Collection, pre-processing and on-the-fly analysis of data for high-resolution, single-particle cryo-electron microscopy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The dramatic growth in the use of cryo-electron microscopy (cryo-EM) to generate high-resolution structures of macromolecular complexes has changed the landscape of structural biology. The majority of structures deposited in the Electron Microscopy Data Bank (EMDB) at higher than 4-Å resolution were collected on Titan Krios microscopes. Although the pipeline for single-particle data collection is becoming routine, there is much variation in how sessions are set up. Furthermore, when collection is under way, there are a range of approaches for efficiently moving and pre-processing these data. Here, we present a standard operating procedure for single-particle data collection with Thermo Fisher Scientific EPU software, using the two most common direct electron detectors (the Thermo Fisher Scientific Falcon 3 (F3EC) and the Gatan K2), as well as a strategy for structuring these data to enable efficient pre-processing and on-the-fly monitoring of data collection. This protocol takes 3–6 h to set up a typical automated data collection session. This protocol describes a pipeline for data collection, pre-processing and on-the-fly analysis for single-particle cryo-electron microscopy using EPU software and two direct electron detectors: the Thermo Fisher Scientific Falcon 3 and the Gatan K2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kühlbrandt, W. (2014) · Science · doi:10.1126/science.1251652 · Cited by 1,325
Cited by
New tools for automated cryo-EM single-particle analysis in RELION-4.0
Kimanius, D., Dong, L., Sharov, G., Nakane, T., & Scheres, S. H. W. (2021) · Biochemical Journal · doi:10.1042/bcj20210708 · Cited by 1,086
Single-particle cryo-EM at atomic resolution
Nakane, T., Kotecha, A., Sente, A., McMullan, G., Masiulis, S., Brown, P. M. G. E., Grigoras, I. T., Malinauskaite, L., Malinauskas, T., Miehling, J., et al. (2020) · Nature · doi:10.1038/s41586-020-2829-0 · Cited by 868
Bloch, J. S., Mukherjee, S., Kowal, J., Filippova, E. V., Niederer, M., Pardon, E., Steyaert, J., Kossiakoff, A. A., & Locher, K. P. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2115435118 · Cited by 114
Metabolic control of BRISC-SHMT2 assembly regulates immune signalling
Walden, M., Tian, L., Ross, R. L., Sykora, U. M., Byrne, D. P., Hesketh, E. L., Masandi, S. K., Cassel, J., George, R., Ault, J. R., et al. (2019) · Nature · doi:10.1038/s41586-019-1232-1 · Cited by 85
Self-citationMechanism of glycogen synthase inactivation and interaction with glycogenin
Marr, L., Biswas, D., Daly, L. A., Browning, C., Vial, S. C. M., Maskell, D. P., Hudson, C., Bertrand, J. A., Pollard, J., Ranson, N. A., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31109-6 · Cited by 47
Self-citation
Metadata
- Authors
- Thompson, R. F., Iadanza, M. G., Hesketh, E. L., Rawson, S., & Ranson, N. A.
- Venue
- Nature Protocols
- Published
- 2018-11-28
- Volume
- 14
- Issue
- 1
- Pages
- 100-118
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W2902560198
- Cited by
- 127
- References
- 1
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Collection, pre-processing and on-the-fly analysis of data for high-resolution, single-particle cryo-electron microscopy. https://app.cochat.ai/papers/10.1038/s41596-018-0084-8
- The paper
- Thompson, R. F., Iadanza, M. G., Hesketh, E. L., Rawson, S., & Ranson, N. A. (2019). Collection, pre-processing and on-the-fly analysis of data for high-resolution, single-particle cryo-electron microscopy. Nature Protocols. https://doi.org/10.1038/s41596-018-0084-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.