channels. Transition metal FRET and Rosetta modeling reveal that the S4 helix in the voltage-sensing domain of the HCN channel moves downward and its carboxy-terminal portion tilts during hyperpolarization activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles and Biophysical Applications of Lanthanide-Based Probes
Selvin, P. R. (2002) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.31.101101.140927 · Cited by 549
Cited by
Santoro, B., & Shah, M. M. (2020) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010919-023356 · Cited by 108
Ih from synapses to networks: HCN channel functions and modulation in neurons
Combe, C. L., & Gasparini, S. (2021) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2021.06.002 · Cited by 101
Voltage sensor conformations induced by LQTS-associated mutations in hERG potassium channels
(2025) · doi:10.1038/s41467-025-62472-9 · Cited by 5
Voltage Sensor Conformations Induced by LQTS-associated Mutations in hERG Potassium Channels
Chan, A. N., Quach, C. D., Handlin, L. J., Lessie, E. N., Tajkhorshid, E., & Dai, G. (2024) · doi:10.1101/2024.05.17.594747 · Cited by 5
Self-citation
Metadata
- Authors
- Dai, G., Aman, T. K., DiMaio, F., & Zagotta, W. N.
- Venue
- Nature Structural & Molecular Biology
- Published
- 2019-07-08
- Volume
- 26
- Issue
- 8
- Pages
- 686-694
- ISSN
- 1545-9985 (ISSN-L)
- 1545-9993
- OpenAlex
- W2953726413
- Cited by
- 64
- References
- 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The HCN channel voltage sensor undergoes a large downward motion during hyperpolarization. https://app.cochat.ai/papers/10.1038/s41594-019-0259-1
- The paper
- Dai, G., Aman, T. K., DiMaio, F., & Zagotta, W. N. (2019). The HCN channel voltage sensor undergoes a large downward motion during hyperpolarization. Nature Structural & Molecular Biology. https://doi.org/10.1038/s41594-019-0259-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.