The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Rapid online buffer exchange for screening of proteins, protein complexes and cell lysates by native mass spectrometry
Open accessPublished version of a preprint
Abstract
It is important to assess the identity and purity of proteins and protein complexes during and after protein purification to ensure that samples are of sufficient quality for further biochemical and structural characterization, as well as for use in consumer products, chemical processes and therapeutics. Native mass spectrometry (nMS) has become an important tool in protein analysis due to its ability to retain non-covalent interactions during measurements, making it possible to obtain protein structural information with high sensitivity and at high speed. Interferences from the presence of non-volatiles are typically alleviated by offline buffer exchange, which is time-consuming and difficult to automate. We provide a protocol for rapid online buffer exchange (OBE) nMS to directly screen structural features of pre-purified proteins, protein complexes or clarified cell lysates. In the liquid chromatography coupled to mass spectrometry (LC-MS) approach described in this protocol, samples in MS-incompatible conditions are injected onto a short size-exclusion chromatography column. Proteins and protein complexes are separated from small molecule non-volatile buffer components using an aqueous, non-denaturing mobile phase. Eluted proteins and protein complexes are detected by the mass spectrometer after electrospray ionization. Mass spectra can inform regarding protein sample purity and oligomerization, and additional tandem mass spectra can help to further obtain information on protein complex subunits. Information obtained by OBE nMS can be used for fast (<5 min) quality control and can further guide protein expression and purification optimization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, online size exclusion chromatography (SEC) has been used for the rapid online desalting of antibodies and protein complexes [77].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [77]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ExPASy: the proteomics server for in-depth protein knowledge and analysis
Gasteiger, E. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg563 · Cited by 5,602
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1 · Cited by 1,152
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Protein production and purification
Biologiques, A. E. F. D. M., Facility, O. P. P., Initiative, R. S. G., & SPINE2-Complexes (2008) · Nature Methods · doi:10.1038/nmeth.f.202 · Cited by 919
Analysis of protein complexes using mass spectrometry
Gingras, A., Gstaiger, M., Raught, B., & Aebersold, R. H. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2208 · Cited by 727
Probing conformational changes in proteins by mass spectrometry
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00180a074 · Cited by 652
Mechanisms of Protein Stabilization and Prevention of Protein Aggregation by Glycerol
Vagenende, V., Yap, M. G. S., & Trout, B. L. (2009) · Biochemistry · doi:10.1021/bi900649t · Cited by 556
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 420
Cited by
Sorted by citations
De novo design of protein logic gates
Chen, Z., Kibler, R. D., Hunt, A. C., Büsch, F., Pearl, J. R., Jia, M., VanAernum, Z. L., Wicky, B. I. M., Dods, G., Liao, H., et al. (2020) · Science · doi:10.1126/science.aay2790 · Cited by 211
Self-citationProtein–Small Molecule Interactions in Native Mass Spectrometry
Bennett, J. L., Nguyen, G. T. H., & Donald, W. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00293 · Cited by 161
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146
Native Mass Spectrometry: Recent Progress and Remaining Challenges
Karch, K. R., Snyder, D. T., Harvey, S. R., & Wysocki, V. H. (2022) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-092721-085421 · Cited by 149
Self-citation
Metadata
- Authors
- VanAernum, Z. L., Busch, F., Jones, B. J., Jia, M., Chen, Z., Boyken, S. E., Sahasrabuddhe, A., Baker, D., & Wysocki, V. H.
- Affiliations
- The Ohio State University (US)
- California Institute of Technology (US)
- University of Washington (US)
- Amgen (United States) (US)
- Howard Hughes Medical Institute (US)
- Corresponding author
- Wysocki, Vicki H.
- ORCID
- Venue
- Nature Protocols
- Published
- 2020-01-31
- Volume
- 15
- Issue
- 3
- Pages
- 1132-1157
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- PMC
- PMC7203678
- OpenAlex
- W3004074111
- Cited by
- 169
- References
- 61
- Citations by year
- 2026: 21 · 2025: 19 · 2024: 36 · 2023: 26 · 2022: 23 · 2021: 24 · 2020: 17
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- Locations
- Nature Protocols (publishedVersion)
- ChemRxiv (acceptedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion, cc-by-nc-nd)
- Royal College of Surgeons in Ireland (submittedVersion, cc-by-nc-nd)
- Funders
- U.S. Department of Health & Human Services | National Institutes of Health (P41 GM128577, S10 OD018507)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein purification and stability
- Keywords
- native mass spectrometry, protein quality control, protein complexes, cell lysate, size exclusion chromatography, protein oligomerization, protein purification, tandem mass spectrometry, sample preparation
- MeSH terms
- Buffers, Chemistry Techniques, Analytical, Chromatography, Gel, Proteins, Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review